K163659 · I.C Medical, Inc. · FYD · Oct 30, 2017 · General, Plastic Surgery
Device Facts
Record ID
K163659
Device Name
Crystal Vision
Applicant
I.C Medical, Inc.
Product Code
FYD · General, Plastic Surgery
Decision Date
Oct 30, 2017
Decision
SESE
Submission Type
Special
Regulation
21 CFR 878.5070
Device Class
Class 2
Indications for Use
The Crystal Vision Smoke Evacuator System with Accessories is intended to remove smoke created in surgical procedures.
Device Story
Crystal Vision Smoke Evacuator System removes surgical smoke and maintains pneumoperitoneum pressure during laparoscopic procedures; utilizes sensors to detect activation of smoke-producing surgical devices (lasers, electrosurgical units, etc.) for automatic operation; evacuates up to 20 liters-per-minute; includes ULPA filter/water trap and charcoal output filter for odor/particulate removal; operated by trained professionals in surgical settings; features foot pedal for manual activation; system automatically activates upon sensor detection or high-pressure pneumoperitoneum limit; provides smoke/vapor/gas evacuation to improve visibility and safety for surgical staff.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Air-handling apparatus; includes ULPA filter media and granular activated charcoal from coconut shell; chassis dimensions modified for filter enclosure; digital 3-digit flow display; push-button controls; sensor-based automatic activation; compatible with sterile/non-sterile tubing and wands; conforms to ANSI/AAMI/ES 60601-1 and IEC 60601-1-2.
Indications for Use
Indicated for removal of surgical smoke produced by lasers, electrosurgical devices, argon beam coagulators, LEEP devices, and other smoke-producing surgical equipment; includes evacuation of CO2 gas from pneumoperitoneum during laparoscopic procedures.
Regulatory Classification
Identification
Air-handling apparatus for a surgical operating room is a device intended to produce a directed, nonturbulent flow of air that has been filtered to remove particulate matter and microorganisms to provide an area free of contaminants to reduce the possibility of infection in the patient.
Special Controls
*Classification.* Class II (special controls). The device, when it is an air handling bench apparatus, an air handling room apparatus, or an air handling enclosure apparatus, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 878.9.
Predicate Devices
Crystal Vision (Model 470) and Accessories (K932230)
Related Devices
K052797 — LAPEVAC, FILTRATION DEVICE FOR THE PERIOTONEUM · Medtek Devices, Inc. · Feb 13, 2006
K182224 — SafeAir Smoke Evacuator compact · Lina Medical Aps · Feb 7, 2019
K131402 — VISICLEAR SMOKE EVACUATION SYSTEM · Buffalo Filter Co., Inc. · Mar 3, 2014
K200250 — Megadyne Smoke Evacuator, Megadyne Filter, Megadyne Fluid Trap, Megadyne Connect Cable, 1 m and 2.1 m, Megadyne RF Sensor · Megadyne Medical Products, Inc. · Jun 26, 2020
K142335 — RapidVac Smoke Evacuator System · Covidien · Jan 14, 2015
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles a stylized human figure or a caduceus, often associated with healthcare.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
October 30, 2017
I.C Medical, Inc. Elena S. Buiga Director Of RA/QA/ISO 2340 W. Shangri La Rd. Phoenix, Arizona 85029
Re: K163659 Trade/Device Name: Crystal Vision Regulation Number: 21 CFR 878.5070 Regulation Name: Air-Handling Apparatus For A Surgical Operating Room Regulatory Class: Class II Product Code: FYD Dated: September 26, 2017 Received: October 3, 2017
Dear Elena S. Buiga:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in
{1}------------------------------------------------
the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely.
# Michael J. Ryan -S
for Tina Kiang, Ph.D. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known)
Device Name
Crystal Vision Smoke Evacuator System with Accessories
Indications for Use (Describe)
The Crystal Vision Smoke Evacuator System with Accessories is intended to remove smoke created in surgical procedures.
Type of Use (Select one or both, as applicable)|X Prescription Use (Part 21 CFR 801 Subpart D)
| | Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
## 510(k) Summary
## Submitter/Holder:
I.C. Medical, Inc. 2340 West Shangri La Road Phoenix, AZ 85029 Phone: (623)-780-0700 Fax: (623)-780-0887
| Contact Person: | Elena Simona Buiga |
|-----------------|------------------------------------------------------------------|
| | Director of RA/QA/ISO |
| | <a href="mailto:simonab@icmedical.com">simonab@icmedical.com</a> |
Date Prepared: October 23, 2017
## Device:
| Device Name: | Crystal Vision Smoke Evacuator System with Accessories |
|----------------------------|--------------------------------------------------------|
| Trade Name: | Crystal Vision |
| Common Name: | Smoke Evacuator System with Accessories |
| Classification Regulation: | 21CFR878.5070 |
| Classification Name: | Apparatus, Exhaust, Surgical |
| Regulation Description: | Air-handling apparatus for surgical operating room. |
| Device class: | 2 |
| Product code: | FYD |
## Predicate Device:
Crystal Vision (Model 470) and Accessories K932230
## Device Description:
The Crystal Vision Smoke Evacuator System with Accessories is designed to remove smoke created in surgical procedures. The Crystal Vision Smoke Evacuator System with Accessories can be used to remove smoke produced by lasers, electrosurgical devices, argon beam coagulators, LEEP devices, and other devices that create smoke during surgical procedures.
During internal surgical procedures such as laparoscopy. it helps to maintain the desired internal pressure (pneumoperitoneum). The Crystal Vision Smoke Evacuator System with Accessories removes up to 20 litersper-minute of smoke produced.
The Crystal Vision Smoke Evacuator System with Accessories automatically activates when active (smoke producing) devices that are coupled to the smoke evacuator, with special sensors, are turned on.
The Crystal Vision Smoke Evacuator System with Accessories automatically turns off, at a time predetermined by the operator, after the active device turns off and automatically activates when the high pressure limit is exceeded in the pneumoperitoneum and it remains running to remove smoke, vapors, and gases until the internal pressure returns to levels below the preset maximum.
The Crystal Vision Smoke Evacuator System with Accessories can be used to evacuate CO2 gas from the pneumoperitoneum at the end of laparoscopic procedures.
The Crystal Vision Smoke Evacuator System with Accessories is intended to be used by trained professionals.
The subject device (Crystal Vision Smoke Evacuator System with Accessories) operates under same technologies, same mechanism of actions as the predicate (Crystal Vision (Model 470) and Accessories) and will use same accessories as the predicate device.
{4}------------------------------------------------
The modifications are: increase dimension of the product chassis to partially enclose the Input ULPA filter and the Output Charcoal filter; replace mechanical controls with push buttons; eliminate Stand By switch; replace flow set display, from bargraph display to 3 digits display; expand flow reading from 2 to 3 digits.
#### Accessories description:
#### The ULPA Filter & Water Trap:
The ULPA Filter & Water Trap for the Crystal Vision Smoke Evacuator System with Accessories, like the filters for the predicate device, is a replaceable filter that is completely enclosed to protect health care personnel from potential contamination during filter change. The ULPA Filter & Water Trap has a ULPA (Ultra Low Penetration Air) media.
#### Charcoal Output Filter:
The Charcoal Output Filter for the Crystal Vision Smoke Evacuator System with Accessories, like the one for the predicate device, is a replaceable filter that is completely enclosed and installed on the back of the Crystal Vision Smoke Evacuator System. The filter contains Granular Activated Charcoal from coconut shell and its life is based on the ability of the charcoal to absorb odors.
#### Sensor:
The Sensor for the Crystal Vision Smoke Evacuator System with Accessories, like the sensor for the predicate device, is an accessory which activates the Crystal Vision Smoke Evacuator automatically, when a cutting, smoke producing device will activate.
#### Foot Pedal:
The foot pedal is used for end user convenience as to activate the smoke evacuator when needed. The foot pedal shall be connected through same input connector used by sensor(s).
#### Intra-Abdominal Tubing Set, Sterile and Non-Sterile:
The I/A tubing is used during laparoscopic procedures, to evacuate the smoke produced. It connects to the trocar at one end and to the smoke evacuator to the other end.
#### Smoke Tubing, Sterile and Non-Sterile:
The smoke tubing may be used during any surgical procedure where there are smoke producing devices that needs smoke evacuation.
#### Smoke Tubing with In-Line Filter, Non-Sterile:
The smoke tubing may be used during any surgical procedure where there is smoke producing devices that needs smoke evacuation. In addition, the smoke tubing has a HEPA filter
#### Wand, Sterile and Non-Sterile:
The wand is a hand held device that may be used during any surgical procedure where there is smoke producing devices that needs smoke evacuation.
## Indication for Use:
The Crystal Vision Smoke Evacuator System with Accessories is intended to remove smoke created in surgical procedures
## Comparison of Technological Characteristics with the Predicate Device:
This Special 510(k) is a modification to the dimension of the product chassis (partial enclosure of the Input ULPA filter and Output Charcoal filter); replacement of mechanical controls with push buttons; elimination of the Stand By switch; ; replace flow set display, from bargraph display to 3 digits display; expand flow reading from 2 to 3 digits for the previously FDA cleared 510(K) number K932230.
{5}------------------------------------------------
No changes were made to the intended use, indication for use, energy type, performance specifications, materials, sterilization method or fundamental scientific technology.
## Performance Characteristics:
#### Performance Bench Testing:
The Crystal Vision Smoke Evacuator and its Accessories were exposed to performance bench testing to ensure conformance to:
ANSI/AAMI/ES 60601-1-Medical electrical equipment-Part 1: General requirements for basic safety and essential performance;
IEC 60601-1-2-Medical electrical equipment – Part 1-2: General requirements for basic safety and
essential performance - Collateral Standard: Electromagnetic disturbances -Requirements and tests; The Crystal Vision Smoke Evacuator and its Acceptance criteria on all applicable clauses of above mention standards.
#### Clinical testing:
N/A
### Conclusions:
The subject device-Crystal Vision Smoke Evacuator System with Accessories, is substantially equivalent to the predicate device- Crystal Vision (Model 470) and Accessories.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.