FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
CFR Sub-Part
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart C—Cardiovascular Monitoring Devices
CFR Sub-Part
Subpart C—General Hospital and Personal Use Monitoring Devices
CFR Sub-Part
Subpart D—Pathology Instrumentation and Accessories
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—General Hospital and Personal Use Therapeutic Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Subpart G—General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
FLG
Cleaner, Ultrasonic, Medical Instrument
1
Product Code
FLH
Washer Of Body Waste Receptacles
1
Product Code
FLI
Cabinet, Ethylene-Oxide Gas Aerator
2
Product Code
BRT
Restraint, Patient, Conductive
1
Product Code
BYY
Tube, Aspirating, Flexible, Connecting
2
Product Code
BYZ
Trap, Sterile Specimen
2
Product Code
CBC
Bottle, Collection And Trap, Breathing System (Uncalibrated)
2
Product Code
CBD
Bottle, Collection, Breathing System (Calibrated)
2
Product Code
FLE
Sterilizer, Steam
2
Product Code
FLF
Sterilizer, Ethylene-Oxide Gas
2
Product Code
FMA
Depressor, Tongue, Non-Surgical
1
Product Code
FMC
Patient Examination Glove
1
Product Code
FME
Gown, Examination
1
Product Code
FML
Chair, Blood Donor
1
Product Code
FMP
Protector, Skin Pressure
1
Product Code
FMQ
Restraint, Protective
1
Product Code
FMR
Device, Transfer, Patient, Manual
1
Product Code
FMW
Cover, Mattress (Medical Purposes)
1
Product Code
FNP
Urinal
1
Product Code
FNS
Ring Cutter
1
Product Code
FNY
Basin, Emesis
1
Product Code
FOA
Board, Cardiopulmonary
1
Product Code
FOB
Bedpan
1
Product Code
FOX
Stand, Infusion
1
Product Code
FPF
Bottle, Hot/Cold Water
1
Product Code
FPO
Stretcher, Wheeled
2
Product Code
FPP
Stretcher, Hand-Carried
1
Product Code
FPS
Board, Bed
1
Product Code
FRA
Purifier, Air, Ultraviolet, Medical
2
Product Code
FRG
Wrap, Sterilization
2
Product Code
FRJ
Chair, Geriatric
1
Product Code
FRK
Chair, Examination And Treatment
1
Product Code
FRZ
Device, Patient Transfer, Powered
2
Product Code
GAZ
Tubing, Noninvasive
2
Product Code
GCX
Apparatus, Suction, Operating-Room, Wall Vacuum Powered
2
Product Code
JOK
Scissors, Medical, Disposable
1
Product Code
JOL
Catheter And Tip, Suction
2
Product Code
KCT
Sterilization Wrap Containers, Trays, Cassettes & Other Accessories
2
Product Code
KDP
Regulator, Vacuum
2
Product Code
KDQ
Bottle, Collection, Vacuum
2
Product Code
KIA
Cover, Cast
1
Product Code
KME
Bedding, Disposable, Medical
1
Product Code
K
04
2145
READY-HEAT BLANKET
1
Cleared 510(K)
K
94
4953
OREX MEDICAL BEDDING
1
Cleared 510(K)
K
93
3636
DISPOSE-A-SHEET
1
Cleared 510(K)
K
93
2539
DOCTOR DOWN --RESCUE WRAP
1
Cleared 510(K)
K
92
2143
AMERICAN BURN SHEET
1
Cleared 510(K)
K
91
5303
FOIL BABY BUNTING
1
Cleared 510(K)
K
91
2257
CHEM-SLEEVE B
1
Cleared 510(K)
K
91
1948
MEDI GUARD PILLOWCASE
1
Cleared 510(K)
K
91
1953
MEDI GUARD SHEETS/UNDERLAYS
1
Cleared 510(K)
K
91
1952
MEDI GUARD UNDERPAD
1
Cleared 510(K)
K
91
1950
MEDI GUARD DRAPES
1
Cleared 510(K)
K
90
5003
BIO-GUARD SHAVE PREP TRAY
1
Cleared 510(K)
K
90
4274
RECEIVING BLANKET
1
Cleared 510(K)
K
90
1509
TRAUMA SLEEVE
1
Cleared 510(K)
K
90
1629
CHEM-SLEEVE
1
Cleared 510(K)
K
90
0643
FLUID SOAKERSHIELD
1
Cleared 510(K)
K
89
6043
MATTRESS COVER FOR MEDICAL PURPOSES
1
Cleared 510(K)
K
89
1986
MULTIPLE-VARIOUS TYPES OF ABSORBENT INCONTINENCE
1
Cleared 510(K)
K
89
4170
DEVON DISPOSABLE HEAD POSITIONER COVER
1
Cleared 510(K)
K
88
4380
BED SHEET, PILLOW CASE
1
Cleared 510(K)
K
88
2332
HEADREST, PATIENT COMFORT
1
Cleared 510(K)
K
88
1969
DRY COMFORT DISPOSABLE UNDERPAD
1
Cleared 510(K)
K
88
1859
DRIPRIDE DISPOSABLE UNDERPAD
1
Cleared 510(K)
K
87
1725
DRIPRIDE DISPOSABLE UNDERPADS
1
Cleared 510(K)
K
87
0925
PAD, BED LINEN PROTECTIVE
1
Cleared 510(K)
K
87
0522
DEPEND UNDERPAD
1
Cleared 510(K)
K
86
4158
THERMAPAD
1
Cleared 510(K)
K
86
3179
KIMLON DISPOSABLE BLANKET
1
Cleared 510(K)
K
86
2348
SINGLE-USE PATIENT UNDERPAD
1
Cleared 510(K)
K
86
0066
REFLECTIVE BLANKET
1
Cleared 510(K)
K
85
3970
ALPHA CHUCK
1
Cleared 510(K)
K
85
3880
ATTENDS DISPOS. UNDERPAD
1
Cleared 510(K)
K
85
0067
MEDICAL, DISPOSABLE BEDDING
1
Cleared 510(K)
K
85
0811
PAD, PRE-OPERATIVE PREPARATION
1
Cleared 510(K)
K
85
0544
SHAVE PREP TRAY
1
Cleared 510(K)
K
84
4196
WET SKIN SCRUB TRAY STERILE WET SKIN SCRUB KIT
1
Cleared 510(K)
K
84
2989
SHAVE PREP KITS
1
Cleared 510(K)
K
84
3038
DISPOSABLE PATIENT BLANKET
1
Cleared 510(K)
K
84
3402
MOLINEA UNDERPADS
1
Cleared 510(K)
K
84
2335
PILLOW W/STAPHCHEK TICKING
1
Cleared 510(K)
K
84
2336
DISPOSABLE PILLOW
1
Cleared 510(K)
K
83
2487
DRAW SHEET, ANTI-MICROBIAL
1
Cleared 510(K)
K
83
2486
PILLOW COVER, ANTI-MICROBIAL
1
Cleared 510(K)
K
82
2650
SUPER DONUT
1
Cleared 510(K)
K
82
1835
BARRIER BURN SHEET
1
Cleared 510(K)
K
82
0582
3M THINSULATE DISPOSABLE HOSPITAL BED
1
Cleared 510(K)
K
81
3519
NON-ABSORBENT TOWELS
1
Cleared 510(K)
K
81
3263
PATIENT UNDERPAD
1
Cleared 510(K)
K
81
2079
DISPOSABLE PILLOW
1
Cleared 510(K)
K
81
1232
DISPOSABLE UNDERPADS
1
Cleared 510(K)
K
81
0264
DISPOSABLE PILLOW
1
Cleared 510(K)
K
80
2998
PATIENT CARE DISPOSABLE INFANT SHIRTS
1
Cleared 510(K)
K
80
2730
FLUFF UNDERPAD TYPE UP1002
1
Cleared 510(K)
K
80
2740
FLUFF UNDERPAD TYPE UP1001
1
Cleared 510(K)
K
79
2626
STERILIZATION PROCESS/BABY BLANKET
1
Cleared 510(K)
K
79
0411
AUTO TRAUMA KIT
1
Cleared 510(K)
K
79
0659
INFANT SCALE DISPOSABLE LINER
1
Cleared 510(K)
K
79
0283
PILLOW, CARTER ARM ELEVATION
1
Cleared 510(K)
K
78
2001
ROSEALAE
1
Cleared 510(K)
K
78
1796
BEDDING, DISPOSABLE HOSPITAL
1
Cleared 510(K)
K
78
1354
PILLOWS- SINGLE PATIENT USE
1
Cleared 510(K)
K
78
1227
TOWELS, SHEETS, PILLOWCASES
1
Cleared 510(K)
K
77
0486
SHEET KIT, STRETCHER, DISPOSABLE
1
Cleared 510(K)
K
76
1108
PLASTIC DISPOSABLE BIB
1
Cleared 510(K)
K
76
1109
TERRYCLOTH BIBS
1
Cleared 510(K)
KMG
Purifier, Water, Ultraviolet, Medical
2
Product Code
KMH
Sterilizer, Dry Heat
2
Product Code
KMJ
Lubricant, Patient
1
Product Code
KMN
Chair And Table, Medical
1
Product Code
KXF
Applicator, Absorbent Tipped, Non-Sterile
1
Product Code
KXG
Applicator, Absorbent Tipped, Sterile
1
Product Code
KYR
Bag, Ice
1
Product Code
KYS
Insoles, Medical
1
Product Code
KYT
Light, Examination, Medical, Battery Powered
1
Product Code
KYW
Container, Liquid Medication, Graduated
1
Product Code
KYX
Dispenser, Liquid Medication
1
Product Code
KYZ
Syringe, Irrigating (Non Dental)
1
Product Code
KZA
Device, Vein Location, Liquid Crystal
1
Product Code
KZF
Device, Medical Examination, Ac Powered
1
Product Code
KZH
Introducer, Syringe Needle
2
Product Code
LBJ
Device, Vein Stabilization
1
Product Code
LDS
Device, Pasteurization, Hot Water
2
Product Code
LRJ
Disinfectant, Medical Devices
1
Product Code
LYY
Latex Patient Examination Glove
1
Product Code
LYZ
Vinyl Patient Examination Glove
1
Product Code
LZA
Polymer Patient Examination Glove
1
Product Code
LZB
Finger Cot
1
Product Code
LZC
Patient Examination Glove, Specialty
1
Product Code
MDZ
Cleaners, Medical Devices
2
Product Code
MEC
Disinfector, Medical Devices
2
Product Code
MED
Sterilant, Medical Devices
2
Product Code
MKB
Device, Germicidal, Ultraviolet
2
Product Code
MLR
Sterilizer, Chemical
2
Product Code
MMS
Lubricant, Vaginal, Patient
1
Product Code
MTV
Sharps Needle Destruction Device
2
Product Code
NRV
Implantable Radio Frequency Transponder System
2
Product Code
NZD
Stretcher, Patient Restraint
1
Product Code
NZH
Medication Management System, Remote
2
Product Code
NZJ
Respirator, N95, For Use By The General Public In Public Health Medical Emergencies
2
Product Code
OHY
Pill Crusher/Cutter
1
Product Code
OIG
Powder-Free Guayle Rubber Examination Glove
1
Product Code
PEQ
Accessories To Examination Light
1
Product Code
OPC
Powder-Free Polychloroprene Patient Examination Glove
1
Product Code
OPH
Radiation Attenuating Medical Glove
1
Product Code
OPI
Antimicrobial Medical Glove
1
Product Code
OPJ
Medical Gloves With Chemotherapy Labeling Claims - Test For Use With Chemotherapy Drugs
1
Product Code
ORW
N95 Respirator With Antimicrobial/Antiviral Agent For Use By The General Public In Public Health Medical Emergencies
2
Product Code
OSZ
Antimicrobial Keyboard
2
Product Code
OUG
Medical Device Data System
1
Product Code
OVY
Liquid Chemical Processing System
2
Product Code
OYS
Patient Bed With Canopy/Restraints
1
Product Code
PAD
Chest Drainage Kit
2
Product Code
PEC
Sterilizer Automated Loading System
2
Product Code
PJJ
Two Or More Sterilant Sterilizer
2
Product Code
PWM
Admission Kit (Patient Utensil)
1
Product Code
PYQ
Rfid Chip For Dental Appliance
2
Product Code
PWP
Blood Borne Pathogen Response Kit
1
Product Code
PWS
Chemotherapy Administration Kit
1
Product Code
PWT
Chemotherapy Spill Clean-Up Kit
1
Product Code
PWU
Clean-Up Kit
1
Product Code
PWV
Delivery Room Apparel Kit
1
Product Code
PWZ
Mid-Stream Collection Kit
1
Product Code
PXA
Oral Administration Set
1
Product Code
PXC
Personal Protection Kit
1
Product Code
PXD
Prep Kit
1
Product Code
PXF
Sitz Bath Kit
1
Product Code
PXG
Spill Kit
1
Product Code
PXM
Vomitus Clean-Up Kit
1
Product Code
QDO
Fentanyl And Other Opioid Protection Glove
1
Product Code
QTV
Mattress And Bed Deck Cover (Medical Purposes)
1
Product Code
Subpart G—Miscellaneous Devices
CFR Sub-Part
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
HO
/
subpart-g—general-hospital-and-personal-use-miscellaneous-devices
/
KME
/
K871725
View Source
DRIPRIDE DISPOSABLE UNDERPADS
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K871725
510(k) Type
Traditional
Applicant
WEYERHAEUSER CO.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
5/15/1987
Days to Decision
11 days
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
Subpart B—Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart C—General Hospital and Personal Use Monitoring Devices
Subpart D—Pathology Instrumentation and Accessories
Subpart D—Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—General Hospital and Personal Use Therapeutic Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
Subpart F—Therapeutic Devices
Subpart G—General Hospital and Personal Use Miscellaneous Devices
FLG
Cleaner, Ultrasonic, Medical Instrument
FLH
Washer Of Body Waste Receptacles
FLI
Cabinet, Ethylene-Oxide Gas Aerator
BRT
Restraint, Patient, Conductive
BYY
Tube, Aspirating, Flexible, Connecting
BYZ
Trap, Sterile Specimen
CBC
Bottle, Collection And Trap, Breathing System (Uncalibrated)
CBD
Bottle, Collection, Breathing System (Calibrated)
FLE
Sterilizer, Steam
FLF
Sterilizer, Ethylene-Oxide Gas
FMA
Depressor, Tongue, Non-Surgical
FMC
Patient Examination Glove
FME
Gown, Examination
FML
Chair, Blood Donor
FMP
Protector, Skin Pressure
FMQ
Restraint, Protective
FMR
Device, Transfer, Patient, Manual
FMW
Cover, Mattress (Medical Purposes)
FNP
Urinal
FNS
Ring Cutter
FNY
Basin, Emesis
FOA
Board, Cardiopulmonary
FOB
Bedpan
FOX
Stand, Infusion
FPF
Bottle, Hot/Cold Water
FPO
Stretcher, Wheeled
FPP
Stretcher, Hand-Carried
FPS
Board, Bed
FRA
Purifier, Air, Ultraviolet, Medical
FRG
Wrap, Sterilization
FRJ
Chair, Geriatric
FRK
Chair, Examination And Treatment
FRZ
Device, Patient Transfer, Powered
GAZ
Tubing, Noninvasive
GCX
Apparatus, Suction, Operating-Room, Wall Vacuum Powered
JOK
Scissors, Medical, Disposable
JOL
Catheter And Tip, Suction
KCT
Sterilization Wrap Containers, Trays, Cassettes & Other Accessories
KDP
Regulator, Vacuum
KDQ
Bottle, Collection, Vacuum
KIA
Cover, Cast
KME
Bedding, Disposable, Medical
K
04
2145
READY-HEAT BLANKET
K
94
4953
OREX MEDICAL BEDDING
K
93
3636
DISPOSE-A-SHEET
K
93
2539
DOCTOR DOWN --RESCUE WRAP
K
92
2143
AMERICAN BURN SHEET
K
91
5303
FOIL BABY BUNTING
K
91
2257
CHEM-SLEEVE B
K
91
1948
MEDI GUARD PILLOWCASE
K
91
1953
MEDI GUARD SHEETS/UNDERLAYS
K
91
1952
MEDI GUARD UNDERPAD
K
91
1950
MEDI GUARD DRAPES
K
90
5003
BIO-GUARD SHAVE PREP TRAY
K
90
4274
RECEIVING BLANKET
K
90
1509
TRAUMA SLEEVE
K
90
1629
CHEM-SLEEVE
K
90
0643
FLUID SOAKERSHIELD
K
89
6043
MATTRESS COVER FOR MEDICAL PURPOSES
K
89
1986
MULTIPLE-VARIOUS TYPES OF ABSORBENT INCONTINENCE
K
89
4170
DEVON DISPOSABLE HEAD POSITIONER COVER
K
88
4380
BED SHEET, PILLOW CASE
K
88
2332
HEADREST, PATIENT COMFORT
K
88
1969
DRY COMFORT DISPOSABLE UNDERPAD
K
88
1859
DRIPRIDE DISPOSABLE UNDERPAD
K
87
1725
DRIPRIDE DISPOSABLE UNDERPADS
K
87
0925
PAD, BED LINEN PROTECTIVE
K
87
0522
DEPEND UNDERPAD
K
86
4158
THERMAPAD
K
86
3179
KIMLON DISPOSABLE BLANKET
K
86
2348
SINGLE-USE PATIENT UNDERPAD
K
86
0066
REFLECTIVE BLANKET
K
85
3970
ALPHA CHUCK
K
85
3880
ATTENDS DISPOS. UNDERPAD
K
85
0067
MEDICAL, DISPOSABLE BEDDING
K
85
0811
PAD, PRE-OPERATIVE PREPARATION
K
85
0544
SHAVE PREP TRAY
K
84
4196
WET SKIN SCRUB TRAY STERILE WET SKIN SCRUB KIT
K
84
2989
SHAVE PREP KITS
K
84
3038
DISPOSABLE PATIENT BLANKET
K
84
3402
MOLINEA UNDERPADS
K
84
2335
PILLOW W/STAPHCHEK TICKING
K
84
2336
DISPOSABLE PILLOW
K
83
2487
DRAW SHEET, ANTI-MICROBIAL
K
83
2486
PILLOW COVER, ANTI-MICROBIAL
K
82
2650
SUPER DONUT
K
82
1835
BARRIER BURN SHEET
K
82
0582
3M THINSULATE DISPOSABLE HOSPITAL BED
K
81
3519
NON-ABSORBENT TOWELS
K
81
3263
PATIENT UNDERPAD
K
81
2079
DISPOSABLE PILLOW
K
81
1232
DISPOSABLE UNDERPADS
K
81
0264
DISPOSABLE PILLOW
K
80
2998
PATIENT CARE DISPOSABLE INFANT SHIRTS
K
80
2730
FLUFF UNDERPAD TYPE UP1002
K
80
2740
FLUFF UNDERPAD TYPE UP1001
K
79
2626
STERILIZATION PROCESS/BABY BLANKET
K
79
0411
AUTO TRAUMA KIT
K
79
0659
INFANT SCALE DISPOSABLE LINER
K
79
0283
PILLOW, CARTER ARM ELEVATION
K
78
2001
ROSEALAE
K
78
1796
BEDDING, DISPOSABLE HOSPITAL
K
78
1354
PILLOWS- SINGLE PATIENT USE
K
78
1227
TOWELS, SHEETS, PILLOWCASES
K
77
0486
SHEET KIT, STRETCHER, DISPOSABLE
K
76
1108
PLASTIC DISPOSABLE BIB
K
76
1109
TERRYCLOTH BIBS
KMG
Purifier, Water, Ultraviolet, Medical
KMH
Sterilizer, Dry Heat
KMJ
Lubricant, Patient
KMN
Chair And Table, Medical
KXF
Applicator, Absorbent Tipped, Non-Sterile
KXG
Applicator, Absorbent Tipped, Sterile
KYR
Bag, Ice
KYS
Insoles, Medical
KYT
Light, Examination, Medical, Battery Powered
KYW
Container, Liquid Medication, Graduated
KYX
Dispenser, Liquid Medication
KYZ
Syringe, Irrigating (Non Dental)
KZA
Device, Vein Location, Liquid Crystal
KZF
Device, Medical Examination, Ac Powered
KZH
Introducer, Syringe Needle
LBJ
Device, Vein Stabilization
LDS
Device, Pasteurization, Hot Water
LRJ
Disinfectant, Medical Devices
LYY
Latex Patient Examination Glove
LYZ
Vinyl Patient Examination Glove
LZA
Polymer Patient Examination Glove
LZB
Finger Cot
LZC
Patient Examination Glove, Specialty
MDZ
Cleaners, Medical Devices
MEC
Disinfector, Medical Devices
MED
Sterilant, Medical Devices
MKB
Device, Germicidal, Ultraviolet
MLR
Sterilizer, Chemical
MMS
Lubricant, Vaginal, Patient
MTV
Sharps Needle Destruction Device
NRV
Implantable Radio Frequency Transponder System
NZD
Stretcher, Patient Restraint
NZH
Medication Management System, Remote
NZJ
Respirator, N95, For Use By The General Public In Public Health Medical Emergencies
OHY
Pill Crusher/Cutter
OIG
Powder-Free Guayle Rubber Examination Glove
PEQ
Accessories To Examination Light
OPC
Powder-Free Polychloroprene Patient Examination Glove
OPH
Radiation Attenuating Medical Glove
OPI
Antimicrobial Medical Glove
OPJ
Medical Gloves With Chemotherapy Labeling Claims - Test For Use With Chemotherapy Drugs
ORW
N95 Respirator With Antimicrobial/Antiviral Agent For Use By The General Public In Public Health Medical Emergencies
OSZ
Antimicrobial Keyboard
OUG
Medical Device Data System
OVY
Liquid Chemical Processing System
OYS
Patient Bed With Canopy/Restraints
PAD
Chest Drainage Kit
PEC
Sterilizer Automated Loading System
PJJ
Two Or More Sterilant Sterilizer
PWM
Admission Kit (Patient Utensil)
PYQ
Rfid Chip For Dental Appliance
PWP
Blood Borne Pathogen Response Kit
PWS
Chemotherapy Administration Kit
PWT
Chemotherapy Spill Clean-Up Kit
PWU
Clean-Up Kit
PWV
Delivery Room Apparel Kit
PWZ
Mid-Stream Collection Kit
PXA
Oral Administration Set
PXC
Personal Protection Kit
PXD
Prep Kit
PXF
Sitz Bath Kit
PXG
Spill Kit
PXM
Vomitus Clean-Up Kit
QDO
Fentanyl And Other Opioid Protection Glove
QTV
Mattress And Bed Deck Cover (Medical Purposes)
Subpart G—Miscellaneous Devices
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
HO
/
subpart-g—general-hospital-and-personal-use-miscellaneous-devices
/
KME
/
K871725
View Source
DRIPRIDE DISPOSABLE UNDERPADS
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K871725
510(k) Type
Traditional
Applicant
WEYERHAEUSER CO.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
5/15/1987
Days to Decision
11 days