DRYASOL ACID CONCENTRATE MIX
Device Facts
| Record ID | K993212 |
|---|---|
| Device Name | DRYASOL ACID CONCENTRATE MIX |
| Applicant | Diasol, Inc. |
| Product Code | KPO · Gastroenterology, Urology |
| Decision Date | Oct 22, 1999 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 876.5820 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
Dryasol Acid Concentrate mix is indicated for use in acute and chronic hemodialysis. It is an accessory to be used with the appropriate hemodialysis machine in the exact prescribed proportion with RO water and Sodium Bicarbonate Mix.
Device Story
Dryasol Acid Concentrate is a chemical accessory for hemodialysis machines. It is mixed with RO water and Sodium Bicarbonate to create the dialysate solution required for hemodialysis treatment. Used in clinical settings by trained healthcare professionals to support renal replacement therapy in patients with acute or chronic kidney failure.
Clinical Evidence
No clinical data provided; device is a chemical concentrate accessory for hemodialysis.
Technological Characteristics
Chemical concentrate for hemodialysis; intended for dilution with RO water and Sodium Bicarbonate; regulated under 21 CFR 876.5820.
Indications for Use
Indicated for patients requiring acute or chronic hemodialysis.
Regulatory Classification
Identification
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.
Related Devices
- K052253 — MODIFICATION TO: DRYAC ACID CONCENTRATE MIX FOR BICARBONATE HEMODIALYSIS · Gambro Renal Products · Nov 2, 2005
- K070177 — FRESENIUS NATURALYTE LIQUID ACID CONCENTRATE, 9000, 6000 AND 4000 SERIES · Fresenius Medical Care North America · Mar 29, 2007
- K990507 — ACID CONCENTRATE AND POWDER, ACETATE CONCENTRATE LIQUID AND POWDER, AND BICARBONATE CONCENTRATE LIQUID AND POWDER · Althin Biopharm, Inc. · May 7, 1999
- K981003 — ROCKWELL MEDICAL SUPPLY, LLC. DRI-SATE ACID CONCENTRATE MIXES · International Medical Products, Inc. · Jun 16, 1998
- K131611 — FRESENIUS DRY ACID DISSOLUTION UNITS · Fresenius Medical Care North America · Aug 29, 2013