K960826 · Sims Deltec, Inc. · FRN · Aug 23, 1996 · General Hospital
Device Facts
Record ID
K960826
Device Name
CADD-PRIZM MODEL 6100 PUMP
Applicant
Sims Deltec, Inc.
Product Code
FRN · General Hospital
Decision Date
Aug 23, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5725
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Model 6100 pump provides measured drug therapy for intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural space or subarachnoid space delivery to patients in hospital or outpatient settings.
Device Story
Ambulatory infusion pump; delivers measured drug therapy via intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural, or subarachnoid routes. Used in hospital or outpatient settings. Stores 1-4 delivery applications (TPN, continuous, intermittent). Operated by clinicians or patients. Provides controlled drug delivery; mitigates risks of over/under-infusion common to ambulatory pumps.
Clinical Evidence
No clinical studies performed. Evidence based on functional testing, software validation, and verification of software-controlled programming functions.
Technological Characteristics
Ambulatory infusion pump; software-controlled programming for TPN, continuous, and intermittent delivery. Supports multiple delivery routes. No specific materials or connectivity standards provided.
Indications for Use
Indicated for patients requiring measured drug therapy via intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural, or subarachnoid routes in hospital or outpatient settings.
Regulatory Classification
Identification
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
Predicate Devices
Abbott Laboratories AIM™ System
Deltec's CADD-Prizm™ Model 6100 PCS (Pain Control System)
Related Devices
K982836 — CADD-LEGACY PLUS AMBULATORY INFUSION SYSTEM · Sims Deltec, Inc. · Nov 2, 1998
K982839 — CADD-LEGACY PCA AMBULATORY INFUSION SYSTEM, MODEL 6300 · Sims Deltec, Inc. · Nov 2, 1998
K955180 — CADD-PCA, -MICRO, -PRIZM AMBULATORY INFUSION PUMP · Sims Deltec, Inc. · May 23, 1996
K990259 — DISETRONIC MULTIFUSE INFUSION PUMP SYSTEM · Disetronic Medical Systems · Feb 12, 1999
K141389 — SAPPHIRE INFUSION PUMP · Q Core Medical , Ltd. · Dec 11, 2014
Submission Summary (Full Text)
{0}
K960826
AUG 23 1988
510(k) SUMMARY OF SAFETY AND EFFECTIVENESS
for the
CADD-Prizm™ MODEL 6100 AMBULATORY INFUSION SYSTEM
## I. GENERAL INFORMATION
Common/Usual Name: Ambulatory Infusion Pump
Proprietary Name: CADD-Prizm™ Model 6100 Ambulatory Infusion System
Applicant's name and address: SIMS Deltec, Inc.
1265 Grey Fox Road
St. Paul, MN 55112
Equivalence device comparison: Abbott Laboratories AIM™ System and Deltec's CADD-Prizm™ Model 6100 PCS (Pain Control System).
## II. DEVICE DESCRIPTION
The CADD-Prizm™ Model 6100 ambulatory infusion pump is similar in design, function, and intended use to Abbott Laboratories AIM™ System and Deltec's CADD-Prizm™ Model 6100 PCS (Pain Control System). The Model 6100 pump provides measured drug therapy for intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural space or subarachnoid space delivery to patients in hospital or outpatient settings. The pump is capable of storing one to four delivery applications at one time. The delivery applications supplied for use with the Model 6100 pump and the subject of this 510(k) Notification are the TPN delivery application, continuous delivery application and the intermittent delivery application.
## III. ALTERNATIVES
Alternatives to the CADD-Prizm™ Model 6100 pump include the use of other commercially available ambulatory drug infusion pumps such as Abbott AIM™ System.
Page 1 of 2
{1}
Page 2 of 2
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS
for the
CADD-Prizm™ MODEL 6100 AMBULATORY INFUSION SYSTEM
## V. POTENTIAL ADVERSE EFFECTS
The potential direct adverse effects that may occur when using the CADD-Prizm™ Model 6100 pump, as well as other commercially available non-implantable ambulatory infusion pumps, include the possibility of over-infusion, under-infusion, or no infusion.
## VI. SUMMARY OF STUDIES
### A. Functional Testing
Test plans associated with software validation, verification of software controlled programming functions, and software related to proper pump operation were certified for the CADD-Prizm™ Model 6100 Ambulatory Infusion System.
### B. Clinical Studies
Clinical studies were not deemed necessary regarding the use of the CADD-Prizm™ Model 6100 Ambulatory Infusion System.
## VII. CONCLUSIONS DRAWN FROM THESE STUDIES
Based upon the information provided above, the CADD-Prizm™ Model 6100 Ambulatory Infusion Pump is substantially equivalent to other commercially available ambulatory infusion systems.
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.