SPEC T.E.N.S. PREWIRED REPOSITIONABLE TENS ELECTRODE - MODIFY
Device Facts
| Record ID | K962910 |
|---|---|
| Device Name | SPEC T.E.N.S. PREWIRED REPOSITIONABLE TENS ELECTRODE - MODIFY |
| Applicant | Uni-Patch, Inc. |
| Product Code | GZJ · Neurology |
| Decision Date | Sep 5, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 882.5890 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
Uni-Patch considers their Transcutaneous Electrical Nerve Stimulation (TENS) and Muscle Stimulation (NMES/FES) Electrodes to be as safe and effective as the Axelgaard Manufacturing Company Pals® Plus Reusable Neurostimulation Electrode and the LMI Spec T.E.N.S. Repositionable Pin-Type TENS Electrode (K894042A) with Promeon RG-60 Series gel of which were previously found to be substantially equivalent via a 510(k) Premarket Notification.
Device Story
Repositionable electrodes for TENS, NMES, and FES; utilize RG-60 series conductive gel for skin adhesion; interface between electrical stimulator and patient skin; used in clinical or home settings; operated by patients or clinicians; function by delivering electrical current to target tissue; effectiveness verified via impedance measurement at 1K-Hz; safety verified via biocompatibility testing of gel.
Clinical Evidence
Bench testing only. Biocompatibility testing performed per Tripartite Biocompatibility Guidance (Cytotoxicity, Buehler Patch Test, Repeat Insult Patch Test, Primary Skin Irritation). Effectiveness established via comparative impedance testing at 1K-Hz against predicate electrodes.
Technological Characteristics
Repositionable cutaneous electrodes; RG-60 series conductive gel; impedance-based performance; short-term skin contact; biocompatibility per Tripartite Guidance.
Indications for Use
Indicated for use as electrodes for Transcutaneous Electrical Nerve Stimulation (TENS) and Neuromuscular Electrical Stimulation (NMES/FES) for patients requiring electrical stimulation therapy.
Regulatory Classification
Identification
A transcutaneous electrical nerve stimulator for pain relief is a device used to apply an electrical current to electrodes on a patient's skin to treat pain.
Predicate Devices
- Axelgaard Manufacturing Company Pals® Plus Reusable Neurostimulation Electrode
- LMI Spec T.E.N.S. Repositionable Pin-Type TENS Electrode (K894042A)
Related Devices
- K961141 — EASY FLEX TENS/FES/MNS ELECTRODES 2 ROUND MODEL 8200/2X2 MODEL 8220 · Uni-Patch, Inc. · May 10, 1996
- K180773 — Reusable and Self-Adhesive Electrodes · Shaoxing Dongzhi Electrical Technology Co., Ltd. · May 22, 2018
- K212191 — Adhesive Electrodes · Voncare Medical Device Co., Ltd. · Oct 6, 2021
- K131720 — HIVOX SELF ADHESIVE ELECTRODE GEL PADS · Hivox Biotek, Inc. · Jul 25, 2014
- K152815 — Mailuokang Self-adhesive Electrode · Shenzhen Mailuokang Technology Co., Ltd. · Mar 8, 2016