BruxZir Opaque Coloring Liquid

K220960 · Prismatik Dentalcraft, Inc. · EIH · Jun 29, 2022 · Dental

Device Facts

Record IDK220960
Device NameBruxZir Opaque Coloring Liquid
ApplicantPrismatik Dentalcraft, Inc.
Product CodeEIH · Dental
Decision DateJun 29, 2022
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6660
Device ClassClass 2

Indications for Use

BruxZir™ Opaque Coloring Liquid is used for coloring pre-sintered zirconia structures.

Device Story

BruxZir™ Opaque Coloring Liquid consists of aqueous solutions containing transition and lanthanide metal salts used to enhance the esthetic properties of zirconia restorations. The liquid is applied to pre-sintered zirconia frameworks via dipping or using a metal-free brush. Following application, the structure is dried and sintered at temperatures exceeding 1400°C. The device is intended for use by dental technicians in a laboratory setting to fabricate dental prostheses. The coloring process allows for shade matching of the final restoration, benefiting the patient by providing esthetically pleasing dental replacements.

Clinical Evidence

No clinical data included. Substantial equivalence supported by bench testing: flexural strength and solubility per ISO 6872:2015/Amd 1:2018, visual shade evaluation, shelf life per ASTM F1980-16, packaging validation per ASTM D4169-16, and biocompatibility per ISO 10993-1 (cytotoxicity, sensitization, and oral mucosal irritation).

Technological Characteristics

Aqueous solutions of transition and lanthanide metal salts. Non-sterile. Applied via dipping or metal-free brush. Compatible with zirconia substrates. Tested per ISO 6872:2015/Amd 1:2018 (mechanical/solubility) and ISO 10993 (biocompatibility). Shelf life 2 years per ASTM F1980-16. Packaging validated per ASTM D4169-16.

Indications for Use

Indicated for coloring pre-sintered zirconia structures for dental restorations by dental technicians.

Regulatory Classification

Identification

Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue. June 29, 2022 Prismatik Dentalcraft, Inc. So Park Regulatory Affairs Manager 2144 Michelson Drive Irvine, California 92612 Re: K220960 Trade/Device Name: BruxZir Opaque Coloring Liquid Regulation Number: 21 CFR 872.6660 Regulation Name: Porcelain Powder For Clinical Use Regulatory Class: Class II Product Code: EIH Dated: March 31, 2022 Received: April 1, 2022 Dear So Park: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part {1}------------------------------------------------ 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4. Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, For Michael E. Adjodha, M.ChE. Assistant Director DHT1B: Division of Dental and ENT Devices OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT and Dental Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K220960 Device Name BruxZir™ Opaque Coloring Liquid Indications for Use (Describe) BruxZir™ Opaque Coloring Liquid is used for coloring pre-sintered zirconia structures. Type of Use (Select one or both, as applicable) X Prescription Use (Part 21 CFR 801 Subpart D) | Over-The-Counter Use (21 CFR 801 Subpart C) ### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ Image /page/3/Picture/0 description: The image contains the logo for Prismatik Dentalcraft, Inc. On the left side of the logo is a triangle with different colors. To the right of the triangle is the text "PRISMATIK DENTALCRAFT, INC." The text is in a sans-serif font and is blue. # K220960 510(k) Summary #### I. SUBMITTER Prismatik Dentalcraft, Inc. 2144 Michelson Drive. Irvine, CA 92612, USA Primary Contact Person: So Hyun Park, Regulatory Affairs Manager, MS Email: so.park@glidewelldental.com Phone: (949) 863-5479 Secondary Contact Person: Herbert Crane, VP RA/OA Email: Herbert.Crane@glidewelldental.com Phone: (949) 222-3531 Date Prepared: June 24, 2022 ### DEVICE II. Name of Device: BruxZir™ Opaque Coloring Liquid Common Name or Usual Name: Liquid for Dental Zirconia Prosthesis Classification Name: Porcelain powder for clinical use (21 CFR 872.6660) Regulatory Class: Class II Product Code: EIH ### III. PRIMARY PREDICATE DEVICE Zirkonzahn COLOUR LIQUID (K190518) ### DEVICE DESCRIPTION IV. BruxZir™ Opaque Coloring Liquid comprises a set of solutions that enhance the esthetic properties of zirconia restorations. The solution is applied to the zirconia restorations before sintering, by dipping the framework into the liquid or by using a metal-free brush. Afterwards, the structure is dried and subsequently sintered at temperatures above 1400°C. BruxZir™ Opaque Coloring Liquid is available in different colors, Opaq-Lite, Opaq-A, Opaq-C, Opaq, Opaq Plus. The devices are intended to be used solely by dental technicians for fabrication of zirconia restorations for individual dental patients. {4}------------------------------------------------ Image /page/4/Picture/0 description: The image shows the logo for PRISMATIK DENTALCRAFT, INC. The logo consists of a colorful triangle on the left and the company name on the right. The triangle is divided into several sections, each with a different color. The company name is written in blue, with "PRISMATIK" on the top line and "DENTALCRAFT, INC." on the bottom line. ### V. INDICATIONS FOR USE BruxZir™ Opaque Coloring Liquid is used for coloring pre-sintered zirconia structures. #### VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS | Technological<br>Characteristics | Subject Device<br>(TBD) | Predicate Device<br>(K190518) | Comparison | | |----------------------------------|--------------------------------------|--------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------|------------------------------------| | Design<br>Characteristics | Device Name | BruxZirTM Opaque<br>Coloring Liquid | Zirkonzahn COLOUR<br>LIQUID | N/A | | | Product Code | EIH | EIH | Same | | | Manufacturer | Prismatik Dentalcraft, Inc. | ZIRKONZAHN SRL | N/A | | | Intended Use/<br>Indications for Use | BruxZirTM Opaque<br>Coloring Liquid is used<br>for coloring pre-sintered<br>zirconia structures. | Zirkonzahn COLOUR<br>LIQUID is used for<br>coloring pre-sintered<br>zirconia structures. | Same except for the<br>device name | | | Prescription Device | Yes | Yes | Same | | | Chemical<br>Composition | Aqueous solutions of<br>transition and lanthanide<br>metal salts | Aqueous solutions of<br>transition and lanthanide<br>metal salts | Similar | | | Biocompatibility | Biocompatible | Biocompatible | Same | | | Principles of<br>Operation | Brushing or Dipping<br>Technique | Brushing or Dipping<br>Technique | Same | | | Type of Packaging<br>and Volume | Bottle; 175mL | Bottle; 20mL, 50mL,<br>100mL | Similar | | | Shade | Various; Opaq-Lite,<br>Opaq-A, Opaq-C, Opaq,<br>Opaq Plus | Various; A1-D4 | Similar | | | Sterility | Non-sterile | Non-sterile | Same | ## DETERMINATION OF SUBSTANTIAL EQUIVALENCE The subject device, BruxZir™ Opaque Coloring Liquid, is substantially equivalent in intended use, material, design principles and performance to the predicate device, Zirkonzahn COLOUR LIQUID (K190518). The intended use/indications for use for both the subject device and the predicate device are the same except for the device name. Both devices are liquids used for coloring pre-sintered zirconia restorations. The fundamental principle of operation of the subject device and the predicate device is same. The subject device and the predicate device are similar in terms of chemical composition as both devices contain transition and lanthanide metals as the major constituents. {5}------------------------------------------------ Image /page/5/Picture/0 description: The image shows the logo for Prismatik Dentalcraft, Inc. The logo consists of a colorful triangle on the left and the company name on the right. The triangle is divided into several sections, each with a different color. The company name is written in blue, with "PRISMATIK" on the top line and "DENTALCRAFT, INC." on the bottom line. The substantial equivalence comparison table above outlines and provides the similarities between the subject device, BruxZir™ Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). Both the subject device and the predicate device have similar physical/mechanical and biocompatibility properties that met the requirements of ISO 6872:2015/Amd 1:2018 and ISO 10993. And differences between the subject device and the predicate device do not raise any new concerns of safety and effectiveness. #### VII. PERFORMANCE DATA Non-clinical data submitted to demonstrate substantial equivalence include: - Mechanical testing for flexural strength and solubility ● - Vishal shade evaluation - Shelf life - Packaging validation . - Biocompatibility No clinical data is included in this submission. ### Flexural Strength Flexural strength testing was performed on the zirconia substrate treated with the subject device, BruxZir™ Opaque Coloring Liquid, per ISO 6872:2015/Amd 1:2018. The results of the testing demonstrated that the subject device does not significantly affect the mechanical property of zirconia substrate. The results of the testing were used to address questions related to substantial equivalence based on differences in device design between the subject device, BruxZir™ Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). ## Solubility Chemical solubility was tested on the worst case, which is the zirconia substrate with all 5 shades of the subject device, BruxZir"™ Opaque Coloring Liquid applied. It was concluded that the solubility is below 100 ug/cm2 limit, meeting the ISO 6872:2015/ Amd 1:2018 requirement. The result of the testing was used to address questions related to substantial equivalence based on differences in device design between the subject device, BruxZirTM Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). ### Visual Shade Evaluation The dental restorations were milled from the zirconia milling blanks with application of the subject device, BruxZir™ Opaque Coloring Liquid. Visual shade evaluations were performed on the sintered and glazed restorations by qualified reviewers against the reference shade guides. It was concluded that BruxZir"M Opaque Coloring Liquid meets shade match requirements and works as intended. The results of the testing were used to address questions related to substantial equivalence based on differences in {6}------------------------------------------------ Image /page/6/Picture/0 description: The image shows the logo for Prismatik Dentalcraft, Inc. The logo consists of a colorful triangle on the left and the company name on the right. The triangle is divided into several sections, each with a different color. The company name is written in blue, with "PRISMATIK" on the top line and "DENTALCRAFT, INC." on the bottom line. device design between the subject device, BruxZir™ Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). ## Shelf Life The accelerated aging test was performed per ASTM F1980-16 in order to establish the shelf life of the subject device, BruxZir™ Opaque Coloring Liquid. It was concluded that the shelf life of BruxZir™ Opaque Coloring Liquid is 2 years. The results of the testing were used to address questions related to substantial equivalence based on differences in shelf life between the subject device, BruxZir™ Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). ### Packaging Validation Packaging validation was performed on the subject device, BruxZir1M Opaque Coloring Liquid. Per ASTM D4169-16, the shipping unit was tested for manual handling drops, vehicle stacking, loose load vibration, low pressure hazard, vehicle vibration and concentrated impact. Following distribution simulation testing, the packaging contents were visually inspected for signs of damages, or leaks. Visual examination of the parts did not reveal any damage of the packaged contents and any leaks of the coloring liquids and revealed that the seal of the bottles was intact. The results of the testing were used to address questions related to substantial equivalence based on differences in packaging configuration between the subject device, BruxZir™ Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). ### Biocompatibility The subject device, BruxZir™ Opaque Coloring Liquid, was tested in accordance with ISO 10993-1. Per the biological evaluation, BruxZir™ Opaque Coloring Liquid was tested for Cytotoxicity (ISO 10993-5:2009), Sensitization (ISO 10993-10:2010) and Oral Mucosal Irritation (ISO 10993-10:2010) to meet the biocompatibility requirements. Based on the biocompatibility testing results, it was determined that there is no biocompatibility concern for the subject device. The results of the testing were used to address questions related to substantial equivalence based on differences in chemical composition between the subject device, BruxZir"M Opaque Coloring Liquid, and the predicate device, Zirkonzahn COLOUR LIQUID (K190518). ### VIII. CONCLUSION Based on the technological characteristics and non-clinical test data included in this submission, the subject device, BruxZir"M Opaque Coloring Liquid, has been shown to be substantially equivalent to the primary predicate device, Zirkonzahn COLOUR LIQUID (K190518).
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...