The intended use of PerioGlas is to provide a safe, biocompatible synthetic bone graft material for use in oral, dental intraosseous, and craniofacial defects. It is used alone in a manner comparable to autogenous bone graft chips or allograft bone particulate (Demineralized Freeze Dried Bone) or may be mixed with either (typically 1:1 ratio v/v) as a bone graft extender. Typical uses include: - Periodontal/Infrabony defects - Ridge Augmentation (sinusotomy, osteotomy, cystectomy) - Extraction sites (ridge maintenance/augmentation, implant preparation/ placement) - Sinus lifts - Cystic cavities - Cranio-facial augmentation For larger defects, a mixture of PerioGlas® with an equal volume of allograft or autograft bone and bone marrow may improve new bone formation.
Device Story
PerioGlas is a synthetic, resorbable, osteoconductive bone void filler composed of 45S5 bioactive glass particulate. Supplied sterile; mixed at point-of-care with sterile water, saline, patient blood/marrow, or autogenous/allograft bone to form a wet paste. Applied by clinicians into bony defects during oral, dental, or craniofacial surgical procedures. Acts as a non-structural scaffold; progressively resorbed and replaced by new bone tissue. Device exhibits osteostimulative properties, promoting osteoblast proliferation and differentiation. Used by surgeons/dentists to facilitate bone regeneration in defects; benefits patient by providing a biocompatible alternative to autogenous or allograft bone.
Clinical Evidence
No human clinical trials presented. Evidence consists of in vivo study data supporting superior rate of osteoconduction and bone formation compared to hydroxyapatite devices, and in vitro osteoblast cell culture studies demonstrating osteostimulative effects (increased DNA content, elevated osteocalcin and alkaline phosphatase levels).
Technological Characteristics
Single-phase bioactive glass (45S5 Bioglass) particulate. Osteoconductive, synthetic, inorganic, biocompatible material. Non-structural scaffold. Supplied sterile. No software or electronic components.
Indications for Use
Indicated for packing into bony voids or gaps to fill/augment oral, dental intraosseous, and craniofacial defects, including periodontal/infrabony defects, alveolar ridge augmentation, dental extraction sites, sinus lifts, cystic defects, and craniofacial augmentation. No specific age or gender contraindications listed beyond standard surgical/anesthesia risks.
Regulatory Classification
Identification
Bone grafting material is a material such as hydroxyapatite, tricalcium phosphate, polylactic and polyglycolic acids, or collagen, that is intended to fill, augment, or reconstruct periodontal or bony defects of the oral and maxillofacial region.
Special Controls
*Classification.* (1) Class II (special controls) for bone grafting materials that do not contain a drug that is a therapeutic biologic. The special control is FDA's “Class II Special Controls Guidance Document: Dental Bone Grafting Material Devices.” (See § 872.1(e) for the availability of this guidance document.)(2) Class III (premarket approval) for bone grafting materials that contain a drug that is a therapeutic biologic. Bone grafting materials that contain a drug that is a therapeutic biologic, such as biological response modifiers, require premarket approval.
(c)
*Date premarket approval application (PMA) or notice of product development protocol (PDP) is required.* Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.
NovaBone - Resorbable Bone Graft Substitute (K052494, K021336)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for NOVABONE synthetic bone graft products. The logo is in black and white, with the word "NOVABONE" in large, bold letters. A star-like shape is in the middle of the word. Below the word "NOVABONE" is the phrase "SYNTHETIC BONE GRAFT PRODUCTS" in smaller letters.
K05387
FEB 1 4 2006
12/01/05
# 510(k) Summary PerioGlas - Bone Graft Particulate
#### Submitter Information: 1.
| Name: | NovaBone Products, LLC |
|------------|----------------------------------------------------|
| Address: | 13709 Progress Boulevard, #33<br>Alachua, FL 32615 |
| Telephone: | (386) 462-7660 |
| Facsimile: | (386) 418-1636 |
| Contact: | David M. Gaisser |
#### 2. Name of Device:
| Trade Name: | PerioGlas – Bone Graft Particulate |
|----------------------|------------------------------------------------------------------------------|
| Common Name: | Osteoconductive Bone Void Filler<br>Synthetic Resorbable Bone Graft Material |
| Classification Name: | Endosseous Implant for Bone Filling and/or Augmentation |
#### 3. Legally Marketed Predicate Device:
| Predicate #1: | PerioGlas - Synthetic Bone Graft Particulate<br>[K040278, K992416, K962492, K930115]<br>(Also named as NovaBone per Special 510(k) K000149) |
|---------------|---------------------------------------------------------------------------------------------------------------------------------------------|
| Predicate #2: | NovaBone -- Resorbable Bone Graft Substitute<br>[K052494, K021336] |
#### Device Description 4.
PerioGlas is a one-component resorbable bone void filler composed of a synthetic calcium phospho-silicate (Bioglass) particulate designed specifically for its absorbability and osteoconductive nature. The device is intended for dental intraosseous, oral, and cranio-/maxillofacial bony defects. It is supplied sterile. At time of use, the device is mixed with sterile water, saline, the patient's own blood or marrow, or with autogenous or allograft bone to form a wet sandy paste that is applied to the defect. PerioGlas is progressively resorbed and replaced by new bone tissue during the healing process.
#### ડ. Intended Use
PerioGlas is indicated to be packed into bony voids or gaps to fill and/or augment oral, dental intraosseous, and craniofacial defects. These defects may include: periodontal/infrabony defects; alveolar ridge augmentation (sinusotomy, osteotomy, cystectomy); dental extraction sites (ridge maintenance, implant
NOVABONF PRODUCTS. LLC
13709 PROGRESS BLVD., #33 · ALACHUA. FL 32615 · (386) 462-7660 · FAX (386) 418-1636
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the text "K03387" in a handwritten style, with a line drawn underneath it. Below the line, the word "Confidential" is printed in a smaller, more formal font. The text suggests that the document or information is sensitive and should be kept private.
preparation/placement); sinus lifts; cystic defects; craniofacial augmentation. PerioGlas may be used alone in a manner comparable to autogenous bone graft chips or allograft bone particulate (demineralized freeze dried bone), or it may be mixed with either as a bone graft extender.
### Technological Characteristics 6.
The device is designed as an osteoconductive space-filling particulate device to be gently packed into defect sites and used as a non-structural scaffold for the body's natural healing and bone regeneration process. The device acts as a particulate, synthetic, inorganic, biocompatible and osteoconductive material.
PerioGlas is a single-phase bioactive glass (45S5 Bioglass) particulate device. No changes to the device or its indications have been made with this submission. The purpose of this premarket notification is to expand the product claims to cover the claim of the device being osteostimulative. After implantation, surface reactions result in the absorption of the device material and concurrent new bone tissue formation. These surface reactions result in an osteostimulative affect, defined as the stimulation of osteoblast proliferation and differentiation during in vitro osteoblast cell culture studies as evidenced by increased DNA content and elevated osteocalcin and alkaline phosphatase levels.
#### 7. Complications
No modifications have been made to the PerioGlas device. Possible complications are the same as to be expected of autogenous bone grafting procedures. These may include: superficial wound infection, deep wound infection, deep wound infection with osteomyelitis, delayed union, loss of reduction, failure of fusion, loss of bone graft, graft protrusion and / or dislodgement, and general complications that may arise from anesthesia and / or surgery. Complications specific to oral/dental use are those as may be typically observed for similar bone grafting procedures and may include: tooth sensitivity, gingival recession, flap sloughing, resorption or ankylosis of the treated root, abscess formation
#### 8. Conclusion
PerioGlas functions as a bone void filler for non-structural osseous defects. In vivo study data were presented supporting a superior rate of osteconduction and bone formation at early post-implantation periods compared to hydroxyapatite devices. In vitro cell culture data were presented to demonstrate and define the osteostimulative nature of the PerioGlas device. The addition of this claim does not modify the characteristics of the device, which has not been modified for this submission.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the seal of the Department of Health and Human Services (HHS). The seal features the department's name in a circular arrangement around a symbol. The symbol consists of a stylized caduceus, which is a traditional symbol of medicine, with three figures representing health, services, and human needs.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
FFB 1 4 2006
Mr. David M. Gaisser VP Operations Novabone Products, LLC 13709 Progress Boulevard, #33 Alachua, Florida 32615
Re: K053387
Trade/Device Name: Perioglas Bone Graft Particulate Regulation Number: 21 CFR 872.3930 Regulation Name: Tricalcium phosphate granules for dental bone repair Regulatory Class: II Product Code: LYC Dated: December 1, 2005 Received: December 9, 2005
Dear Mr. Gaisser:
We have reviewed your Section 510(k) premarket notification of intent to market the device we mayors we and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in muronomons for acce prior to May 28, 1976, the enactment date of the Medical Device mendments, or to devices that have been reclassified in accordance with the provisions of Amendinens, or to act 1000 and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general approvisions of the Act. The general controls provisions of the Act include controls providers or a registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting (1 mr.), it and be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{3}------------------------------------------------
## Page 2 – Mr. David M. Gaisser
Please be advised that FDA's issuance of a substantial equivalence determination does not Please be auvised that I DA 3 issualled on that your device complies with other requirements mean that FDA has made a decemmanen until Joan administered by other Federal agencies. of the Act or ally rederal statutes and regulations, but not limited to: registration You must comply with an the Fee s requirement) and 801); good manufacturing practices
and listing (21 CFR Part 807); labeling (21 CFR Part 801); gDD manufacturing practice and listing (21 CFR Part 807), laboling (21 creating (21 CFR Part 820); and if requirents as set form in the quality of seatly of stone (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 5 10(k) This letter will anow you to begin mailering your antial equivalence of your device to a premits of the results in the PDF intellige of classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), If you desire specific advice for your de at (240) 276-0115. Also, please note the regulation prease contact the Office or Compe to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Inay obtain other general international and Consumer Assistance at its toll-free Division of 01 01 01 (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Synette y. Michael Davis
Chia Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Confidential
510(k) Premarket Notification NovaBone Products, LLC PerioGlas - Bone Graft Particulate
ticulate
K03387
STATEMENT OF INDICATIONS FOR USE
510(k) Number (if known): ______________________
Device Name: _________________________________________________________________________________________________________________________________________________________________
Indications For Use:
The intended use of PerioGlas is to provide a safe, biocompatible synthetic bone graft material for use in oral, dental intraosseous, and craniofacial defects. It is used alone in a manner comparable to autogenous bone graft chips or allograft bone particulate (Demineralized Freeze Dried Bone) or may be mixed with either (typically 1:1 ratio v/v) as a bone graft extender. Typical uses include:
- · Periodontal/Infrabony defects
- · Ridge Augmentation (sinusotomy, osteotomy, cystectomy)
- · Extraction sites (ridge maintenance/augmentation, implant preparation/ placement)
- Sinus lifts
- · Cystic cavities
- · Cranio-facial augmentation
For larger defects, a mixture of PerioGlas® with an equal volume of allograft or autograft bone and bone marrow may improve new bone formation.
Prescription Use_XX_
OR (Per 21 CFR 801.109) Over-The-Counter Use
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Siner Ruang
physiology, General Hospital,
Infection Control, Dental Devices
Number: K053387
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.