STRATO/INFUSAID PERIPORT INFUSION SET 41770,41771
Device Facts
| Record ID | K960391 |
|---|---|
| Device Name | STRATO/INFUSAID PERIPORT INFUSION SET 41770,41771 |
| Applicant | Strato/Infusaid, Inc. |
| Product Code | FPA · General Hospital |
| Decision Date | Jul 3, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 880.5440 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Strato/Infusaid PeriPort Infusion Set is indicated for the infusion of drugs and fluids into the Strato/Infusaid PeriPort Peripheral Access Device.
Device Story
Device provides straight needle access to Strato/Infusaid PeriPort System for infusion of drugs/fluids into vascular access system. Used in clinical settings by healthcare professionals. Device facilitates delivery of therapeutic agents to patient via implanted peripheral access port.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Infusion set for vascular access; features straight needle and specific wing design. Mechanical device; no energy source or software.
Indications for Use
Indicated for patients requiring infusion of drugs and fluids into the Strato/Infusaid PeriPort Peripheral Access Device.
Regulatory Classification
Identification
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
Special Controls
*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.
Predicate Devices
- Strato/Infusaid LifePort Infusion Set (Model No. LPS 3004, LPS 3005, LPS 3006, LPS 3007, LPS 3008, LPS 3009, LPS 3017, LPS 3023, LPS 3025)
- Strato/Infusaid Infuse-a-Port Winged Infusion Set (Model Nos. 41129-1, 41129-2, 41129-3, 41129-4, 41129-5)
Related Devices
- K962230 — CELSITE PORT WITH PRECONNECTED CATHETER · B.Braun Medical, Inc. · Dec 16, 1996
- K972712 — CORE RESISTANT HUBER INFUSION SETS · Icu Medical, Inc. · Oct 1, 1997
- K061424 — CELSITE/ CELSITE CONCEPT, ACCESS PORTS · Aesculap, Inc. · Jul 31, 2006
- K980994 — IV ADMINISTRATION SETS WITH NEEDLE ACCESS DEVICES · Venetec Intl., Inc. · May 29, 1998
- K974829 — NON-PVC FLUID PATH PORT ACCESS INFUSION SET (WITH AND WITHOUT INJECTION SET) · Kawasumi Laboratories Co., Ltd. · Feb 12, 1998