BLOOD COLLECTION TUBE HOLDER VANISHPOINT TUBE HOLDER/SMALL TUBE ADAPTER

K971763 · Retractable Technologies, Inc. · FMI · Aug 26, 1997 · General Hospital

Device Facts

Record IDK971763
Device NameBLOOD COLLECTION TUBE HOLDER VANISHPOINT TUBE HOLDER/SMALL TUBE ADAPTER
ApplicantRetractable Technologies, Inc.
Product CodeFMI · General Hospital
Decision DateAug 26, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.5570
Device ClassClass 2

Indications for Use

The function of the VanishPoint® Tube Holder is to provide a safe and reliable method for facilitating blood withdrawal from a patient into evacuated blood collection tubes without exposing the phlebotomist to an accidental needlestick injury. The VanishPoint® Tube Holder works like a conventional tube holder except for its ability to retract the contaminated needle inside of the tube holder immediately after blood collection. Regular size collection tubes are inserted into the tube holder blood through the blood collection needle. Regular size collection tubes are 13mm and 16mm diameter. After the last evacuated tube is removed and the tube holder endcap is pressed onto the back-end of the needle retraction mechanism is automatically activated and the contaminated needle is withdrawn from the patient's vein and carried into the tube holder. The tube holder This automatic needle retraction protects the phlebotomist from an accidental needlestick. cannot be reused. Accidental needlesticks typically occur between removing the needle from the patient, removing the needle from a reusable tube holder and disposing of the needle into a sharps disposal container. The function of the VanishPoint®Small Tube Adapter is to permit the phlebotomist to use the VanishPoint® Tube Holder with small volume blood collection tubes. Small volume collection tubes are 10.25mm in diameter. The tube adapter is inserted into the tube holder and the small collection tube is inserted into the tube adapter. After the evacuated tube is filled with blood, the tube adapter is removed from the tube is removed from the tube adapter. The tube adapter can be reused.

Device Story

Device consists of VanishPoint® Tube Holder and Small Tube Adapter; facilitates blood collection into evacuated tubes. Operates as conventional holder with integrated automatic needle retraction mechanism; activated by pressing endcap after tube removal; retracts contaminated needle into holder body to prevent needlestick injuries. Used by phlebotomists in clinical settings. Tube holder is single-use; adapter is reusable. Benefits include reduced risk of accidental needlestick during needle removal and disposal.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Mechanical blood collection tube holder with integrated spring-loaded needle retraction mechanism. Compatible with 13mm and 16mm evacuated tubes; 10.25mm tubes require reusable adapter. Single-use holder design.

Indications for Use

Indicated for use by phlebotomists to facilitate blood withdrawal from patients into evacuated blood collection tubes (13mm, 16mm, or 10.25mm diameter with adapter) while providing protection against accidental needlestick injuries via automatic needle retraction.

Regulatory Classification

Identification

A hypodermic single lumen needle is a device intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. The device consists of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three heads, representing service to individuals and families. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES · USA" is arranged in a circular fashion around the eagle symbol. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Mr. Terance Grisso Director, Regulatory Affairs & Quality Retractable technologies, Incorporated 511 Lobo Lane P.O. Box 9 75068 Little Elm, Texas AUG 26 1997 K971763 Re : Blood Collection Tube Holder Vanishpoint™ Trade Name: Tube Holder and Vanishpoint™ Small Tube Adapter II Requlatory Class: Product Code: FMI Dated: August 4, 1997 August 5, 1997 Received: Dear Mr. Grisso: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. ﮐﮯ ﻧ substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: {1}------------------------------------------------ Page 2 - Mr. Grisso this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or requlations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4618. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Timothy A. Ulatowski Timot Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radioloqical Health Enclosure {2}------------------------------------------------ K97/763 ## Indications For Use ## 510(K) Number (if known): K971763 VanishPoint® Tube Holder and VanishPoint®Small Tube Adapter Device Name: ## Indications for Use: The function of the VanishPoint® Tube Holder is to provide a safe and reliable method for facilitating blood withdrawal from a patient into evacuated blood collection tubes without exposing the phlebotomist to an accidental needlestick injury. The VanishPoint® Tube Holder works like a conventional tube holder except for its ability to retract the contaminated needle inside of the tube holder immediately after blood collection. Regular size collection tubes are inserted into the tube holder blood through the blood collection needle. Regular size collection tubes are 13mm and 16mm diameter. After the last evacuated tube is removed and the tube holder endcap is pressed onto the back-end of the needle retraction mechanism is automatically activated and the contaminated needle is withdrawn from the patient's vein and carried into the tube holder. The tube holder This automatic needle retraction protects the phlebotomist from an accidental needlestick. cannot be reused. Accidental needlesticks typically occur between removing the needle from the patient, removing the needle from a reusable tube holder and disposing of the needle into a sharps disposal container. The function of the VanishPoint®Small Tube Adapter is to permit the phlebotomist to use the VanishPoint® Tube Holder with small volume blood collection tubes. Small volume collection tubes are 10.25mm in diameter. The tube adapter is inserted into the tube holder and the small collection tube is inserted into the tube adapter. After the evacuated tube is filled with blood, the tube adapter is removed from the tube is removed from the tube adapter. The tube adapter can be reused. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) *Palacia Cucenti* Division of Dental, Infection Control, and General Hospital Devices 510(k) Number *K971763* Prescription Use √ OR Over-The-Counter Use **__** (Optional Format 1-2-96)
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...