The Heart Sync Pediatric Radiotranslucent Multifunction Electrodes are indicated for use in external pacing, defibrillation and monitoring applications as a non-sterile, disposable device for single patient use only. The electrodes provide the conductive interface between the defibrillator and/or the external transcutaneous (noninvasive) cardiac pacemaker and the patient's skin. The electrode is intended for use on pediatric patients whose weight is less than 25 kg. When a patient requires defibrillation, cardioversion or external pacing, these electrodes will be applied to the patient and connected to the instrument. This device is intended for use on defibrillators whose output is classified as low power (360 joule maximum). Compatible with Medtronic Physio Control, Zoll, Hewlett-Packard, Philips Medical, and Welch-Allyn models of monophasic and bi-phasic defibrillators, external pacemakers.
Device Story
Heart Sync Pediatric Radiotranslucent Multifunction Electrodes serve as conductive interface between patient skin and external defibrillators/pacemakers. Device consists of disposable, self-adhesive pads with polymer adhesive gel for uniform current distribution. Used in hospitals and paramedic settings for defibrillation, pacing, cardioversion, and monitoring. Radiotranslucent design allows pads to remain on patient during imaging procedures. Clinicians apply electrodes to patient and connect to compatible monophasic or bi-phasic defibrillator/pacemaker units. Facilitates effective energy delivery for cardiac therapy.
Clinical Evidence
No clinical data. Substantial equivalence based on design, intended use, and adherence to performance standards (21 CFR 898.12; ANSI/AAMI DF-39).
Technological Characteristics
Non-sterile, disposable, self-adhesive electrodes. Features polymer adhesive gel for current distribution. Radiotranslucent construction. Compatible with monophasic and bi-phasic defibrillators/pacemakers. Meets 21 CFR 898.12 and ANSI/AAMI DF-39 standards.
Indications for Use
Indicated for pediatric patients weighing less than 25 kg requiring external pacing, defibrillation, cardioversion, or monitoring. Compatible with low-power (max 360J) monophasic and bi-phasic defibrillators and external pacemakers.
Regulatory Classification
Identification
Low-energy DC-defibrillator: A device that delivers into a 50 ohm test load an electrical shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart or to terminate other cardiac arrhythmias. This generic type of device includes low energy defibrillators with a maximum electrical output of less than 360 joules of energy that are used in pediatric defibrillation or in cardiac surgery. The device may either synchronize the shock with the proper phase of the electrocardiogram or may operate asynchronously. The device delivers the electrical shock through paddles placed either directly across the heart or on the surface of the body. High-energy DC-defibrillator: A device that delivers into a 50 ohm test load an electrical shock of greater than 360 joules of energy used for defibrillating the atria or ventricles of the heart or to terminate other cardiac arrhythmias. The device may either synchronize the shock with the proper phase of the electrocardiogram or may operate asynchronously. The device delivers the electrical shock through paddles placed either directly across the heart or on the surface of the body.
K014209 — PADPRO MODEL 2001, 2001-S, 2001-C, 2001-EPS · Padpro, LLC · Jan 18, 2002
K020203 — PADPRO MODEL #2516 · Padpro, LLC · May 8, 2002
K020288 — PADPRO, MODEL 2603 · Padpro, LLC · Feb 27, 2002
K081371 — SKINTACT PEDIATRIC MULTIFUNCTION ELECTRODES WITH DH03 GEL · Leonhard Lang GmbH · Sep 24, 2008
K032421 — AMBU PEDIATRIC MULTI-FUNCTION DEFIBRILLATION ELECTRODE · Ambu, Inc. · Feb 27, 2004
Submission Summary (Full Text)
{0}------------------------------------------------
SEP 2 4 2008
## EXHIBIT 2
Heart Sync Inc. 5643 Plymouth Rd. Ann Arbor, Mi 48105 Phone: 800-828-4681 Fax: 734-213-5640 Contact: Stephen Shulman, President May 22, 2008 510(k) Summarv
- 1. Identification of the Device: Proprietary-Trade Name: "Heart Sync" Pediatric Radiotranslucent Multifunction Electrodes, model # Pediatric-100.
Classification Name: DC-defibrillator Common/Usual Name: Defibrillator Electrode
- 2. Equivalent legally marketed devices: This is identical in function to the Pad Pro K020288.
- Indications for Use: The Heart Sync Pediatric Radiotranslucent Multifunction Electrodes 3. are indicated for use in external pacing, defibrillation and monitoring applications as a non-sterile, disposable device for single patient use only. The electrodes provide the conductive interface between the defibrillator and/or the external transcutaneous (noninvasive) cardiac pacemaker and the patient's skin. The electrode is intended for use on pediatric patients whose weight is less than 25 kg. When a patient requires defibrillation, cardioversion or external pacing, these electrodes will be applied to the patient and connected to the instrument. This device is intended for use on defibrillators whose output is classified as low power (360 joule maximum).
Compatible with Medtronic Physio Control, Zoll, Hewlett-Packard, Philips Medical, and Welch-Allyn models of monophasic and bi-phasic defibrillators, external pacemakers.
- 4. Description of the Devices: Features & Benefits:
The electrodes are multifunction because they can be used for defibrillation, pacing, cardioversion, and monitoring. Heart Sync electrodes can be used on Physio Control, Zoll, Hewlett-Packard, Philips and Welch-Allyn makes and models of monophasic and bi-phasic defibrillator. Radiotranslucent "One Pad System" enables the pads to stay with the patient as they move through departments. Heart Sync has an electrode for any clinical need or patient situation. Heart Sync can provide onsite conversion of current cables to accept the Heart Sync electrodes. The polymer adhesive gel provides contact for uniform current distribution and more effective defibrillation and pacing.
{1}------------------------------------------------
Model differentiation:
| Model | Feature/difference |
|-------------------------|----------------------------------|
| Pediatric PEDIATRIC-100 | Pad Conductive Area 35.3. sq cm. |
| Predicate K020288 | Pad Conductive Area 36.9 sq cm |
## 5. Safety and Effectiveness, comparison to predicate device:
| Comparison Areas | PadPro K 020288 | "Heart Sync"<br>Pediatric<br>PEDIATRIC-100 |
|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|
| Indications for use | For use as disposable electrodes for<br>Semi-automatic and manual external<br>defibrillators for monitoring, pacing,<br>cardioversion, and defibrillation | SAME |
| Where used | Hospitals and Paramedic situations | SAME |
| Basic features | Radiotranslucent, non sterile, latex<br>free, single patient use, self<br>adhesive, in sealed foil pouch. | SAME |
| Standard met | 21CFR 898.12 Performance standard;<br>ANSI/AAMI DF-39 (3.3.19)<br>standard, self adhesive electrodes for<br>monitoring and defibrillation | SAME |
- 6. Conclusion In all respects, the Heart Sync System Defibrillator Electrodes are substantially equivalent to other electrodes that are legally marketed for this purpose. The device meets the standards referenced above.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features a stylized eagle with its wings spread, symbolizing protection and service. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the eagle, indicating the department's name and national affiliation.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
SEP 24 L.
Heart Sync LLC c/o Mr. Stephen Shulman Managing Partner 5643 Plymouth Road Ann Arbor, MI 48105
Rc: K081442
Trade/Device Name: "Heart Sync" Pediatric Radiotranslucent Multifunction Electrodes Regulation Number: 21 CFR 870.5300 Regulation Name: DC-defibrillator (including paddles) Regulatory Class: Class II Product Code: LDD Dated: September 15, 2008 Received: September 16, 2008
Dear Mr. Shulman:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality
{3}------------------------------------------------
Page 2 -- Mr. Stephen Shulman
systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-3464. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometrics' (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Qamee
Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
j) Indications for Use
510(k) Number
Device Name: "Heart Sync" Pediatric Radiotranslucent Multifunction Electrodes
The Heart Sync Pediatric Radiotranslucent Multifunction Electrodes are indicated for use in external pacing, defibrillation and monitoring applications as a non-sterile, disposable device for single patient use only. The electrodes provide the conductive interface between the defibrillator and/or the external transcutaneous (noninvasive) cardiac pacemaker and the patient's skin. The electrode is intended for use on pediatric patients whose weight is less than 25 kg. When a patient requires defibrillation, cardioversion or external pacing, these electrodes will be applied to the patient and connected to the instrument. This device is intended for use on defibrillators whose output is classified as low power (360 joule maximum).
Compatible with Medtronic Physio Control, Zoll, Hewlett-Packard, Philips Medical, and Welch-Allyn models of monophasic and bi-phasic defibrillators, external pacemakers.
Prescription Use X
OR
Over the Counter Use
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Per 21 CFR 801.109)
Qamel
ion Sianision of Cardiovascular Devices
KOS1442 510(k) Number.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.