FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart B—Obstetrical and Gynecological Diagnostic Devices
CFR Sub-Part
Subpart C—Cardiovascular Monitoring Devices
CFR Sub-Part
Subpart C—Monitoring Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Obstetrical and Gynecological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
EZT
Pacemaker, Bladder
3
Product Code
EZW
Stimulator, Electrical, Implantable, For Incontinence
3
Product Code
EZY
Device, Incontinence, Mechanical/Hydraulic
3
Product Code
FAH
Dilator, Urethral, Mechanical
2
Product Code
BSS
Tube, Nasogastric
2
Product Code
EXA
Selector, Size, Ostomy
1
Product Code
EXB
Collector, Ostomy
1
Product Code
EXD
Irrigator, Ostomy
2
Product Code
EXE
Protector, Ostomy
1
Product Code
EXF
Bag, Bile Collecting
2
Product Code
EXG
Bag, Urine Collecting, Ureterostomy
1
Product Code
EXH
Bag, Urinary, Ileostomy
1
Product Code
EXI
Device, Paste-On For Incontinence, Sterile
1
Product Code
EXJ
Device, Incontinence, Urosheath Type, Sterile
1
Product Code
EXN
Support, Hernia
1
Product Code
EYA
Stylet, Ureteral
1
Product Code
EYB
Catheter, Ureteral, Gastro-Urology
2
Product Code
EYC
Catheter, Upper Urinary Tract
2
Product Code
EYI
Adaptor, Ureteral Catheter
1
Product Code
EYJ
Holder, Ureteral Catheter
1
Product Code
EYK
Connector, Ureteral Catheter
1
Product Code
EYQ
Garment, Protective, For Incontinence
1
Product Code
EYT
Sheath, Corrugated Rubber, For Nonindwelling Catheter, Sterile
1
Product Code
EYZ
System, Urine Drainage, Closed, For Nonindwelling Catheter, Sterile
1
Product Code
EZB
Stylet For Catheter, Gastro-Urology
1
Product Code
EZC
Catheter, Coude
2
Product Code
EZD
Catheter, Straight
2
Product Code
EZK
Catheter, Retention Type
2
Product Code
EZL
Catheter, Retention Type, Balloon
2
Product Code
EZM
Dilator, Esophageal (Metal Olive) Gastro-Urology
2
Product Code
EZN
Dilator, Catheter, Ureteral
2
Product Code
EZQ
Pouch, Colostomy
1
Product Code
EZR
Cement, Stomal Appliance, Ostomy
1
Product Code
EZS
Appliance, Colostomy, Disposable
1
Product Code
FAQ
Bag, Urine Collection, Leg, For External Use, Sterile
1
Product Code
FAT
Bougie, Esophageal, And Gastrointestinal, Gastro-Urology
2
Product Code
FAX
Bougie, Urological
1
Product Code
FBM
Cannula And Trocar, Suprapubic, Non-Disposable
1
Product Code
FBR
Urethrometer
1
Product Code
FBW
Filiform And Filiform Follower
1
Product Code
FBX
Sound, Urethral, Metal Or Plastic
1
Product Code
FCB
Bag, Hemostatic
2
Product Code
FCE
Enema Kit
1
Product Code
FCM
Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)
2
Product Code
FCN
Urinary Drainage Collection Kit, For Indwelling Catheter
2
Product Code
FEF
Tube, Single Lumen, With Mercury Wt Balloon For Intestinal Intubation And / Or Decompression
2
Product Code
FEG
Tube, Double Lumen For Intestinal Decompression And/Or Intubation
2
Product Code
FEW
Catheter, Malecot
2
Product Code
FEX
Instrument, Catheter, Punch
1
Product Code
FEZ
Catheter And Tube, Suprapubic
2
Product Code
FFA
Tube, Drainage, Suprapubic
2
Product Code
FFH
Collector, Urine, Pediatric, For Indwelling Catheter
2
Product Code
FFP
Dilator, Rectal
1
Product Code
FFW
String And Tubes, Gastrointestinal, To Locate Internal Bleeding
2
Product Code
FGD
Catheter, Retention, Barium Enema With Bag
2
Product Code
FGE
Stents, Drains And Dilators For The Biliary Ducts
2
Product Code
FGF
Catheter, Ureteral Disposable (X-Ray)
2
Product Code
FGH
Catheter, Double Lumen Female Urethrographic
2
Product Code
FGI
Catheter, Urethrographic, Male
2
Product Code
FHA
Clamp, Penile
1
Product Code
FHS
Dialyzer, Single Coil
2
Product Code
FHT
Set, Gavage, Infant, Sterile
2
Product Code
FIA
Chair, Dialysis, Unpowered, Without Scales
1
Product Code
FIB
Protector, Transducer, Dialysis
2
Product Code
FID
Tubing, Dialysate
2
Product Code
FIE
Needle, Fistula
2
Product Code
FIF
Set, Dialysis, Single Needle With Uni-Directional Pump
2
Product Code
FIG
Clamp, Tubing, Blood, Automatic
2
Product Code
FIH
Pump, Infusion Or Syringe, Extra-Luminal
2
Product Code
FII
System, Dialysate Delivery, Sealed
2
Product Code
FIJ
System, Dialysate Delivery, Recirculating, Single Pass
2
Product Code
FIK
System, Dialysate Delivery, Recirculating
2
Product Code
FIL
System, Dialysate Delivery, Single Pass
2
Product Code
FIN
Tank, Holding, Dialysis
2
Product Code
FIP
Subsystem, Water Purification
2
Product Code
FIQ
Cannula, A-V Shunt
2
Product Code
FIR
Pump, Blood, Extra-Luminal
2
Product Code
FIS
Flowmeter, Dialysate
2
Product Code
FIW
Alarm, Pillow Pressure
2
Product Code
FIZ
Meter, Conductivity, Non-Remote
2
Product Code
FJA
Manometer, Water
2
Product Code
FJB
Detector, Dialysate Level
2
Product Code
FJC
Detector, Blood Level
2
Product Code
FJD
Detector, Leak, Blood
2
Product Code
FJF
Detector, Air Bubble
2
Product Code
FJG
Dialyzer, Parallel Flow
2
Product Code
FJH
Dialyzer, Disposable
2
Product Code
FJI
Dialyzer, Capillary, Hollow Fiber
2
Product Code
K
19
0459
Hemoflow F3 and F4 Dialyzers
2
Cleared 510(K)
K
12
2952
NIPRO PUREFLUX-L HEMODIALYZER
2
Cleared 510(K)
K
04
3342
POLYFLUX FAMILY HEMODIALYZER/FILTER LABELED FOR SINGLE AND MULTIPLE USE, MODELS 14L, 17L, 21L, 140H, 170H, 210H,6LR, 8LR
2
Cleared 510(K)
K
01
0366
DISPOSABLE STORAGE CAP
2
Cleared 510(K)
K
01
1148
ULTRACONCENTRATOR SYSTEM
2
Cleared 510(K)
K
00
2761
FRESNIUS HEMOFLOW F7NR, F50NR, F70NR HEMODIALYZERS
2
Cleared 510(K)
K
99
1908
IDEMSA HEMOPHAN HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
99
2594
A-15 HEMODIALYZER
2
Cleared 510(K)
K
99
2565
A-18 HEMODIALYZER
2
Cleared 510(K)
K
99
1512
ASAHI AM-R-SERIES DIALYZERS (MODIFIED), MODEL AM-NR-X
2
Cleared 510(K)
K
99
0159
DYNAMIC HOLLOW FIBER DIALYZER DH-SERIES, MODEL AH 90111
2
Cleared 510(K)
K
98
2337
CUPROPHAN AND HEMOPHAN HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
98
1253
ULTRACON ULTRAFILTRATOR
2
Cleared 510(K)
K
98
0658
PSN DIALYZER, MODEL PSN 130/R5M4233, MODEL PSN-150/R5M4234
2
Cleared 510(K)
K
97
1710
ULTRACON ULTRAFILTRATOR
2
Cleared 510(K)
K
97
3291
DYNAMIC HOLLOW FIBER DIALYZER DC-SERIES
2
Cleared 510(K)
K
97
0708
CLIRANS T-SERIES HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
96
3933
PSN-120 HOLLOW FIBER DIALYZER AND PSN-140 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
96
2309
ALTERNATE ENCAPSULATING RESIN SYSTEM FOR MCA HEMODIALYZERS
2
Cleared 510(K)
K
96
1039
BLLOD PORT CAP, DIALYSATE PORT CAP, VENTED DIALYSATE PORT CAP WITH RED PLIABLE VINYL
2
Cleared 510(K)
K
96
1040
BLOOD PORT CAP, DIALYSATE PORT CAP, RED HARD PLASTIC
2
Cleared 510(K)
K
96
1026
BLOOD PORT CAP, LUER-LOCK FITTING, DAYSPRING MEDICAL PART NO. BPC252LL
2
Cleared 510(K)
K
94
4436
COBE CENTRYSYSTEM CS 200 DIALYZER
2
Cleared 510(K)
K
95
2343
FOCUA 90R, 90HR, 120R, 120HR, 160R, 160HR HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
95
0602
PORT CAPS (PROTECTIVE CLOSURES FOE REPROCESSED HEMODIALYZERS
2
Cleared 510(K)
K
94
5746
GAMBRO LUNDIA 94-500 DIALYZER
2
Cleared 510(K)
K
94
5622
MCA(TM) 180 HEMODIALYZER
2
Cleared 510(K)
K
93
5471
FILTRYZER(TM)
2
Cleared 510(K)
K
94
5631
155 SCE(TM) HEMODIALYZER
2
Cleared 510(K)
K
94
5623
MCA(TM) 130 HEMODIALYZER
2
Cleared 510(K)
K
94
5624
MCA(TM) 160 HEMODIALYZER
2
Cleared 510(K)
K
94
1708
COBE CENTRYSYSTEM CS500 DIALYZER
2
Cleared 510(K)
K
94
0910
FILTRYZER
2
Cleared 510(K)
K
95
0454
CAHP HIGH PERFORMANCE CELLULOSE DIACETATE HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
93
0503
CLIRANS WET PACK HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
92
6372
MCA 200 HEMPDIALYZER
2
Cleared 510(K)
K
92
6567
BAXTER CA DIALYZER
2
Cleared 510(K)
K
92
6005
FRESENIUS HEMOFLOW, VARIOUS MODELS
2
Cleared 510(K)
K
91
4790
HOLLOW FIBER DIALYZER FOCUS 9OR/90H-R/120R/120H-R
2
Cleared 510(K)
K
90
5779
ALDETECT
2
Cleared 510(K)
K
90
4566
NEW COBE CENTRYSYSTEM(TM) 100 HG DIALYZER
2
Cleared 510(K)
K
90
5228
MODEL CA.150 CELLULOSE ACETATE HOLLOW FIBER DIALYZ
2
Cleared 510(K)
K
90
3567
BIO* NEPHROSS ANDANTE, MODERATO, ALLEGIO H.F.
2
Cleared 510(K)
K
90
2481
GAMBRO ALWALL GFS PLUS 11, 16 & 20 HOLLOW FIBER
2
Cleared 510(K)
K
89
3677
HOLLOW FIBER DIALYZER FOCUS 70H
2
Cleared 510(K)
K
89
1477
CLIRANS HOLLOW FIBER HEMODIALYZER (WET)
2
Cleared 510(K)
K
89
2375
MODIFIED AM-SERIES DIALYZERS
2
Cleared 510(K)
K
89
2374
NEW AM-SERIES DIALYZERS
2
Cleared 510(K)
K
89
2523
GAMBRO ALWALL GFS 11,12,PLUS 12 HOLLOW FIBER DIALY
2
Cleared 510(K)
K
88
4339
TORAY FILTRYZER DIALYZERS
2
Cleared 510(K)
K
89
0111
GAMBRO ALWALL GFE 8 & 9 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
88
3748
RENAK-E & RENEK-A SERIES HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
88
3644
CAPILLARY FLOW DIALYZERS MODELS HT. 130 & 170
2
Cleared 510(K)
K
88
3534
CAPILLARY FLOW DIALYZERS MODELS HT.80 & HT.100
2
Cleared 510(K)
K
88
3589
GAMBRO ALWALL GFE 12 & 18 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
88
1811
COBE CENTRYSYSTEM HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
88
2158
MODIFIED TORAY FILTRYZER DIALYZERS
2
Cleared 510(K)
K
88
2680
ALTERNATE BLOOD PORT DESIGN FOR ADDIT. MEMB. OF CA
2
Cleared 510(K)
K
88
2339
BIO*NEPHROSS I.Q. ANDANTE
2
Cleared 510(K)
K
88
2215
NEPHROSS I.Q. MODERATO
2
Cleared 510(K)
K
88
2213
NEPHROSS I.Q. ALLEGO
2
Cleared 510(K)
K
88
0084
GF 120M, 120H, 180M & 180H HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
87
4872
FRESENIUS HEMOFLOW F3, F4, F5, F7
2
Cleared 510(K)
K
87
4728
CAPILLARY FLOW DIALYZERS
2
Cleared 510(K)
K
87
4549
NEPHROSS I.Q. ANDANTE
2
Cleared 510(K)
K
88
0083
GAMBRO ALWALL GFE 11 & 15 HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
87
1471
CAPILLARY FLOW DIALYZERS MODELS ST-12 & ST-15
2
Cleared 510(K)
K
87
1236
HOLLOW FIBER DIALYZER FOCUS 70,90,120,90H,120H
2
Cleared 510(K)
K
87
0725
FRESENIUS HEMOFLOW F6 AND F8
2
Cleared 510(K)
K
87
0169
CAPILLARY FLOW DIALYZERS
2
Cleared 510(K)
K
86
4831
COBE CENTRYSYSTEM 145E,160E,175E,190E DIALYZERS
2
Cleared 510(K)
K
86
3044
CAPILLARY FLOW HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
86
3592
DISSCAP 80E, 110E, 140E, 160E
2
Cleared 510(K)
K
86
2693
TORAY FILTRYZER DIALYZER, B1-2.0.
2
Cleared 510(K)
K
86
1916
ADVANCED PERFORMANCE HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
86
1537
ADVANCED PERFORM HOLLOW FIBER DIALYZER, 019752-5
2
Cleared 510(K)
K
86
1536
ADVANCED PERFORM HOLLOW FIBER DIALYZER, 01-9751-7
2
Cleared 510(K)
K
85
5212
ASAHI AM SERIES DIALYZERS
2
Cleared 510(K)
K
85
4280
CLIRANS TAF HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
85
4575
MODIFIED AM-SERIES DIALYZERS
2
Cleared 510(K)
K
85
3591
DIALYZER, CAPILLARY, HOLLOW FIBER
2
Cleared 510(K)
K
85
1380
DISSCAP 110 DIALYZER
2
Cleared 510(K)
K
85
0865
TORAY INDUSTRIES FILTRYZER HOLLOW FIBER KIDNEY B1-
2
Cleared 510(K)
K
85
0654
TORAY INDUS. FILTRYZER HOLLOW FIBER ARTIFICIAL KID
2
Cleared 510(K)
K
85
0655
TORAY IND. FILTRYZER HOLLOW FIBER ARTIF. KIDNEY B2
2
Cleared 510(K)
K
82
0524
CLIRANS HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
82
1587
ERIKA HPF 50 DIALYZER
2
Cleared 510(K)
K
82
0743
HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
82
1690
ERIKA HPF 100,200,300 DIALYZER
2
Cleared 510(K)
K
82
0304
GAMBRO GF-80-M, GF-80-H HEMODIALYZER
2
Cleared 510(K)
K
81
2353
KF-E SERIES OF HOLLOW FIBER DIALYZERS
2
Cleared 510(K)
K
80
2894
CORDIS DOW C-DAK 1.8MRC ARTIFIC-KIDNEY
2
Cleared 510(K)
K
80
2893
CORDIS DOW C-DAK 1.3MRC ARTIF. KIDNEY
2
Cleared 510(K)
K
80
2613
C-PAK MODEL 12 ARTIFICIAL KIDNEY
2
Cleared 510(K)
K
80
2441
CLIRANS TH10 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
2122
CLIRANS TH13 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
2114
NEPHROSS DIALYZER
2
Cleared 510(K)
K
80
2092
HF-100 DIALYZER
2
Cleared 510(K)
K
80
2466
DISSCAP HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
1559
HOLLO FIBER DIALYZER
2
Cleared 510(K)
K
80
1827
RENAFLO HOLLOW FIBER DIALYZER #100.1
2
Cleared 510(K)
K
80
1825
RENAFLO HOLLOW FIBER DIALYZERS S.M.A.D.
2
Cleared 510(K)
K
80
1826
RENAFLO HOLLOW FIBER DIALYZERS #MP 140
2
Cleared 510(K)
K
80
1194
CLIRANS TE07 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
1192
CLIRANS TE10 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
1178
COBE HF80, CAT. #18-580
2
Cleared 510(K)
K
80
1370
GF-120-L DIALYZER
2
Cleared 510(K)
K
80
1344
EXTRACORPOREALS' ALTERNATE MEMBRANE
2
Cleared 510(K)
K
80
1045
GF120H DIALYZER
2
Cleared 510(K)
K
80
0704
C-DAK TM 2800 ARTIFICIAL KIDNEY
2
Cleared 510(K)
K
80
0336
GAMBRO LUNDIA FIBER
2
Cleared 510(K)
K
80
0549
MODEL TRIEX-L HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
0270
TRIEX-2 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
80
0221
CF/211 CAPILLARY FLOW DIALYZER, #5M1784
2
Cleared 510(K)
K
79
2419
C-DAK 2100 ARTIFICIAL KIDNEY
2
Cleared 510(K)
K
79
1320
ERIKA HPF 100
2
Cleared 510(K)
K
79
1322
ERIKA HPF 300
2
Cleared 510(K)
K
79
1321
ERIKA HPF 200
2
Cleared 510(K)
K
79
0696
RDI-1 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
79
0308
DISPOSABLE DIALYZERS, SD-ID, SD-2D
2
Cleared 510(K)
K
79
0067
FLOW DIALYZER, CF 2300 CAPILLARY
2
Cleared 510(K)
K
78
2151
ARTIFICIAL KIDNEY, C-DAK 0.6D
2
Cleared 510(K)
K
78
1142
DISSCAP
2
Cleared 510(K)
K
78
1058
C-DAK 4000 ARTIFICIAL KIDNEY
2
Cleared 510(K)
K
77
2290
DIALYZER, CAPILATORY, HOLLOW FIBER
2
Cleared 510(K)
K
77
2423
SPIRAFLOW DIALYZERS
2
Cleared 510(K)
K
77
1694
CLIRANS TH 15 HOLLOW FIBER DIALYZER
2
Cleared 510(K)
K
77
0867
DIALYZER, FIBER, HOLLOW
2
Cleared 510(K)
K
77
0734
DIALYZER, FIBER, HOLLOW
2
Cleared 510(K)
K
76
1007
ARTIFICIAL KIDNEY, C-DAK CORDIS DOW
2
Cleared 510(K)
K
76
0252
DIALYZER, HF 130 HOLLOW FIBER
2
Cleared 510(K)
FJJ
Dialyzer, Twin Coil
2
Product Code
FJK
Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
2
Product Code
FJM
Guard, Shunt
2
Product Code
FJN
Stabilizer, Shunt
2
Product Code
FJO
Plier, Tube
1
Product Code
FJP
Adaptor, Y
2
Product Code
FJQ
Connector, Shunt
1
Product Code
FJR
Forceps, Disconnect
1
Product Code
FJS
Catheter, Peritoneal, Long-Term Indwelling
2
Product Code
FJT
Intracatheter, Dialysis
2
Product Code
FJW
Ring, Joint
1
Product Code
FJX
Ring, Crimp
1
Product Code
FJY
Plier, Crimp
1
Product Code
FJZ
Declotting Tray, Kit (Including Contents)
2
Product Code
FKA
Dilator, Vessel
2
Product Code
FKB
Connector, Blood Tubing, Infusion T
2
Product Code
FKC
Clamp, Cannula
1
Product Code
FKD
Canister, Coil
2
Product Code
FKE
Tie, Dialysis
1
Product Code
FKF
Gun, Tie, Dialysis
1
Product Code
FKG
Tray, Start/Stop (Including Contents), Dialysis
1
Product Code
FKH
Solution-Test Standard-Conductivity, Dialysis
2
Product Code
FKI
Set, Dialyzer Holder
2
Product Code
FKJ
Filter, Blood, Dialysis
2
Product Code
FKL
Insert, Pump, Blood
2
Product Code
FKM
Adaptor, Fistula
2
Product Code
FKN
Adaptor, Shunt
2
Product Code
FKO
Catheter, Peritoneal Dialysis, Single Use
2
Product Code
FKP
System, Dialysate Delivery, Single Patient
2
Product Code
FKQ
System, Dialysate Delivery, Central Multiple Patient
2
Product Code
FKR
Subsystem, Proportioning
2
Product Code
FKT
System, Dialysate Delivery, Sorbent Regenerated
2
Product Code
FKW
Tip, Vessel
2
Product Code
FKX
System, Peritoneal, Automatic Delivery
2
Product Code
FKY
Connector, Tubing, Dialysate
2
Product Code
FLA
Monitor, Temperature, Dialysis
2
Product Code
FLB
Meter, Conductivity, Induction, Remote Type
2
Product Code
FLC
Station, Dialysis Control, Negative Pressure Type
2
Product Code
FLD
Apparatus, Hemoperfusion, Sorbent
2
Product Code
FOC
Bag, Urine Collection, Newborn
2
Product Code
FON
Bag, Drainage, With Adhesive, Ostomy
1
Product Code
FPD
Tube, Feeding
2
Product Code
FRQ
Tube, Levine
2
Product Code
GBL
Catheter, Ureteral, General & Plastic Surgery
2
Product Code
GBM
Catheter, Urethral
2
Product Code
GBT
Catheter, Rectal
2
Product Code
GCA
Biliary Catheter For Stone Removal That May Also Allow For Irrigation And Contrast Injection
2
Product Code
GDS
Bag, Stomal
1
Product Code
KDH
Catheter (Gastric, Colonic, Etc.), Irrigation And Aspiration
2
Product Code
KDI
Dialyzer, High Permeability With Or Without Sealed Dialysate System
2
Product Code
KDJ
Set, Administration, For Peritoneal Dialysis, Disposable
2
Product Code
KDK
Container, Transport, Kidney
2
Product Code
KDL
Set, Perfusion, Kidney, Disposable
2
Product Code
KDN
System, Perfusion, Kidney
2
Product Code
KGC
Tube, Gastro-Enterostomy
2
Product Code
KNQ
Dilator, Esophageal
2
Product Code
KNR
Adapter, A-V Shunt Or Fistula
2
Product Code
KNT
Tubes, Gastrointestinal (And Accessories)
2
Product Code
KNX
Collector, Urine, (And Accessories) For Indwelling Catheter
2
Product Code
KNY
Accessories, Catheter, G-U
2
Product Code
KNZ
Accessories, A-V Shunt
2
Product Code
KOB
Catheter, Suprapubic (And Accessories)
2
Product Code
KOC
Accessories, Blood Circuit, Hemodialysis
2
Product Code
KOD
Catheter, Urological
2
Product Code
KOE
Dilator, Urethral
2
Product Code
KPF
System, Dialysate Delivery, Semi-Automatic, Peritoneal
2
Product Code
KPH
Catheter, Rectal For Continent Ileostomy
1
Product Code
KPI
Stimulator, Electrical, Non-Implantable, For Incontinence
2
Product Code
KPL
Colonic Irrigation System
2
Product Code
KPM
Shunt, Peritoneal
2
Product Code
KPO
Dialysate Concentrate For Hemodialysis (Liquid Or Powder)
2
Product Code
KPP
Peritoneal Dialysate Filter
2
Product Code
KQQ
Tubing, Dialysate (And Connector)
2
Product Code
KQR
Detector, Air Or Foam
2
Product Code
KXM
System Accessories, Extracorporeal
2
Product Code
LBW
Set, Dialysis, Single Needle (Co-Axial Flow)
2
Product Code
LCG
Intestinal Splinting Tubes
2
Product Code
LFJ
Catheter, Subclavian
2
Product Code
LFK
Catheter, Femoral
2
Product Code
LIF
Dialyzer Reprocessing System
2
Product Code
LJH
System, Irrigation, Urological
2
Product Code
LKY
Device, External Penile Rigidity
2
Product Code
LLB
System, Blood, Extracorporeal And Accessories
2
Product Code
LNS
Lithotriptor, Extracorporeal Shock-Wave, Urological
2
Product Code
LQR
Dislodger, Stone, Biliary
2
Product Code
LRI
Ph Meter For Dialysis Hydrogen Ion Concentration
2
Product Code
MJC
Catheter, Urological (Antimicrobial) And Accessories
2
Product Code
MLW
Warmer, Peritoneal Dialysate
2
Product Code
MNG
External Urethral Occluder, Urinary Incontinence-Control, Female
1
Product Code
MNV
Strip, Dialysate Ph Indicator
2
Product Code
MON
System, Hemodialysis, Remote Accessories
1
Product Code
MPB
Catheter, Hemodialysis, Non-Implanted
2
Product Code
MQS
System, Hemodialysis, Access Recirculation Monitoring
2
Product Code
MSB
System And Accessories, Isolated Heart, Transport And Preservation
2
Product Code
MSD
Catheter, Hemodialysis, Implanted
2
Product Code
MSE
Hemodialyzer, Re-Use, Low Flux
2
Product Code
MSF
Hemodialyzer, Re-Use, High Flux
2
Product Code
MSY
Strip, Test, Reagent, Residuals For Dialysate, Disinfectant
2
Product Code
MSZ
Strip, Test, Reagent, Residuals For Dialysate
2
Product Code
NAM
Stimulator, Peripheral Nerve, Non-Implanted, For Pelvic Floor Dysfunction
2
Product Code
NDS
Media, Culture, Ex Vivo, Tissue And Cell
2
Product Code
NFK
Kit, Repair, Catheter, Hemodialysis
2
Product Code
NHV
System, Water Purification, General Medical Use
2
Product Code
NIE
Catheter, Hemodialysis, Triple Lumen, Non-Implanted
2
Product Code
NIF
Catheter, Hemodialysis, Triple Lumen, Implanted
2
Product Code
NML
Catheter, Biliary, Reprocessed
2
Product Code
NNE
Needle, Fistula, Reprocessed
2
Product Code
NNG
Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed
2
Product Code
NNW
Bag, Urine Collection, Leg, For External Use, Non-Sterile
1
Product Code
NNX
Device, Incontinence, Urosheath Type, Non-Sterile
1
Product Code
NNY
Sheath, Corrugated Rubber, For Non-Indwelling Catheter, Non-Sterile
1
Product Code
NNZ
System, Urine Drainage, Closed, For Non-Indwelling Catheter, Non-Sterile
1
Product Code
NOA
Device, Paste-On For Incontinence, Non-Sterile
1
Product Code
NOO
Clamp, Dialysis Arm
1
Product Code
NOY
Agents, Embolic, For Treatment Of Benign Prostatic Hyperplasia
2
Product Code
NQJ
Catheter, Hemodialysis, Non-Implanted, Ultrafiltration, For Peripheral Use
2
Product Code
NTZ
Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator
2
Product Code
NUB
Colonic Irrigation System, General Well Being
3
Product Code
NYU
Catheter, Hemodialysis, Implanted, Coated
2
Product Code
NWO
Kit, Catheter, Urinary (Exludes Hiv Testing)
2
Product Code
NWP
Suprapubic Cystostomy Catheter Kit
2
Product Code
NWQ
Kit, Catheter, External, Male (Excludes Hiv Testing)
2
Product Code
NWR
Kit, Catheter, Foley (Excludes Hiv Testing)
2
Product Code
NZU
Collector, Urine, Powered, Non Indwelling Catheter
1
Product Code
ODN
Ultrafiltration-Controlled Nocturnal Dialysate Delivery System
2
Product Code
ODX
Autonomous Extracorporeal Blood Leak Detector/Alarm
2
Product Code
OHR
Catheter Care Tray
2
Product Code
ONW
Hemodialysis System For Home Use
2
Product Code
ONY
Oral Removable Retainer For Weight Management
2
Product Code
PBP
Rectal Insert
2
Product Code
PCU
Pancreatic Stent, Covered, Metallic, Removable
2
Product Code
PEH
Hemodialysis Catheter Luer End Cap
2
Product Code
PEV
Dialysis Administration Kit
2
Product Code
PEW
Implantable Transprostatic Tissue Retractor System
2
Product Code
PFH
Venous Window Needle Guide
2
Product Code
PIA
Vibrator For Climax Control Of Premature Ejaculation
2
Product Code
PID
Esophageal Dilator Balloon With Or Without Electrode Sensors
2
Product Code
PIE
Esophageal Dilator With Balloon And Electrode Sensors
2
Product Code
PIF
Gastrointestinal Tubes With Enteral Specific Connectors
2
Product Code
QGC
Suprapubic Catheter Accessories
1
Product Code
PIH
Urethral Insert With Pump For Bladder Drainage
2
Product Code
PIN
Kidney Perfusion Kit
2
Product Code
PIO
Enteral Specific Transition Connectors
2
Product Code
PJH
Dynamic Rectal Control System
2
Product Code
PKI
Fully Subcutaneous Implanted Hemodialysis Catheter
2
Product Code
PLI
Gastrointestional Tube Holder
2
Product Code
PLQ
Enzyme Packed Cartridge
2
Product Code
PNB
Biliary Stent System For Benign Strictures
2
Product Code
PNG
Peritoneal, Drainage Catheter For Refractory Ascites, Long-Term Indwelling
2
Product Code
PNR
Enteral Syringes With Enteral Specific Connectors
2
Product Code
QFQ
Ingested, Transient, Space Occupying Device For Weight Management And/Or Weight Loss
2
Product Code
PPA
Bladder Irrigation Kit
2
Product Code
PPB
Foley Catheter Kit (Excludes Hiv Testing)
2
Product Code
PPC
Male External Catheterization Kit (Excludes Hiv Testing)
2
Product Code
PPD
Universal Drainage Tray
2
Product Code
PPF
Urinary Irrigation Kit
2
Product Code
PPG
Urinary Drainage Collection Kit
2
Product Code
PPH
Single Needle With Uni-Directional Pump Kit
2
Product Code
PPI
Hemodialysis Tray (Not A Start/Stop Kit)
2
Product Code
PPJ
Peritoneal Dialysis Administration Kit
2
Product Code
PPK
Peritoneal Dialysis Tubing Kit
2
Product Code
PPL
Single Needle (Co-Axial Flow) Dialysis Kit
2
Product Code
PPO
Multi-Lumen Hemodialysis Catheterization Kit
2
Product Code
PQE
Ostomy Care Kit
1
Product Code
PRM
Enteral Administration Kit (Adult & Pediatric)
2
Product Code
PRO
Anti-Regurgitation Blood Tubing Kit
2
Product Code
PRP
Balloon Gastrostomy Tube Kit
2
Product Code
PRQ
Esophageal Dilator Kit
2
Product Code
PRR
Feeding Tube Kit
2
Product Code
PRS
Gastric Colonic Catheter Irrigation Kit
2
Product Code
PRT
Gastric Irrigation And Aspiration Kit
2
Product Code
PRW
Gastrointestinal Tube Kit
2
Product Code
PRX
Gastrostomy Guide Wire Placement Kit
2
Product Code
PRY
Gastrostomy Jejunostomy Feeding Tube Kit
2
Product Code
PRZ
Gastrostomy Tube Kit
2
Product Code
PSA
Laparoscopic Jejunostomy Kit
2
Product Code
PSB
Nasogastric Feed Tube Kit
2
Product Code
PSC
Nasogastric-Gastrojejunal Kit
2
Product Code
PSD
Laparoscopic Gastrostomy Kit
2
Product Code
PSE
Needle Catheter Jejunostomy Kit
2
Product Code
PSF
Non-Balloon Replacement Gastrostomy System
2
Product Code
PSG
Percutaneous Endoscopic Gastrostomy Kit
2
Product Code
PSH
Percutaneous Replacement Gastrostomy Tube Kit
2
Product Code
PSJ
Rectal Dilator Kit
1
Product Code
PSK
Replacement Gastrostomy Feeding Catheter Tray
2
Product Code
PSX
Chlorine Meter
2
Product Code
PTK
Pediatric Esophageal Atresia Anastomosis Device
3
Product Code
PTT
Biliary Catheter For Irrigation And Contrast Injection, Exempt
2
Product Code
PTU
Catheter, Peritoneal, Long-Term Indwelling, Exempt
2
Product Code
PTV
Catheter, Peritoneal Dialysis, Single Use, Exempt
2
Product Code
PTW
System, Peritoneal, Automatic Delivery, Exempt
2
Product Code
QAJ
Cutaneous Electrode Stimulator For Urinary Incontinence
2
Product Code
QAX
Hemodialyzer With Expanded Solute Removal Profile
2
Product Code
QGD
Implanted Mechanical/Hydraulic Urinary Continence Device Surgical Accessories
1
Product Code
QGE
Biliary Stent, Drain, And Dilator Accessories
1
Product Code
QIR
Pediatric Hemodialysis System
2
Product Code
QJN
Laparoscopic Accessories, Esophageal Sizing
2
Product Code
QKA
Temporarily-Placed Urethral Opening System For Symptoms Of Benign Prostatic Hyperplasia
2
Product Code
QMY
Computerized Behavioral Therapy Device For Treating Symptoms
2
Product Code
QON
Implanted Electrical Device Intended For Treatment Of Fecal Incontinence
3
Product Code
QRC
Non-Implanted Electrical Stimulation Device For Management Of Premature Ejaculation
2
Product Code
SCT
Foley Catheters And Accessories With Additional Safety Features
2
Product Code
Subpart G—General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
GU
/
subpart-f—therapeutic-devices
/
FJI
/
K882215
View Source
NEPHROSS I.Q. MODERATO
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K882215
510(k) Type
Traditional
Applicant
ORGANON TEKNIKA CORP.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
6/28/1988
Days to Decision
33 days
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
Miscellaneous
Subpart B—Diagnostic Devices
Subpart B—Obstetrical and Gynecological Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart C—Monitoring Devices
Subpart D—Prosthetic Devices
Subpart E—Obstetrical and Gynecological Surgical Devices
Subpart E—Surgical Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
Subpart F—Therapeutic Devices
EZT
Pacemaker, Bladder
EZW
Stimulator, Electrical, Implantable, For Incontinence
EZY
Device, Incontinence, Mechanical/Hydraulic
FAH
Dilator, Urethral, Mechanical
BSS
Tube, Nasogastric
EXA
Selector, Size, Ostomy
EXB
Collector, Ostomy
EXD
Irrigator, Ostomy
EXE
Protector, Ostomy
EXF
Bag, Bile Collecting
EXG
Bag, Urine Collecting, Ureterostomy
EXH
Bag, Urinary, Ileostomy
EXI
Device, Paste-On For Incontinence, Sterile
EXJ
Device, Incontinence, Urosheath Type, Sterile
EXN
Support, Hernia
EYA
Stylet, Ureteral
EYB
Catheter, Ureteral, Gastro-Urology
EYC
Catheter, Upper Urinary Tract
EYI
Adaptor, Ureteral Catheter
EYJ
Holder, Ureteral Catheter
EYK
Connector, Ureteral Catheter
EYQ
Garment, Protective, For Incontinence
EYT
Sheath, Corrugated Rubber, For Nonindwelling Catheter, Sterile
EYZ
System, Urine Drainage, Closed, For Nonindwelling Catheter, Sterile
EZB
Stylet For Catheter, Gastro-Urology
EZC
Catheter, Coude
EZD
Catheter, Straight
EZK
Catheter, Retention Type
EZL
Catheter, Retention Type, Balloon
EZM
Dilator, Esophageal (Metal Olive) Gastro-Urology
EZN
Dilator, Catheter, Ureteral
EZQ
Pouch, Colostomy
EZR
Cement, Stomal Appliance, Ostomy
EZS
Appliance, Colostomy, Disposable
FAQ
Bag, Urine Collection, Leg, For External Use, Sterile
FAT
Bougie, Esophageal, And Gastrointestinal, Gastro-Urology
FAX
Bougie, Urological
FBM
Cannula And Trocar, Suprapubic, Non-Disposable
FBR
Urethrometer
FBW
Filiform And Filiform Follower
FBX
Sound, Urethral, Metal Or Plastic
FCB
Bag, Hemostatic
FCE
Enema Kit
FCM
Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)
FCN
Urinary Drainage Collection Kit, For Indwelling Catheter
FEF
Tube, Single Lumen, With Mercury Wt Balloon For Intestinal Intubation And / Or Decompression
FEG
Tube, Double Lumen For Intestinal Decompression And/Or Intubation
FEW
Catheter, Malecot
FEX
Instrument, Catheter, Punch
FEZ
Catheter And Tube, Suprapubic
FFA
Tube, Drainage, Suprapubic
FFH
Collector, Urine, Pediatric, For Indwelling Catheter
FFP
Dilator, Rectal
FFW
String And Tubes, Gastrointestinal, To Locate Internal Bleeding
FGD
Catheter, Retention, Barium Enema With Bag
FGE
Stents, Drains And Dilators For The Biliary Ducts
FGF
Catheter, Ureteral Disposable (X-Ray)
FGH
Catheter, Double Lumen Female Urethrographic
FGI
Catheter, Urethrographic, Male
FHA
Clamp, Penile
FHS
Dialyzer, Single Coil
FHT
Set, Gavage, Infant, Sterile
FIA
Chair, Dialysis, Unpowered, Without Scales
FIB
Protector, Transducer, Dialysis
FID
Tubing, Dialysate
FIE
Needle, Fistula
FIF
Set, Dialysis, Single Needle With Uni-Directional Pump
FIG
Clamp, Tubing, Blood, Automatic
FIH
Pump, Infusion Or Syringe, Extra-Luminal
FII
System, Dialysate Delivery, Sealed
FIJ
System, Dialysate Delivery, Recirculating, Single Pass
FIK
System, Dialysate Delivery, Recirculating
FIL
System, Dialysate Delivery, Single Pass
FIN
Tank, Holding, Dialysis
FIP
Subsystem, Water Purification
FIQ
Cannula, A-V Shunt
FIR
Pump, Blood, Extra-Luminal
FIS
Flowmeter, Dialysate
FIW
Alarm, Pillow Pressure
FIZ
Meter, Conductivity, Non-Remote
FJA
Manometer, Water
FJB
Detector, Dialysate Level
FJC
Detector, Blood Level
FJD
Detector, Leak, Blood
FJF
Detector, Air Bubble
FJG
Dialyzer, Parallel Flow
FJH
Dialyzer, Disposable
FJI
Dialyzer, Capillary, Hollow Fiber
K
19
0459
Hemoflow F3 and F4 Dialyzers
K
12
2952
NIPRO PUREFLUX-L HEMODIALYZER
K
04
3342
POLYFLUX FAMILY HEMODIALYZER/FILTER LABELED FOR SINGLE AND MULTIPLE USE, MODELS 14L, 17L, 21L, 140H, 170H, 210H,6LR, 8LR
K
01
0366
DISPOSABLE STORAGE CAP
K
01
1148
ULTRACONCENTRATOR SYSTEM
K
00
2761
FRESNIUS HEMOFLOW F7NR, F50NR, F70NR HEMODIALYZERS
K
99
1908
IDEMSA HEMOPHAN HOLLOW FIBER DIALYZERS
K
99
2594
A-15 HEMODIALYZER
K
99
2565
A-18 HEMODIALYZER
K
99
1512
ASAHI AM-R-SERIES DIALYZERS (MODIFIED), MODEL AM-NR-X
K
99
0159
DYNAMIC HOLLOW FIBER DIALYZER DH-SERIES, MODEL AH 90111
K
98
2337
CUPROPHAN AND HEMOPHAN HOLLOW FIBER DIALYZER
K
98
1253
ULTRACON ULTRAFILTRATOR
K
98
0658
PSN DIALYZER, MODEL PSN 130/R5M4233, MODEL PSN-150/R5M4234
K
97
1710
ULTRACON ULTRAFILTRATOR
K
97
3291
DYNAMIC HOLLOW FIBER DIALYZER DC-SERIES
K
97
0708
CLIRANS T-SERIES HOLLOW FIBER DIALYZERS
K
96
3933
PSN-120 HOLLOW FIBER DIALYZER AND PSN-140 HOLLOW FIBER DIALYZER
K
96
2309
ALTERNATE ENCAPSULATING RESIN SYSTEM FOR MCA HEMODIALYZERS
K
96
1039
BLLOD PORT CAP, DIALYSATE PORT CAP, VENTED DIALYSATE PORT CAP WITH RED PLIABLE VINYL
K
96
1040
BLOOD PORT CAP, DIALYSATE PORT CAP, RED HARD PLASTIC
K
96
1026
BLOOD PORT CAP, LUER-LOCK FITTING, DAYSPRING MEDICAL PART NO. BPC252LL
K
94
4436
COBE CENTRYSYSTEM CS 200 DIALYZER
K
95
2343
FOCUA 90R, 90HR, 120R, 120HR, 160R, 160HR HOLLOW FIBER DIALYZER
K
95
0602
PORT CAPS (PROTECTIVE CLOSURES FOE REPROCESSED HEMODIALYZERS
K
94
5746
GAMBRO LUNDIA 94-500 DIALYZER
K
94
5622
MCA(TM) 180 HEMODIALYZER
K
93
5471
FILTRYZER(TM)
K
94
5631
155 SCE(TM) HEMODIALYZER
K
94
5623
MCA(TM) 130 HEMODIALYZER
K
94
5624
MCA(TM) 160 HEMODIALYZER
K
94
1708
COBE CENTRYSYSTEM CS500 DIALYZER
K
94
0910
FILTRYZER
K
95
0454
CAHP HIGH PERFORMANCE CELLULOSE DIACETATE HOLLOW FIBER DIALYZER
K
93
0503
CLIRANS WET PACK HOLLOW FIBER DIALYZER
K
92
6372
MCA 200 HEMPDIALYZER
K
92
6567
BAXTER CA DIALYZER
K
92
6005
FRESENIUS HEMOFLOW, VARIOUS MODELS
K
91
4790
HOLLOW FIBER DIALYZER FOCUS 9OR/90H-R/120R/120H-R
K
90
5779
ALDETECT
K
90
4566
NEW COBE CENTRYSYSTEM(TM) 100 HG DIALYZER
K
90
5228
MODEL CA.150 CELLULOSE ACETATE HOLLOW FIBER DIALYZ
K
90
3567
BIO* NEPHROSS ANDANTE, MODERATO, ALLEGIO H.F.
K
90
2481
GAMBRO ALWALL GFS PLUS 11, 16 & 20 HOLLOW FIBER
K
89
3677
HOLLOW FIBER DIALYZER FOCUS 70H
K
89
1477
CLIRANS HOLLOW FIBER HEMODIALYZER (WET)
K
89
2375
MODIFIED AM-SERIES DIALYZERS
K
89
2374
NEW AM-SERIES DIALYZERS
K
89
2523
GAMBRO ALWALL GFS 11,12,PLUS 12 HOLLOW FIBER DIALY
K
88
4339
TORAY FILTRYZER DIALYZERS
K
89
0111
GAMBRO ALWALL GFE 8 & 9 HOLLOW FIBER DIALYZER
K
88
3748
RENAK-E & RENEK-A SERIES HOLLOW FIBER DIALYZERS
K
88
3644
CAPILLARY FLOW DIALYZERS MODELS HT. 130 & 170
K
88
3534
CAPILLARY FLOW DIALYZERS MODELS HT.80 & HT.100
K
88
3589
GAMBRO ALWALL GFE 12 & 18 HOLLOW FIBER DIALYZER
K
88
1811
COBE CENTRYSYSTEM HOLLOW FIBER DIALYZERS
K
88
2158
MODIFIED TORAY FILTRYZER DIALYZERS
K
88
2680
ALTERNATE BLOOD PORT DESIGN FOR ADDIT. MEMB. OF CA
K
88
2339
BIO*NEPHROSS I.Q. ANDANTE
K
88
2215
NEPHROSS I.Q. MODERATO
K
88
2213
NEPHROSS I.Q. ALLEGO
K
88
0084
GF 120M, 120H, 180M & 180H HOLLOW FIBER DIALYZERS
K
87
4872
FRESENIUS HEMOFLOW F3, F4, F5, F7
K
87
4728
CAPILLARY FLOW DIALYZERS
K
87
4549
NEPHROSS I.Q. ANDANTE
K
88
0083
GAMBRO ALWALL GFE 11 & 15 HOLLOW FIBER DIALYZERS
K
87
1471
CAPILLARY FLOW DIALYZERS MODELS ST-12 & ST-15
K
87
1236
HOLLOW FIBER DIALYZER FOCUS 70,90,120,90H,120H
K
87
0725
FRESENIUS HEMOFLOW F6 AND F8
K
87
0169
CAPILLARY FLOW DIALYZERS
K
86
4831
COBE CENTRYSYSTEM 145E,160E,175E,190E DIALYZERS
K
86
3044
CAPILLARY FLOW HOLLOW FIBER DIALYZERS
K
86
3592
DISSCAP 80E, 110E, 140E, 160E
K
86
2693
TORAY FILTRYZER DIALYZER, B1-2.0.
K
86
1916
ADVANCED PERFORMANCE HOLLOW FIBER DIALYZER
K
86
1537
ADVANCED PERFORM HOLLOW FIBER DIALYZER, 019752-5
K
86
1536
ADVANCED PERFORM HOLLOW FIBER DIALYZER, 01-9751-7
K
85
5212
ASAHI AM SERIES DIALYZERS
K
85
4280
CLIRANS TAF HOLLOW FIBER DIALYZER
K
85
4575
MODIFIED AM-SERIES DIALYZERS
K
85
3591
DIALYZER, CAPILLARY, HOLLOW FIBER
K
85
1380
DISSCAP 110 DIALYZER
K
85
0865
TORAY INDUSTRIES FILTRYZER HOLLOW FIBER KIDNEY B1-
K
85
0654
TORAY INDUS. FILTRYZER HOLLOW FIBER ARTIFICIAL KID
K
85
0655
TORAY IND. FILTRYZER HOLLOW FIBER ARTIF. KIDNEY B2
K
82
0524
CLIRANS HOLLOW FIBER DIALYZERS
K
82
1587
ERIKA HPF 50 DIALYZER
K
82
0743
HOLLOW FIBER DIALYZERS
K
82
1690
ERIKA HPF 100,200,300 DIALYZER
K
82
0304
GAMBRO GF-80-M, GF-80-H HEMODIALYZER
K
81
2353
KF-E SERIES OF HOLLOW FIBER DIALYZERS
K
80
2894
CORDIS DOW C-DAK 1.8MRC ARTIFIC-KIDNEY
K
80
2893
CORDIS DOW C-DAK 1.3MRC ARTIF. KIDNEY
K
80
2613
C-PAK MODEL 12 ARTIFICIAL KIDNEY
K
80
2441
CLIRANS TH10 HOLLOW FIBER DIALYZER
K
80
2122
CLIRANS TH13 HOLLOW FIBER DIALYZER
K
80
2114
NEPHROSS DIALYZER
K
80
2092
HF-100 DIALYZER
K
80
2466
DISSCAP HOLLOW FIBER DIALYZER
K
80
1559
HOLLO FIBER DIALYZER
K
80
1827
RENAFLO HOLLOW FIBER DIALYZER #100.1
K
80
1825
RENAFLO HOLLOW FIBER DIALYZERS S.M.A.D.
K
80
1826
RENAFLO HOLLOW FIBER DIALYZERS #MP 140
K
80
1194
CLIRANS TE07 HOLLOW FIBER DIALYZER
K
80
1192
CLIRANS TE10 HOLLOW FIBER DIALYZER
K
80
1178
COBE HF80, CAT. #18-580
K
80
1370
GF-120-L DIALYZER
K
80
1344
EXTRACORPOREALS' ALTERNATE MEMBRANE
K
80
1045
GF120H DIALYZER
K
80
0704
C-DAK TM 2800 ARTIFICIAL KIDNEY
K
80
0336
GAMBRO LUNDIA FIBER
K
80
0549
MODEL TRIEX-L HOLLOW FIBER DIALYZER
K
80
0270
TRIEX-2 HOLLOW FIBER DIALYZER
K
80
0221
CF/211 CAPILLARY FLOW DIALYZER, #5M1784
K
79
2419
C-DAK 2100 ARTIFICIAL KIDNEY
K
79
1320
ERIKA HPF 100
K
79
1322
ERIKA HPF 300
K
79
1321
ERIKA HPF 200
K
79
0696
RDI-1 HOLLOW FIBER DIALYZER
K
79
0308
DISPOSABLE DIALYZERS, SD-ID, SD-2D
K
79
0067
FLOW DIALYZER, CF 2300 CAPILLARY
K
78
2151
ARTIFICIAL KIDNEY, C-DAK 0.6D
K
78
1142
DISSCAP
K
78
1058
C-DAK 4000 ARTIFICIAL KIDNEY
K
77
2290
DIALYZER, CAPILATORY, HOLLOW FIBER
K
77
2423
SPIRAFLOW DIALYZERS
K
77
1694
CLIRANS TH 15 HOLLOW FIBER DIALYZER
K
77
0867
DIALYZER, FIBER, HOLLOW
K
77
0734
DIALYZER, FIBER, HOLLOW
K
76
1007
ARTIFICIAL KIDNEY, C-DAK CORDIS DOW
K
76
0252
DIALYZER, HF 130 HOLLOW FIBER
FJJ
Dialyzer, Twin Coil
FJK
Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
FJM
Guard, Shunt
FJN
Stabilizer, Shunt
FJO
Plier, Tube
FJP
Adaptor, Y
FJQ
Connector, Shunt
FJR
Forceps, Disconnect
FJS
Catheter, Peritoneal, Long-Term Indwelling
FJT
Intracatheter, Dialysis
FJW
Ring, Joint
FJX
Ring, Crimp
FJY
Plier, Crimp
FJZ
Declotting Tray, Kit (Including Contents)
FKA
Dilator, Vessel
FKB
Connector, Blood Tubing, Infusion T
FKC
Clamp, Cannula
FKD
Canister, Coil
FKE
Tie, Dialysis
FKF
Gun, Tie, Dialysis
FKG
Tray, Start/Stop (Including Contents), Dialysis
FKH
Solution-Test Standard-Conductivity, Dialysis
FKI
Set, Dialyzer Holder
FKJ
Filter, Blood, Dialysis
FKL
Insert, Pump, Blood
FKM
Adaptor, Fistula
FKN
Adaptor, Shunt
FKO
Catheter, Peritoneal Dialysis, Single Use
FKP
System, Dialysate Delivery, Single Patient
FKQ
System, Dialysate Delivery, Central Multiple Patient
FKR
Subsystem, Proportioning
FKT
System, Dialysate Delivery, Sorbent Regenerated
FKW
Tip, Vessel
FKX
System, Peritoneal, Automatic Delivery
FKY
Connector, Tubing, Dialysate
FLA
Monitor, Temperature, Dialysis
FLB
Meter, Conductivity, Induction, Remote Type
FLC
Station, Dialysis Control, Negative Pressure Type
FLD
Apparatus, Hemoperfusion, Sorbent
FOC
Bag, Urine Collection, Newborn
FON
Bag, Drainage, With Adhesive, Ostomy
FPD
Tube, Feeding
FRQ
Tube, Levine
GBL
Catheter, Ureteral, General & Plastic Surgery
GBM
Catheter, Urethral
GBT
Catheter, Rectal
GCA
Biliary Catheter For Stone Removal That May Also Allow For Irrigation And Contrast Injection
GDS
Bag, Stomal
KDH
Catheter (Gastric, Colonic, Etc.), Irrigation And Aspiration
KDI
Dialyzer, High Permeability With Or Without Sealed Dialysate System
KDJ
Set, Administration, For Peritoneal Dialysis, Disposable
KDK
Container, Transport, Kidney
KDL
Set, Perfusion, Kidney, Disposable
KDN
System, Perfusion, Kidney
KGC
Tube, Gastro-Enterostomy
KNQ
Dilator, Esophageal
KNR
Adapter, A-V Shunt Or Fistula
KNT
Tubes, Gastrointestinal (And Accessories)
KNX
Collector, Urine, (And Accessories) For Indwelling Catheter
KNY
Accessories, Catheter, G-U
KNZ
Accessories, A-V Shunt
KOB
Catheter, Suprapubic (And Accessories)
KOC
Accessories, Blood Circuit, Hemodialysis
KOD
Catheter, Urological
KOE
Dilator, Urethral
KPF
System, Dialysate Delivery, Semi-Automatic, Peritoneal
KPH
Catheter, Rectal For Continent Ileostomy
KPI
Stimulator, Electrical, Non-Implantable, For Incontinence
KPL
Colonic Irrigation System
KPM
Shunt, Peritoneal
KPO
Dialysate Concentrate For Hemodialysis (Liquid Or Powder)
KPP
Peritoneal Dialysate Filter
KQQ
Tubing, Dialysate (And Connector)
KQR
Detector, Air Or Foam
KXM
System Accessories, Extracorporeal
LBW
Set, Dialysis, Single Needle (Co-Axial Flow)
LCG
Intestinal Splinting Tubes
LFJ
Catheter, Subclavian
LFK
Catheter, Femoral
LIF
Dialyzer Reprocessing System
LJH
System, Irrigation, Urological
LKY
Device, External Penile Rigidity
LLB
System, Blood, Extracorporeal And Accessories
LNS
Lithotriptor, Extracorporeal Shock-Wave, Urological
LQR
Dislodger, Stone, Biliary
LRI
Ph Meter For Dialysis Hydrogen Ion Concentration
MJC
Catheter, Urological (Antimicrobial) And Accessories
MLW
Warmer, Peritoneal Dialysate
MNG
External Urethral Occluder, Urinary Incontinence-Control, Female
MNV
Strip, Dialysate Ph Indicator
MON
System, Hemodialysis, Remote Accessories
MPB
Catheter, Hemodialysis, Non-Implanted
MQS
System, Hemodialysis, Access Recirculation Monitoring
MSB
System And Accessories, Isolated Heart, Transport And Preservation
MSD
Catheter, Hemodialysis, Implanted
MSE
Hemodialyzer, Re-Use, Low Flux
MSF
Hemodialyzer, Re-Use, High Flux
MSY
Strip, Test, Reagent, Residuals For Dialysate, Disinfectant
MSZ
Strip, Test, Reagent, Residuals For Dialysate
NAM
Stimulator, Peripheral Nerve, Non-Implanted, For Pelvic Floor Dysfunction
NDS
Media, Culture, Ex Vivo, Tissue And Cell
NFK
Kit, Repair, Catheter, Hemodialysis
NHV
System, Water Purification, General Medical Use
NIE
Catheter, Hemodialysis, Triple Lumen, Non-Implanted
NIF
Catheter, Hemodialysis, Triple Lumen, Implanted
NML
Catheter, Biliary, Reprocessed
NNE
Needle, Fistula, Reprocessed
NNG
Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed
NNW
Bag, Urine Collection, Leg, For External Use, Non-Sterile
NNX
Device, Incontinence, Urosheath Type, Non-Sterile
NNY
Sheath, Corrugated Rubber, For Non-Indwelling Catheter, Non-Sterile
NNZ
System, Urine Drainage, Closed, For Non-Indwelling Catheter, Non-Sterile
NOA
Device, Paste-On For Incontinence, Non-Sterile
NOO
Clamp, Dialysis Arm
NOY
Agents, Embolic, For Treatment Of Benign Prostatic Hyperplasia
NQJ
Catheter, Hemodialysis, Non-Implanted, Ultrafiltration, For Peripheral Use
NTZ
Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator
NUB
Colonic Irrigation System, General Well Being
NYU
Catheter, Hemodialysis, Implanted, Coated
NWO
Kit, Catheter, Urinary (Exludes Hiv Testing)
NWP
Suprapubic Cystostomy Catheter Kit
NWQ
Kit, Catheter, External, Male (Excludes Hiv Testing)
NWR
Kit, Catheter, Foley (Excludes Hiv Testing)
NZU
Collector, Urine, Powered, Non Indwelling Catheter
ODN
Ultrafiltration-Controlled Nocturnal Dialysate Delivery System
ODX
Autonomous Extracorporeal Blood Leak Detector/Alarm
OHR
Catheter Care Tray
ONW
Hemodialysis System For Home Use
ONY
Oral Removable Retainer For Weight Management
PBP
Rectal Insert
PCU
Pancreatic Stent, Covered, Metallic, Removable
PEH
Hemodialysis Catheter Luer End Cap
PEV
Dialysis Administration Kit
PEW
Implantable Transprostatic Tissue Retractor System
PFH
Venous Window Needle Guide
PIA
Vibrator For Climax Control Of Premature Ejaculation
PID
Esophageal Dilator Balloon With Or Without Electrode Sensors
PIE
Esophageal Dilator With Balloon And Electrode Sensors
PIF
Gastrointestinal Tubes With Enteral Specific Connectors
QGC
Suprapubic Catheter Accessories
PIH
Urethral Insert With Pump For Bladder Drainage
PIN
Kidney Perfusion Kit
PIO
Enteral Specific Transition Connectors
PJH
Dynamic Rectal Control System
PKI
Fully Subcutaneous Implanted Hemodialysis Catheter
PLI
Gastrointestional Tube Holder
PLQ
Enzyme Packed Cartridge
PNB
Biliary Stent System For Benign Strictures
PNG
Peritoneal, Drainage Catheter For Refractory Ascites, Long-Term Indwelling
PNR
Enteral Syringes With Enteral Specific Connectors
QFQ
Ingested, Transient, Space Occupying Device For Weight Management And/Or Weight Loss
PPA
Bladder Irrigation Kit
PPB
Foley Catheter Kit (Excludes Hiv Testing)
PPC
Male External Catheterization Kit (Excludes Hiv Testing)
PPD
Universal Drainage Tray
PPF
Urinary Irrigation Kit
PPG
Urinary Drainage Collection Kit
PPH
Single Needle With Uni-Directional Pump Kit
PPI
Hemodialysis Tray (Not A Start/Stop Kit)
PPJ
Peritoneal Dialysis Administration Kit
PPK
Peritoneal Dialysis Tubing Kit
PPL
Single Needle (Co-Axial Flow) Dialysis Kit
PPO
Multi-Lumen Hemodialysis Catheterization Kit
PQE
Ostomy Care Kit
PRM
Enteral Administration Kit (Adult & Pediatric)
PRO
Anti-Regurgitation Blood Tubing Kit
PRP
Balloon Gastrostomy Tube Kit
PRQ
Esophageal Dilator Kit
PRR
Feeding Tube Kit
PRS
Gastric Colonic Catheter Irrigation Kit
PRT
Gastric Irrigation And Aspiration Kit
PRW
Gastrointestinal Tube Kit
PRX
Gastrostomy Guide Wire Placement Kit
PRY
Gastrostomy Jejunostomy Feeding Tube Kit
PRZ
Gastrostomy Tube Kit
PSA
Laparoscopic Jejunostomy Kit
PSB
Nasogastric Feed Tube Kit
PSC
Nasogastric-Gastrojejunal Kit
PSD
Laparoscopic Gastrostomy Kit
PSE
Needle Catheter Jejunostomy Kit
PSF
Non-Balloon Replacement Gastrostomy System
PSG
Percutaneous Endoscopic Gastrostomy Kit
PSH
Percutaneous Replacement Gastrostomy Tube Kit
PSJ
Rectal Dilator Kit
PSK
Replacement Gastrostomy Feeding Catheter Tray
PSX
Chlorine Meter
PTK
Pediatric Esophageal Atresia Anastomosis Device
PTT
Biliary Catheter For Irrigation And Contrast Injection, Exempt
PTU
Catheter, Peritoneal, Long-Term Indwelling, Exempt
PTV
Catheter, Peritoneal Dialysis, Single Use, Exempt
PTW
System, Peritoneal, Automatic Delivery, Exempt
QAJ
Cutaneous Electrode Stimulator For Urinary Incontinence
QAX
Hemodialyzer With Expanded Solute Removal Profile
QGD
Implanted Mechanical/Hydraulic Urinary Continence Device Surgical Accessories
QGE
Biliary Stent, Drain, And Dilator Accessories
QIR
Pediatric Hemodialysis System
QJN
Laparoscopic Accessories, Esophageal Sizing
QKA
Temporarily-Placed Urethral Opening System For Symptoms Of Benign Prostatic Hyperplasia
QMY
Computerized Behavioral Therapy Device For Treating Symptoms
QON
Implanted Electrical Device Intended For Treatment Of Fecal Incontinence
QRC
Non-Implanted Electrical Stimulation Device For Management Of Premature Ejaculation
SCT
Foley Catheters And Accessories With Additional Safety Features
Subpart G—General Hospital and Personal Use Miscellaneous Devices
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
GU
/
subpart-f—therapeutic-devices
/
FJI
/
K882215
View Source
NEPHROSS I.Q. MODERATO
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K882215
510(k) Type
Traditional
Applicant
ORGANON TEKNIKA CORP.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
6/28/1988
Days to Decision
33 days