Cytokeratin Fragments 21-1 Eia Kit

Page Type
Product Code
Definition
The CYFRA 21-1 EIA kit is intended for the quantitative determination of soluble cytokeratin 19 fragments in human serum. The assay is to be used as an aid in monitoring disease progression during the course of disease and treatment in lung cancer patients. Serial testing for patient CYFRA 21-1 assay values should be used in conjunction with other clinical methods used for monitoring lung cancer.
Physical State
plastic microtiter plate, plate reader system
Technical Method
Enzyme immunoassay to quantify soluble cytokeratin 19 in human serum.
Target Area
Patient serum
Regulation Medical Specialty
Immunology
Review Panel
Immunology
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
866.6010
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Third Party Eligible

CFR § 866.6010 Tumor-associated antigen immunological test system

§ 866.6010 Tumor-associated antigen immunological test system.

(a) Identification. A tumor-associated antigen immunological test system is a device that consists of reagents used to qualitatively or quantitatively measure, by immunochemical techniques, tumor-associated antigens in serum, plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease.

(b) Classification. Class II (special controls). Tumor markers must comply with the following special controls: (1) A guidance document entitled “Guidance Document for the Submission of Tumor Associated Antigen Premarket Notifications (510(k)s) to FDA,” and (2) voluntary assay performance standards issued by the National Committee on Clinical Laboratory Standards.

[62 FR 66005, Dec. 17, 1997]

Cytokeratin Fragments 21-1 Eia Kit

Page Type
Product Code
Definition
The CYFRA 21-1 EIA kit is intended for the quantitative determination of soluble cytokeratin 19 fragments in human serum. The assay is to be used as an aid in monitoring disease progression during the course of disease and treatment in lung cancer patients. Serial testing for patient CYFRA 21-1 assay values should be used in conjunction with other clinical methods used for monitoring lung cancer.
Physical State
plastic microtiter plate, plate reader system
Technical Method
Enzyme immunoassay to quantify soluble cytokeratin 19 in human serum.
Target Area
Patient serum
Regulation Medical Specialty
Immunology
Review Panel
Immunology
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
866.6010
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Third Party Eligible

CFR § 866.6010 Tumor-associated antigen immunological test system

§ 866.6010 Tumor-associated antigen immunological test system.

(a) Identification. A tumor-associated antigen immunological test system is a device that consists of reagents used to qualitatively or quantitatively measure, by immunochemical techniques, tumor-associated antigens in serum, plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease.

(b) Classification. Class II (special controls). Tumor markers must comply with the following special controls: (1) A guidance document entitled “Guidance Document for the Submission of Tumor Associated Antigen Premarket Notifications (510(k)s) to FDA,” and (2) voluntary assay performance standards issued by the National Committee on Clinical Laboratory Standards.

[62 FR 66005, Dec. 17, 1997]