G.E.M. WATER SYSTEMS, INTERNATIONAL
Device Facts
| Record ID | K970674 |
|---|---|
| Device Name | G.E.M. WATER SYSTEMS, INTERNATIONAL |
| Applicant | G.E.M. Water Systems |
| Product Code | FIN · Gastroenterology, Urology |
| Decision Date | Nov 19, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.5820 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
THE INTENDED USE OF THESE DEVICES IS ALLOW THE HEMODIALYSIS FACILITY TO MIX SODIUM BICARBONATE POWDER WITH PRUIFIED WATER THAT MEETS AAMI STANDARDS FOR HEMODIALYSIS TREATMENT, AND ALLOW THE MIXED SOLUTION TO BE AUTOMATICALLY DELIVERED TO THE DIALYSIS MACHINES.
Device Story
Device mixes sodium bicarbonate powder with purified water (AAMI standard compliant) for hemodialysis; automatically delivers resulting solution to dialysis machines. Used in clinical hemodialysis facilities; operated by trained facility staff. Automates preparation and distribution process; ensures consistent solution delivery to dialysis equipment; supports hemodialysis treatment workflow.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
System for mixing and automated delivery of sodium bicarbonate solution. Uses purified water meeting AAMI standards. Mechanical mixing and fluid delivery components.
Indications for Use
Indicated for use in hemodialysis facilities to prepare and deliver sodium bicarbonate solution for hemodialysis treatment.
Regulatory Classification
Identification
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.
Related Devices
- K022521 — BICARBONATE DIALYSATE CONCENTRATE MIXER, MODEL 50 GALLON & 100 GALLON · Rockwell Medical Technologies, Inc. · Jan 3, 2003
- K033118 — BIPRO MODEL SDS-CB200 · Medical Solutions International · Jun 28, 2004
- K051031 — AMERIWATER SOLUTION MIX AND DISTRIBUTION SYSTEM FOR HEMODIALYSIS · Ameriwater · Jan 6, 2006
- K030366 — BICARD MIXING SYSTEM · Dialysis Systems, Inc. · Apr 19, 2004
- K023011 — OSMONICS SOLUTION DELIVERY SYSTEM · Osmonics Medical Systems · Jun 26, 2003