TIGER 500 SERIES HIGH SPEED HANDPIECES AND ATTACHMENTS

K102517 · Thunder Tiger Corp. · EFB · Apr 27, 2011 · Dental

Device Facts

Record IDK102517
Device NameTIGER 500 SERIES HIGH SPEED HANDPIECES AND ATTACHMENTS
ApplicantThunder Tiger Corp.
Product CodeEFB · Dental
Decision DateApr 27, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.4200
Device ClassClass 1
AttributesTherapeutic

Intended Use

Tiger 500 Series High Speed Handpieces and Attachments are intended for removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth.

Device Story

Air-powered dental handpieces; reusable; ergonomically shaped; available with or without fiber optic light system. Used by dentists/dental professionals in clinical settings for tooth preparation and restoration procedures. Connects to various manufacturer couplings (TTBIO, KaVo, NSK Mach, Sirona, Star). Supplied non-sterile; requires sterilization before use. Provides mechanical power to rotary dental burs for cutting/polishing tooth structure; enables precise removal of carious material and finishing of restorations. Benefits patient by facilitating restorative dental procedures.

Clinical Evidence

Bench testing only. Performance and safety verified through conformity with ISO 7785-1 (High-speed air turbine handpieces). No clinical data provided.

Technological Characteristics

Air-powered turbine handpiece; reusable; fiber optic light option. Complies with ISO 7785-1:1997 for high-speed air turbine handpieces. Manufactured under ISO 13485:2003 quality management system. Compatible with multiple industry-standard couplings. Non-sterile, autoclavable.

Indications for Use

Indicated for dental patients requiring removal of carious material, reduction of hard tooth structure, cavity preparation, finishing of preparations and restorations, and tooth polishing. Restricted to use by licensed professionals.

Regulatory Classification

Identification

A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo for Thunder Tiger. The logo consists of a circle with an airplane inside of it on the left. To the right of the circle is the text "Thunder Tiger" written in a stylized font, with the word "Thunder" on top of the word "Tiger". THUNDER TIGER CORP. APR 2 7 2011 NO.7, 6th ROAD INDUSTRY PARK, TAICHUNG. TAIWAN. R.O.C. 40755 TEL : 886-4-23591616 FAX : 886-4-23591902 E-mail: tt@thundertiger.com http://www.thundertiger.com ### K10 2517 510(K) SUMMARY # Tiger 500 Series High Speed Handpieces and Attachments 1. Date Summary Prepared: December 20,2010 2. Submitter Information 510(k) Owner: THUNDER TIGER CORP. No.7, 6th Road, Industry Park, Taichung, 40755 Taiwan, ROC Contact Person: Jo S.C. Lee/QA Engineer jo@thundertiger.com 3. Device Name -Trade-Name :- Tiger-500 Series-High-Speed-Handpieces-and-Attachments- Common Name: Dental Handpiece Classification Name: Handpiece, Air-Powered, Dental (21 CFR 872.4200, Product Code EFB) 4. Predicate Device: Dental Air-Powered Handpiece, models TIGER 300T, TIGER 300K, TIGER 300W, TIGER 300B, TIGER 300N (K062812) SUPERtorque High-Speed Handpieces (K073478) Tradition high speed Handpiece (K863677) Rapidd high speed Handpiece (K003518) 5. Device Description: The Tiger 500 series High Speed Handpieces and Attachments are similar to other high-speed dental handpieces currently on the US dental market in design, function, and intended use. The devices are air-powered handpieces that are reusable and ergonomically shaped, and are provided both with and without a fiber optic light system. The devices are supplied non-sterile, but must be sterilized before use, as with the predicate device. It will be packaged as a single-use bag. Several models could be connected to couplings of manufacturers including TTBIO, KaVo, NSK Mach, Sirona, and Star. According to IS07785-1:1997, Dental Handpiece-- Part 1: High-speed air turbine handpieces; and IS013485:2003, Medical Device Quality Management System to complete the device design steps. {1}------------------------------------------------ # K102517 Image /page/1/Picture/1 description: The image shows the logo for Thunder Tiger. The logo consists of a circle with an airplane inside of it on the left side. To the right of the circle, the words "Thunder Tiger" are written in a bold, sans-serif font, with the word "Thunder" on top of the word "Tiger". THUNDER TIGER CORP. NO.7. 6th ROAD INDUSTRY PARK, TAICHUNG, TAIWAN, R.O.C. 40755 TEL : 886-4-23591616 FAX : 886-4-23591902 E-mail: tt@thundertiger.com http://www.thundertiger.com - Intended Use: 6. Tiger 500 Series High Speed Handpieces are intended for removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth. CAUTION: U.S. Federal law restricts the use of this device to licensed professionals. 7. Technological Characteristics: The functions of Tiger 500 series High Speed Handpieces and Attachments were verified according to ISO7785-1. The substances of Tiger 500 series High Speed Handpieces are same as the predicate device in terms of its intended use, operating principles and functions. - 8. Non-Clinical Performance/Safety Data: The performance and safety of the Tiger 500 series High Speed Handpieces and Attachments are based upon conformity with applicable aspects of ISO 7785-1. Bench testing results demonstrate substantially equivalence. Therefore, we conclude that the both safe and effective for its intended use. | Substantial Equivalence Table | | |--------------------------------------------------|-------------------------| | TECHNOLOGICAL CHARACTERISTIC | COMPARISON TO PREDICATE | | Intended use | Identical | | Indications for use | Identical | | Target population | Identical | | Anatomical sites | Identical | | Energy used and/or delivered | Similar | | Human factors | Similar | | Design | Similar | | Performance | Similar | | Standards met | Identical | | Materials | Similar | | Biocompatibility | Identical | | Compatibility with environment and other devices | Identical | | Sterility | Identical | | Mechanical safety | Identical | | Chemical Safety | Identical | | Thermal safety | Identical | | Radiation safety | Identical | 9. Substantial Equivalence {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for Thunder Tiger. The logo consists of a circle with an airplane in the middle, and the words "Thunder Tiger" written in a stylized font to the right of the circle. The words "Thunder" and "Tiger" are stacked on top of each other, with a line above and below each word. THUNDER TIGER CORP. NO.7, 6th ROAD INDUSTRY PARK, TAICHUNG, TAIWAN, R.O.C. 40755 FAX : 886-4-23591902 TEL : 886-4-23591616 E-mail: tt@thundertiger.com http://www.thundertiger.com ### 10. Conclusion: The above descriptions coincide with the substantial equivalence made by Dental Air-Powered Handpiece, models TIGER 300T, TIGER 300K, TIGER 300W, TIGER 300B, TIGER 300N (K062812), SUPERtorque High-Speed Handpieces (K073478), Tradition high speed Handpiece (K863677) and Rapidd high speed Handpiece (K003518). They are same as the predicate device in terms of its intended use, operating principles and functions. Therefore, it can be seen that Tiger 500 series High Speed Handpieces are both safe and effective for their intended use. {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized eagle or bird-like symbol with three curved lines representing its wings or body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the symbol. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 Mr. Jo S.C. Lee Ouality Assurance Engineer Thunder Tiger Corporation No. 7, 6th Road Industry Park Taichung China (Taiwan) R.O.C. 40755 APR 2 7 2011 Re: K102517 Trade/Device Name: Tiger 500 Series High Speed Handpieces and Attachments Regulation Number: 21 CFR 872.4200 Regulation Name: Dental Handpiece Accessories Regulatory Class: I Product Code: EFB Dated: April 19, 2011 Received: April 21, 2011 Dear Mr. Lee: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {4}------------------------------------------------ Page 2- Mr. Lee Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting . (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm l 15809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/ default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely vours. Nh for Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology. General Hospital. Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ Image /page/5/Picture/0 description: The image shows the logo for Thunder Tiger. The logo consists of a circle with an airplane inside of it on the left, and the words "Thunder Tiger" on the right. The word "Thunder" is on top of the word "Tiger", and there is a line above the word "Tiger". 、 THUNDER TIGER CORP. NO.7, 6th ROAD INDUSTRY PARK, TAICHUNG, TAIWAN, R.O.C. 40755 TEL : 886-4-23591616 FAX : 886-4-23591902 E-mail: tt@thundertiger.com http://www.thundertiger.com ## Indications for Use 510(K) Number (If Known): ____________________________________________________________________________________________________________________________________________________ Device Name: Tiger 500 Series High Speed Handpieces and Attachments Indications for Use: Tiger 500 Series High Speed Handpieces and Attachments are intended for removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth. Over-The-Counter Use_ AND/OR Prescription Use_ X (21 CFR 801 Subpart C) (Part 21 CFR 801 Subpart D) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) | Concurrence of CDRH Office of Device Evaluation (ODE) | | |-----------------------------------------------------------------------------------|---------| | BSBetz DDS for Dr Susan Renner | | | (Division Sign-Off) | | | Division of Anesthesiology, General Hospital<br>Infection Control, Dental Devices | | | 510(k) Number: | K102517 | age 4-1
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...