BRZ · Set, Blood Transfusion

General Hospital · 21 CFR 880.5440 · Class 2

Overview

Product CodeBRZ
Device NameSet, Blood Transfusion
Regulation21 CFR 880.5440
Device ClassClass 2
Review PanelGeneral Hospital
3rd-Party ReviewableYes

Identification

An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.

Classification Rationale

Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

Special Controls

*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

Recent Cleared Devices (20 of 30)

Showing 20 most recent of 30 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K220558Blood Administration SetsBaxter Healthcare CorporationNov 17, 2022SESE
K210335Blood Administration SetBaxter Healthcare CorporationJun 10, 2021SESE
K132905200 MICRON BLOOD COMPONENT FILTER AND SYRINGE ADAPTERArteriocyte Medical Systems, Inc.Oct 4, 2013SESE
K083349BLOOD TRANSFUSION SETShan Dong Wei Gao Group Medical Polymer ProductsApr 10, 2009SESE
K073339BLOOD COMPONENT RECIPIENT SET WITH STANDARD SIZE FILTER AND INFUSION SET WITH SIDE ARM LUER CONNECTORFenwal, Inc.Mar 3, 2008SESE
K041496PENTATRASFU BLOOD TRANSFUSION SETSPentaferte S.P.AJun 30, 2005SESE
K05080530 ML OR 60 ML PEDI-SYRINGE FILTERBlood Products Specialties, LLCJun 20, 2005SESE
K050115BLOOD HAND PUMP ADMINISTRATION SETCardinal Health, Alaris ProductsApr 1, 2005SESE
K023039BLOOD/SOLUTION ADMINISTRATION SET, MODEL 33.015Tuta Healthcare Pty LimitedNov 7, 2002SESE
K000685CHARTER MEDICAL NEONATAL SYRINGE SETCharter Medical, Ltd.Aug 15, 2000SESE
K993120MODIFIED BLOOD RECIPIENT SETBaxter Healthcare CorpNov 17, 1999SESE
K972843PROTOS BLOOD TRANSFUSION SETGlobe Ent., Inc.Dec 16, 1997SESE
K940074Y-TYPE BLOOD ADMINISTRATION SETPuritas Health Care, Inc.Apr 21, 1994SESE
K940055MULTISETPuritas Health Care, Inc.Apr 15, 1994SESE
K921595Y-TYPE BLOOD ADMINISTRATION SET MODEL #HT-TR2Haemotronic, Inc.Dec 24, 1992SESE
K920788BLOOD ADMINISTRATION SETDouglas Medical Products Corp.Jun 4, 1992SESE
K880174JMS TRANSFUSION SETJms Co., Ltd.Feb 16, 1988SESE
K871908IV ADMINISTRATION SETTravenol Laboratories, S.A.Jul 27, 1987SESE
K864441CHURCHILL BLOOD ADMINISTRATION SETChurchill Corp.Jan 20, 1987SESE
K861523STANDARD BLOOD TRANSFUSION FILTER SET (CODE 1025)Jufrey Multimed Corp.May 27, 1986SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...