SHL · Ear, Nose, And Throat Image Analyzer

Ear, Nose, Throat · 21 CFR 874.4775 · Class 2

Overview

Product CodeSHL
Device NameEar, Nose, And Throat Image Analyzer
Regulation21 CFR 874.4775
Device ClassClass 2
Review PanelEar, Nose, Throat

Identification

Tyto Insights for Eardrum Bulging Detection is an over-the-counter web-based AI-enabled software analytics device intended to automatically detect the bulging of the eardrum in Oroscopic video recordings acquired by the compatible electronic otoscope, as identified in the product labeling, in patients aged 6 months and older. The device is not intended for diagnosis. A healthcare provider's advice is required to understand the meaning of the Tyto Insights for Eardrum Bulging Detection result. Healthcare providers should consider the device result in conjunction with otoscopic recordings and other relevant patient data. The device is not intended to detect other abnormal otoscopic findings.

Classification Rationale

FDA has determined that, for the previously stated indications for use, the Tyto Insights for Eardrum Bulging Detection can be classified in class II with the establishment of special controls for class II. FDA believes that class II (special) controls provide reasonable assurance of the safety and effectiveness of the device type.

Special Controls

In combination with the general controls of the FD&C Act, the ear, nose, and throat image analyzer is subject to the following special controls: (1) Clinical performance testing must demonstrate the accuracy and precision of the device output to demonstrate that the device performs as intended under anticipated conditions of use in the intended patient population for the stated indications for use. (2) Human factors/usability testing must demonstrate that the user can correctly use the device, based solely on reading the directions for use. (3) Software verification, validation, and hazard analysis must be performed. (4) Labeling must include: (i) Hardware compatibility information; (ii) A warning that the device is not intended to be used independently for diagnosis; and (iii) A summary of the clinical performance testing conducted with the device, including the study endpoints and statistical confidence intervals.

Recent Cleared Devices (1 of 1)

RecordDevice NameApplicantDecision DateDecision
DEN250014Tyto Insights for Eardrum Bulging DetectionTyto Care , Ltd.Mar 17, 2026DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...