CES VASCULAR OCCLUSION SYSTEM
Device Facts
| Record ID | K964367 |
|---|---|
| Device Name | CES VASCULAR OCCLUSION SYSTEM |
| Applicant | Cordis Neurovascular, Inc. |
| Product Code | HCG · Neurology |
| Decision Date | Jan 30, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 882.5950 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
CES Occlusion Devices may be used to reduce or block the rate of blood flow in small or tapering vessels. They are indicated for use in the interventional radiologic management of arteriovenous malformations and other vascular lesions of the brain, spinal cord and spine when devascularization prior to definitive surgical resection is desired.
Device Story
CES Vascular Occlusion System consists of occlusion coils and coil pusher; used to reduce/block blood flow in small/tapering vessels. Operated by interventional radiologists; deployed via catheter into target vasculature (brain, spinal cord, spine). Coils provide mechanical occlusion to devascularize lesions prior to surgical resection. System design and function analogous to existing embolic coil technologies.
Clinical Evidence
Bench testing only; biocompatibility testing successfully performed on occlusion device and coil pusher.
Technological Characteristics
System includes occlusion coils and coil pusher. Materials biocompatibility verified. Mechanical occlusion principle. No software or electronic components.
Indications for Use
Indicated for patients requiring reduction or blockage of blood flow in small or tapering vessels, specifically for interventional radiologic management of arteriovenous malformations and vascular lesions of the brain, spinal cord, and spine prior to surgical resection.
Regulatory Classification
Identification
A neurovascular embolization device is an intravascular implant intended to permanently occlude blood flow to cerebral aneurysms and cerebral ateriovenous malformations. This does not include cyanoacrylates and other embolic agents, which act by polymerization or precipitation. Embolization devices used in other vascular applications are also not included in this classification, see § 870.3300.
Special Controls
*Classification.* Class II (special controls.) The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Vascular and Neurovascular Embolization Devices.” For availability of this guidance document, see § 882.1(e).
Predicate Devices
- Target Therapeutics Fibered Helical Coils (K901721)
- Cook, Inc. Hilal Embolization Microcoil (K901337)
- Target Therapeutics Helical Coils and Coil Pusher (K891688)
- Cordis Endovascular Systems (CES), Inc. Instinct® Steerable Guidewire (K930982)
Related Devices
- K972881 — CES VASCULAR OCCLUSION SYSTEM · Cordis Neurovascular, Inc. · Jun 4, 1998
- K073442 — MICRUS MICROCOIL SYSTEMS · Micrus Endovascular Corporation · Feb 26, 2008
- K151760 — Barricade Embolization Coil System · Blockade Medical · Jul 27, 2015
- K173614 — Penumbra Coil 400, Ruby Coil System, POD System · Penumbra, Inc. · Apr 17, 2018
- K071962 — VASCULAR OCCLUSION SYSTEM (TRUFILL PUSHABLE COILS AND TRUPUSH COIL PUSHER) · Cordis Neurovascular, Inc. · Sep 26, 2007