MSY · Strip, Test, Reagent, Residuals For Dialysate, Disinfectant

Gastroenterology, Urology · 21 CFR 876.5665 · Class 2

Overview

Product CodeMSY
Device NameStrip, Test, Reagent, Residuals For Dialysate, Disinfectant
Regulation21 CFR 876.5665
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A water purification system for hemodialysis is a device that is intended for use with a hemodialysis system and that is intended to remove organic and inorganic substances and microbial contaminants from water used to dilute dialysate concentrate to form dialysate. This generic type of device may include a water softener, sediment filter, carbon filter, and water distillation system.

Classification Rationale

Class II (special controls). The device, when it is a water purification subsystem disinfectant, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Special Controls

*Classification.* Class II (special controls). The device, when it is a water purification subsystem disinfectant, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (13 of 13)

RecordDevice NameApplicantDecision DateDecision
K243898Chlorine Sentinel IINelson Environmental Technologies, Inc.Apr 11, 2025SESE
K222167E-Z Chek Chlorine Residual Test Strips (K100-0101B)Reprocessing Products Corporation (Rpc)Oct 18, 2022SESE
K193169Nelson Sentinel Series Basic Chlorine SentinelNelson Environmental Technologies, Inc.Oct 29, 2020SESE
K132344E-Z CHECK OZONE TEST STRIPSReprocessing Products Corporation (Rpc)Feb 25, 2014SESE
K090338ULTRA LOW TOTAL CHLORINE, E-Z CHEK SENSITIVE TOTAL CHLORINEReprocessing Products CorpMay 8, 2009SESE
K080712SERIM HISENSE ULTRA 0.1, PART NUMBER 5167Serim Research Corp.May 6, 2008SESE
K002011GLUTARTEST 1 REAGENT STRIPIntegrated Biomedical Technology, Inc.Jan 22, 2001SESE
K001194STERICHEK TOTAL CHLORINE REAGENT STRIPSEnvironmental Test Systems, Inc.Jul 11, 2000SESE
K994226STERICHEK TOTAL CHLORINE REAGENT STRIPSEnvironmental Test Systems, Inc.Mar 22, 2000SESE
K983997STERICHEK TOTAL CHLORINE TEST KITEnvironmental Test Systems, Inc.Apr 2, 1999SESE
K974064MICRO X RESIDUAL TEST STRIPSReprocessing Products CorpDec 7, 1998SESE
K980164STERICHEK PERACETIC ACID REAGENT STRIPSEnvironmental Test Systems, Inc.Apr 16, 1998SESE
K971598STERICHEK CHLORINE REAGENT STRIPSEnvironmental Test Systems, Inc.Jul 18, 1997SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...