MYF · Enzyme Linked Immunosorbent Assay, Herpes Simplex Virus, Hsv-2

Microbiology · 21 CFR 866.3305 · Class 2

Overview

Product CodeMYF
Device NameEnzyme Linked Immunosorbent Assay, Herpes Simplex Virus, Hsv-2
Regulation21 CFR 866.3305
Device ClassClass 2
Review PanelMicrobiology

Identification

Herpes simplex virus serological assays are devices that consist of antigens and antisera used in various serological tests to identify antibodies to herpes simplex virus in serum. Additionally, some of the assays consist of herpes simplex virus antisera conjugated with a fluorescent dye (immunofluorescent assays) used to identify herpes simplex virus directly from clinical specimens or tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of diseases caused by herpes simplex viruses and provides epidemiological information on these diseases. Herpes simplex viral infections range from common and mild lesions of the skin and mucous membranes to a severe form of encephalitis (inflammation of the brain). Neonatal herpes virus infections range from a mild infection to a severe generalized disease with a fatal outcome.

Classification Rationale

Class II (special controls). The device is classified as class II (special controls). The special control for the device is FDA's revised guidance document entitled “Class II Special Controls Guidance Document: Herpes Simplex Virus Types 1 and 2 Serological Assays.” For availability of the guidance revised document, see § 866.1(e).

Special Controls

*Classification.* Class II (special controls). The device is classified as class II (special controls). The special control for the device is FDA's revised guidance document entitled “Class II Special Controls Guidance Document: Herpes Simplex Virus Types 1 and 2 Serological Assays.” For availability of the guidance revised document, see § 866.1(e).

Recent Cleared Devices (10 of 10)

RecordDevice NameApplicantDecision DateDecision
K243575ARCHITECT HSV-2 IgG, ARCHITECT HSV-2 IgG Calibrator, ARCHITECT HSV-2 IgG ControlsBiokit, S.A.Feb 12, 2025SESE
K220924Elecsys HSV-2 IgG (08948887160)Roche DiagnosticsOct 12, 2022SESE
K181514SeraQuest HSV Type 2 Specific IgGQuest International, Inc.Jun 13, 2019SESE
K181334ADVIA Centaur Herpes-2 IgGBiokit, S.A.Aug 23, 2018SESE
K152353SeraQuest HSV Type 2 Specific IgGQuest International, Inc.May 13, 2016SESE
K103603ZEUS ELISA HSV GG-2 IGG TEST SYSTEMZeus Scientific, Inc.May 20, 2011SESE
K081687LIAISON HSV-2 TYPE SPECIFIC IGG ASSAY, CONTROL HSV-2 IGGDiaSorin, Inc.Nov 10, 2008SESE
K061239EUROIMMUN ANTI-HSV-2 ELISA (IGG) AND ANTI-HSV-1 ELISA (IGG) KITEuroimmun Us, LLCJun 28, 2007SESE
K033106CAPTIA HSV 2 IGG TYPE SPECIFIC ELISA KITTrinity Biotech USAJul 13, 2004SESE
K993724HSV-2 ELISA IGG, MODEL EL0920GMrl DiagnosticsFeb 1, 2000SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...