INTRAVIA CONTAINER, EMPTY

K964853 · Baxter Healthcare Corp · KPE · Mar 31, 1997 · General Hospital

Device Facts

Record IDK964853
Device NameINTRAVIA CONTAINER, EMPTY
ApplicantBaxter Healthcare Corp
Product CodeKPE · General Hospital
Decision DateMar 31, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.5025
Device ClassClass 2

Indications for Use

Baxter is currently marketing a line of empty Viaflex® plastic containers used for the preparation and administration of drug admixtures. We propose to change the materials of the container sheeting, administration and medication ports and medication site and market the container under the tradename IntraVia™ Container, Empty.

Device Story

IntraVia™ Empty Plastic Container; used for preparation/administration of drug admixtures. Replaces Viaflex® container; utilizes new material composition for container sheeting, administration/medication ports, and medication site. Enables transition from ETO to gamma sterilization. Benefits include thermoplastic recyclability, reduced environmental contaminants (HCl, dioxins) during incineration, and elimination of natural rubber proteins in medication site to prevent sensitivity reactions. Used in clinical settings by healthcare providers for IV therapy preparation.

Clinical Evidence

Bench testing only. Evaluated biological/chemical reactivity per ISO 10993-1 and USP Physicochemical standards. Functional performance testing included residual volume, fill volume, spike insertion/removal force, and burst testing. Drug compatibility studies performed with commonly admixed drugs under representative storage conditions.

Technological Characteristics

Empty IV container; materials modified from predicate. Sterilization: Gamma radiation. Functional specs: residual volume, fill volume, spike insertion/removal force, burst testing. Compliant with ISO 10993-1 and USP Physicochemical standards.

Indications for Use

Indicated for the preparation and administration of drug admixtures in clinical settings.

Regulatory Classification

Identification

An I.V. container is a container made of plastic or glass used to hold a fluid mixture to be administered to a patient through an intravascular administration set.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} 510(k) Premarket Notification IntraVia™ Empty Plastic Container 510(k) SUMMARY R 964853 ## Submitted by: Mary Ellen Snyder MA 31 1997 Baxter Healthcare Corporation I.V. Systems Division Rte. 120 and Wilson Road Round Lake, IL 60073 **Date Prepared:** November 26, 1996 **Proposed Device:** IntraVia™ Empty Plastic Container **Predicate Devices:** Viaflex® Empty Plastic Container **Proposed Device Description:** Baxter is currently marketing a line of empty Viaflex® plastic containers used for the preparation and administration of drug admixtures. We propose to change the materials of the container sheeting, administration and medication ports and medication site and market the container under the tradename IntraVia™ Container, Empty. The primary reason for the change in container materials is to allow a change in sterilization methods from ETO to gamma sterilization. In addition, use of the IntraVia™ container in place of the Viaflex® container offers several benefits including use of standard thermoplastic methods for recycling and reduction in the amounts of environmental contaminants released during incineration of PVC such as hydrochloric acid and dioxins. The material change in the medication site is being made to improve user safety by eliminating the potential for sensitivity reactions associated with natural rubber proteins. ## Summary of Technological Characteristics of New Device to Predicate Devices The proposed IntraVia™ container is the same in overall design and intended use as the currently marketed Viaflex® container. The IntraVia™ container differs from the Viaflex® container in material composition and sterilization method. s:\510k\intrasum NOV 26 1996 95 {1} 510(k) Premarket Notification IntraVia™ Empty Plastic Container # Discussion of Nonclinical Tests; Conclusions Drawn from Nonclinical Tests The biological and chemical reactivity of the new container materials have been assessed using biological methods specified in ISO Standard 10993-1 and USP Physicochemical tests. The materials were found to be acceptable for their intended use. Data regarding the functional performance of the proposed empty IV container and its drug compatibility characteristics have been generated. Functional performance studies included residual volume, fill volume, spike insertion/removal force and burst testing. Performance testing indicate that the proposed container meets or exceeds all functional requirements and support its suitability for use. Drug compatibility studies were conducted with commonly admixed drugs or those that have a high potential to adsorb to the container under representative storage conditions. Results of drug compatibility evaluations support the suitability of the new container for its intended use. s:\510k\intrason NOV 26 1996 96
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...