FRESENIUS ON LINE CLEARANCE MONITOR WITH THE ADDITION OF ACCESS FLOW DETERMINATION
Device Facts
| Record ID | K991520 |
|---|---|
| Device Name | FRESENIUS ON LINE CLEARANCE MONITOR WITH THE ADDITION OF ACCESS FLOW DETERMINATION |
| Applicant | Fresenius Medical Care North America |
| Product Code | KDI · Gastroenterology, Urology |
| Decision Date | Jul 30, 1999 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.5860 |
| Device Class | Class 2 |
Intended Use
The Fresenius On Line Clearance Monitor is intended to be used as a module with the Fresenius 2008H hemodialysis machine for determination of dialysis treatment urea clearance and for access flow estimation for those patients undergoing acute or chronic hemodialysis.
Device Story
The Fresenius On Line Clearance Monitor functions as an integrated module for the Fresenius 2008H hemodialysis machine. It performs real-time monitoring of dialysis treatment by calculating urea clearance and estimating vascular access flow. The device processes data derived from the hemodialysis circuit to provide clinicians with quantitative metrics regarding treatment efficacy and access patency. Used in clinical settings by healthcare professionals, the output assists in managing dialysis therapy and identifying potential access complications. By providing continuous or periodic assessment of clearance and flow, the device supports optimized dialysis delivery and early detection of access dysfunction, potentially improving patient outcomes during acute or chronic hemodialysis sessions.
Clinical Evidence
No clinical data provided in the document; substantial equivalence determination based on regulatory review of the 510(k) submission.
Technological Characteristics
Module for Fresenius 2008H hemodialysis machine; utilizes integrated sensing for urea clearance and access flow estimation; software-based processing; operates within the hemodialysis circuit environment.
Indications for Use
Indicated for patients undergoing acute or chronic hemodialysis requiring monitoring of dialysis treatment urea clearance and access flow estimation.
Regulatory Classification
Identification
A high permeability hemodialysis system is a device intended for use as an artificial kidney system for the treatment of patients with renal failure, fluid overload, or toxemic conditions by performing such therapies as hemodialysis, hemofiltration, hemoconcentration, and hemodiafiltration. Using a hemodialyzer with a semipermeable membrane that is more permeable to water than the semipermeable membrane of the conventional hemodialysis system (§ 876.5820), the high permeability hemodialysis system removes toxins or excess fluid from the patient's blood using the principles of convection (via a high ultrafiltration rate) and/or diffusion (via a concentration gradient in dialysate). During treatment, blood is circulated from the patient through the hemodialyzer's blood compartment, while the dialysate solution flows countercurrent through the dialysate compartment. In this process, toxins and/or fluid are transferred across the membrane from the blood to the dialysate compartment. The hemodialysis delivery machine controls and monitors the parameters related to this processing, including the rate at which blood and dialysate are pumped through the system, and the rate at which fluid is removed from the patient. The high permeability hemodialysis system consists of the following devices:(1) The hemodialyzer consists of a semipermeable membrane with an in vitro ultrafiltration coefficient (K uf ) greater than 8 milliliters per hour per conventional millimeter of mercury, as measured with bovine or expired human blood, and is used with either an automated ultrafiltration controller or anther method of ultrafiltration control to prevent fluid imbalance.(2) The hemodialysis delivery machine is similar to the extracorporeal blood system and dialysate delivery system of the hemodialysis system and accessories (§ 876.5820), with the addition of an ultrafiltration controller and mechanisms that monitor and/or control such parameters as fluid balance, dialysate composition, and patient treatment parameters (e.g., blood pressure, hematocrit, urea, etc.). (3) The high permeability hemodialysis system accessories include, but are not limited to, tubing lines and various treatment related monitors (e.g., dialysate pH, blood pressure, hematocrit, and blood recirculation monitors).
Special Controls
*Classification.* Class II. The special controls for this device are FDA's:(1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Device—Part I: Evaluation and Testing,’ ” (2) “Guidance for the Content of 510(k)s for Conventional and High Permeability Hemodialyzers,” (3) “Guidance for Industry and CDRH Reviewers on the Content of Premarket Notifications for Hemodialysis Delivery Systems,” (4) “Guidance for the Content of Premarket Notifications for Water Purification Components and Systems for Hemodialysis,” and (5) “Guidance for Hemodialyzer Reuse Labeling.”
Related Devices
- K961465 — 2008H ON LINE CLEARANCE MONITOR · Fresenius USA, Inc. · Jul 3, 1997
- K992227 — CRIT-LINE MONITOR III (CLM III) · In-Line Diagnostics Corp. · Jul 30, 1999
- K011741 — CRIT-LINE MONITOR III TQA (CLM TQA) · Hemametrics · Jul 23, 2002
- K030099 — BAXTER ARENA HEMODIALYSIS DELIVERY SYSTEM, MODEL 1571278000 · Baxter Healthcare Corp · Jun 17, 2003
- K250508 — AK 98 Dialysis Machine (955607) · Vantive US Healthcare, LLC · Aug 1, 2025