The Valplast Corporation Yamahachi Teeth are prefabricated, preformed plastic teeth that are intended for use as teeth in removable dentures.
Device Story
Yamahachi Teeth are prefabricated anterior and posterior plastic teeth for use in removable full or partial dentures. Used by dental professionals (dentists, technicians) in clinical or laboratory settings. Constructed from synthetic polymers (polymethylmethacrylate, polymethylmethacrylate-SiO2, and composite resin urethane dimethacrylate-polymethylmethacrylate-SiO2). Teeth are integrated into denture-base resins to restore patient dentition. Benefits include restoration of oral function and aesthetics through various available sizes, shapes, and shades.
Clinical Evidence
Bench testing only. Compliance demonstrated with EN ISO 3336:1997 (synthetic polymer teeth), EN ISO 7405:1997 (biocompatibility), EN ISO 1567:1995 (denture base polymers), EN ISO 3950:1997 (designation system), and EN ISO 7491:2000 (color stability).
Technological Characteristics
Materials: polymethylmethacrylate, polymethylmethacrylate-SiO2, composite resin urethane dimethacrylate-polymethylmethacrylate-SiO2. Form factor: preformed anterior/posterior teeth. Standards: EN ISO 3336:1997, EN ISO 7405:1997, EN ISO 1567:1995, EN ISO 3950:1997, EN ISO 7491:2000.
Indications for Use
Indicated for use as artificial teeth in removable full or partial dentures for patients requiring dental prosthetics.
Regulatory Classification
Identification
A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl methacrylate, that is intended for use as a tooth in a denture.
Special Controls
*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9.
{0}------------------------------------------------
# K060507 510(k) Summary for Valplast Yamahachi Teeth
#### 1. SPONSOR APR 7 2006
Valplast International Corp. 34-30 31st Street Long Island, NY 11106
Contact Person: Peter Nagy Telephone: 1-718-361-7440
Date Prepared: February 23, 2006
### 2. DEVICE NAME
Proprietary Name: Yamahachi Teeth Common/Usual Name: Dentures Classification Name: Plastic preformed teeth for dentures
### 3. PREDICATE DEVICES
Heraeus Kulzer, Inc., Artic Plastic Teeth Dentures subject of K033628
Merz Dental GmbH Artegral and Polystar Selection Preformed Plastic Teeth subject of K030588
#### 4. DEVICE DESCRIPTION
The Yamahachi Teeth are anterior and posterior teeth that are intended to be used in removable dentures only. They are made up of three synthetic polymers including polymethlymethacrylate, polymethylmethacrylate-SiO2, and a composite resin urethane dimethacrylate-polymethylmethacrylate - SiO2. The Yamahachi Teeth are used in conjunction with a denture-base resin for construction of removable full and partial dentures. The teeth are intended to be used by dental professionals such as dentists and dental technicians. The Yamahachi line of teeth include various sizes, shapes, and shades of anterior and posterior preformed plastic teeth
{1}------------------------------------------------
### 5. INTENDED USE
The Valplast Corporation Yamahachi Teeth are prefabricated, preformed plastic teeth that are intended for use as teeth in removable dentures.
### TECHNOLOGICAL CHARACTERISTICS AND SUBSTANTIAL EQUIVALENCE 6.
The proposed Yamahachi teeth are essentially identical to the predicate devices in that they are all made from methylmethacrylate or a derivative of methylmethacrylate. The proposed and predicate devices are offered in various sizes, shapes, and colors. Like the predicate devices, the Yamahachi Teeth are artificial resin teeth that are compatible with all denture base resins.
### 7. PERFORMANCE TESTING
Extensive testing has been performed on the Yamahachi Teeth to demonstrate compliance with EN ISO 3336:1997 Dentistry; Synthetic polymer teeth; EN ISO 7405:1997 Dentistry; Preclinical evaluation of biocompatibility of medical devices used in dentistry, Test methods for dental materials; EN ISO 1567:1995 Denture Base Polymers; EN ISO 3950:1997 Dentistry-Designation system for teeth and areas of the oral cavity; and EN ISO 7491:2000 Dental Materials-Determination of color stability of dental polymeric materials.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image is a black and white circular seal. The seal features the logo of the U.S. Department of Health and Human Services. The logo includes a stylized depiction of an eagle or bird-like figure with three curved lines representing its wings or body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the top half of the circle.
Public Health Service
7 2006 APR
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Valplast International Corporation C/O Ms. Mary McNamara-Cullinane, RAC Senior Regulatory Consultant Medical Device Consultants, Incorporated 49 Plain Street North Attleboro, Massachusetts 02760
Re: K060507
Trade/Device Name: Yamahachi Teeth Regulation Number: 21 CFR 872.3590 Regulation Name: Preformed Plastic Denture Tooth Regulatory Class: II Product Code: ELM Dated: February 23, 2006 Received: February 28, 2006
Dear Ms. McNamara-Cullinane:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{3}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
X.ute Y. Michau OMD
Chiu S. Lin, PhD Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
### Indications for Use
510(k) Number (if known): K060507
Device Name: Valplast Yamahachi Teeth
Indications for Use: The Valplast International Corporation Yamahachi Teeth are prefabricated, preformed plastic teeth that are intended for use as teeth in removable dentures.
Prescription Use X (Part 21 CFR 801 Subpart D)
## AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Suver Thorpe
Bay. General H
Texas
K060507
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.