FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
CFR Sub-Part
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart C—Cardiovascular Monitoring Devices
CFR Sub-Part
Subpart D—Cardiovascular Prosthetic Devices
CFR Sub-Part
DST
Clip, Vena-Cava
2
Product Code
DSW
Bag, Polymeric Mesh, Pacemaker
1
Product Code
DSY
Prosthesis, Vascular Graft, Of 6mm And Greater Diameter
2
Product Code
DSZ
Pacemaker Battery
3
Product Code
DTA
Tester, Pacemaker Electrode Function
2
Product Code
DTB
Permanent Pacemaker Electrode
3
Product Code
DTC
Analyzer, Pacemaker Generator Function
2
Product Code
DTD
Pacemaker Lead Adaptor
2
Product Code
DTE
Pulse-Generator, Pacemaker, External
2
Product Code
DTF
Tools, Pacemaker Service
1
Product Code
DTG
Magnet, Test, Pacemaker
1
Product Code
DTI
Sizer, Heart-Valve, Prosthesis
1
Product Code
DTJ
Holder, Heart-Valve, Prosthesis
1
Product Code
DTK
Filter, Intravascular, Cardiovascular
2
Product Code
DSP
System, Balloon, Intra-Aortic And Control
2
Product Code
DSR
Stimulator, Carotid Sinus Nerve
3
Product Code
DSS
Clip, Vascular
2
Product Code
DXY
Implantable Pacemaker Pulse-Generator
3
Product Code
K
99
3434
PIKOS 01, PIKOS E01, PIKOS 01-B, PIKOS E01-B, PIKOS 01-A, PIKOS E01-A
3
Cleared 510(K)
K
97
0072
OPUS S MODEL 4121 AND 4124 PACEMAKERS
3
Cleared 510(K)
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
APPR
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
APPR
PMA Approval
K
94
5627
PIKOS LP 01, PIKOS LP E01
3
Cleared 510(K)
K
95
3866
MINIX 834M & MINIX ST 8331M PULSE GENERATORS (MODIFICATION)
3
Cleared 510(K)
K
95
4092
ALTERNATE STERLIZATION PROCESS & MODIFIED DF-1 LEAD CONNECTOR (MODIFICATION)
3
Cleared 510(K)
K
95
3417
MINIFLEX MODEL 340, 341, AND 342 PULSE GENERATORS
3
Cleared 510(K)
K
95
2328
NANOS, PIKOS 01/E01, 01-A, E01-B, LP 01/LP E01
3
Cleared 510(K)
K
95
2364
OPUS PACEMAKERS (MODELS 4001, 4003, 4004, 4023, 4024)
3
Cleared 510(K)
P
95
0037
Siello T/JT, Solia T/JT, Siello S, Solia S, Evia DR, Evia DR-T, Evia SR, Entovis DR, Entovis DR-T, Entovis SR, Entovis S
3
PMA Approval
P
88
0086
Endurity Core, Endurity, Zenex, Zenus
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
95
0037
Ilesto 7 VR-T DX, Ilesto 7 VR-T, Ilesto 5 VR-T DX, Ilesto 5 VR-T, Iforia 7 VR-T DX, Ilesto 7 VR-T (DF4), Ilesto 5 VR-T (
3
PMA Approval
P
95
0029
Smart Monitor, Smart Spot, SmartView Monitor, SmartView HotSpot
3
PMA Approval
P
95
0037
Evia SR-T, Evia SR, Evia DR-T, Evia DR, Entovis SR-T, Entovis DR-T, Entovis DR, Estella SR-T, Estella DR-T, Estella DR,
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
95
0029
Alizea and Celea Pacemakers
3
PMA Approval
P
95
0037
Drug Eluting Permanent Right Ventricular (RV) or Right Atrial (RA) Pacemaker Electrodes
3
PMA Approval
P
95
0037
Pulse Generator, Permanent, Implantable
3
PMA Approval
P
95
0037
Pulse Generator, Permanent, Implantable
3
PMA Approval
P
95
0037
PSW 2100.U and NEO 2100.U
3
PMA Approval
P
95
0037
Evia SR-T, Evia SR, Evia DR-T, Evia DR, Entovis SR-T, Entovis SR, Entovis DR-T, Entovis DR, Estella SR-T, Estella DR-T,
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL and Verity ADx XL
3
PMA Approval
P
94
0031
VIGOR DR/SR, DISCOVERY, and MERIDIAN
3
PMA Approval
P
95
0037
Enticos 4 DR, Enticos 4 D, Enticos 4 SR, Enticos 4 S, Edora 8 DR-T, Evity 8 DR-T, Enitra 8 DR-T, Enticos 8 DR-T, Evity 6
3
PMA Approval
P
95
0029
Reply SR, Reply DR
3
PMA Approval
P
95
0037
Renamic Neo Programmer
3
PMA Approval
P
95
0037
Edora 8 DR-T, Evity 8 DR-T, Enitra 8 DR-T, Enticos 8 DR-T, Evity 6 DR-T, Enitra 6 DR-T, Edora 8 DR, Enitra 6 DR, Edora 8
3
PMA Approval
P
95
0037
Siello S 45 leads and Solia S 45 leads
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL
3
PMA Approval
P
95
0037
Dromos DR/SR Rate Adaptive Pacing Systems
3
PMA Approval
P
95
0037
Edora 8 DR-T, Evity 8 DR-T, Enitra 8 DR-T, Enticos 8 DR-T, Evity 6 DR-T, Enitra 6 DR-T, Edora 8 DR, Enitra 6 DR, Edora 8
3
PMA Approval
P
95
0037
Home Monitoring System Version 3.48
3
PMA Approval
P
88
0086
Assurity, Assurity+, and Endurity
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL
3
PMA Approval
P
95
0029
Reply SR, Reply DR, Esprit SR, and Esprit DR Pacemakers
3
PMA Approval
P
95
0029
Reply SR and Reply DR Pacemakers
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
95
0037
PSW 1904.U
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL, Sustain XL DC, Sust
3
PMA Approval
P
88
0086
Assurity, Endurity Core Family of Pacemakers
3
PMA Approval
P
95
0037
Pulse Generator, Permanent, Implantable
3
PMA Approval
P
95
0037
Pulse Generator, Permanent, Implantable
3
PMA Approval
P
95
0029
Reply SR and Reply DR Pacemakers
3
PMA Approval
P
95
0037
Pulse Generator, Permanent, Implantable
3
PMA Approval
P
95
0029
Reply SR and Reply DR Pacemakers
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL, Sustain XL DC, Sust
3
PMA Approval
P
95
0037
Drug Eluting Permanent Right Venticular/Right Atrial Pacemaker Electrodes, Stylets, Stylet, Catheter, Blind Plug, Perman
3
PMA Approval
P
88
0086
Endurity, Endurity Core, and Assurity pacemakers
3
PMA Approval
P
88
0086
Endurity, Assurity, and Accent
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemaker
3
PMA Approval
P
95
0037
Siello/Solia S Leads Tip
3
PMA Approval
P
88
0086
Endurity, Endurity Core, Assurity and Assurity +
3
PMA Approval
P
95
0037
Pulse Generator, Permanent Implantable DR-T/SR-T
3
PMA Approval
P
95
0037
Pulse Generator, Permanent Implantable, Pulse-Gererator, Pacemaker External, Adapter and Drug Eluting Permanent Right Ve
3
PMA Approval
P
88
0086
Assurity Pacemaker & Endurity Pacemaker
3
PMA Approval
P
14
0033
Assurity MRI Pacemakers and Endurity MRI Pacemakers
3
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
3
PMA Approval
P
95
0029
Reply/Esprit (5th generation) Electric Hybrid Module
3
PMA Approval
P
95
0037
Pulse Generator, Permanent, Inplantable
3
PMA Approval
P
95
0037
PSW 1901 U
3
PMA Approval
P
95
0037
Pulse Geneerator, Permanent, Implantable
3
PMA Approval
P
95
0037
Setrox S 53; Safio S 53; Dextrus 4136;TILDA R53;Solia S 45/53/60, JT 45/53; Siello S53/60/45/53/60/,JT 45/53;
3
PMA Approval
P
95
0037
Siello S45, S53, S60 and Solia S45, S53, S60
3
PMA Approval
P
94
0031
Accessory Kit
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
95
0037
PSW 1803.U / HMSC 3.40.2 / CardioMessenger Smart
3
PMA Approval
P
95
0037
Evia DR/SR; Evia DR-T/SR-T; Entovis DR/SR, Entovis DR-T/SR-T; Estella DR/SR; Estella DR-T/SR-T; Effecta D/S; Edora 8 DR/
3
PMA Approval
P
14
0033
Quadra Allure/ Quadra Allure MP Cardiac Resynchronization Therapy-Pacemaker (CRT-Ps)
3
PMA Approval
P
95
0037
Pulse Generator, Permanent Implantable, Drug-Eluting Permanent Right Ventricular (RV) or Right Atrial (RA) Pacemaker Ele
3
PMA Approval
P
14
0033
Tendril STS 2088TC Lead
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL and Sustain XL DC, S
3
PMA Approval
P
88
0086
Quartet, Victory, Zephyr, Accent, Assurity, Assurity+Endurity, Identity XL, Identity ADx XL, Verity ADx XL, Sustain XL D
3
PMA Approval
P
95
0037
PSW 1802.U, ACTROS, AXOS, BA03, CYLOS, DROMOS, KAIROS, PHILOS, PHILOS II, PROTOS, EVIA, ENTOVIS, ECURO, EFFECTA, ESTELLA
3
PMA Approval
P
95
0037
Siello S 45/53/60, Solia S 45/53/60, Siello T 53/60, Siello JT 45/53, Solia T 53/60, Solia JT 45/53, EFH-6F-W
3
PMA Approval
P
88
0086
Assurity / Assurity+ / Endurity
3
PMA Approval
P
95
0037
Siello T 53; Siello T 60; Siello JT 45; Siello JT 53; Solia T 53; Solia T 60; Solia JT 45; Solia JT 53
3
PMA Approval
P
95
0037
PSW 1801.U
3
PMA Approval
P
88
0086
Victory; Zephyr; Accent; Assurity; Assurity+; Endurity; Identity XL, Identity ADx XL; Verity ADxXL
3
PMA Approval
P
95
0037
Selox ST/JT; Siello S; Solia S; Setrox S; Safio S; S 45-K/53-K; DH; DH IS-1/DF4; EFH-6F-W; S53-K; S 45-S; S 53-S; S 45-F
3
PMA Approval
P
14
0033
Tendril MRI
3
PMA Approval
P
95
0037
Evia DR,DR-T,SR,SR-T; Entovis DR,DR-T,SR-T; Estella DR,DR-T,SR,SR-T; Effecta D,S; Edora 8 DR, 8 SR; Etrinsa 8 DR-T,SR-T,
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI
3
PMA Approval
P
88
0086
Assurity, Assurity +, Endurity, Accent and Victory XL
3
PMA Approval
P
95
0037
Evia DR /DR-T /SR/SR-T ;/Entovis DR /DR-T /SR /SR-T; Estella DR / DR-T/ SR /SR-T; Effecta D /S ;/ Endora 8 DR/ 8 SR; /
3
PMA Approval
P
95
0037
Siello S 45, Siello S 53, Siello S 60, Solia S 45, Solia S 53, Solia S 60
3
PMA Approval
P
14
0033
Tendril MRI
3
PMA Approval
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
3
PMA Approval
P
88
0086
Assurity, Assurity +, Endurity
3
PMA Approval
P
14
0033
Endurity MRI, Assurity MRI
3
PMA Approval
P
88
0086
Assurity, Assurity +, Endurity, Endurity Core
3
PMA Approval
P
14
0033
Assurity MRI, Endurity MRI
3
PMA Approval
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
14
0033
Assurity MRI Endurity MRI family of Pacemakers
3
PMA Approval
P
14
0033
Tendril MRI Leads (MRI)
3
PMA Approval
P
14
0033
Tendril
3
PMA Approval
P
95
0029
Pacemakers Reply SR/DR and Esprit SR/DR
3
PMA Approval
P
14
0033
Tendril MRI
3
PMA Approval
P
95
0029
Reply SR / Esprit SR / Reply DR / Esprit DR
3
PMA Approval
P
14
0033
Assurity MRI, Endurity MRI
3
PMA Approval
P
88
0086
Assurity, Endurity
3
PMA Approval
P
14
0033
Assurity MRI, Endurity MRI, Tendril MRI
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity ADx, Verity ADx
3
PMA Approval
P
95
0037
Selox ST/JT; Siello S; Setrox S, Solia S, Safio S
3
PMA Approval
P
95
0037
Dromos DR/DR-A and Dromos SR/SR-B Cardiac Pacing System
3
PMA Approval
P
14
0033
Accent MRI Pacemaker
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent, Identity ADx XL, Sustain XL, Verity ADx XL, Victory XL, and Zephyr XL
3
PMA Approval
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
3
PMA Approval
P
95
0029
REPLY & ESPRIT SR & DR Pacemakers
3
PMA Approval
P
14
0033
Tendril MRI Cardiac Lead
3
PMA Approval
P
88
0086
Medical Adhesive
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity
3
PMA Approval
P
95
0037
Siello, Solia, Setrox, and Safio
3
PMA Approval
P
14
0033
Low Voltage Active Fixation Lead
3
PMA Approval
P
95
0037
PSW 1704.U
3
PMA Approval
P
14
0033
Tendril MRI Leads
3
PMA Approval
P
14
0033
Tendril MRI
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI family of Pacemakers,
3
PMA Approval
P
88
0086
Accent, Assurity, Endurity, Verity ADx, Zephyr, Identity ADx, Victory
3
PMA Approval
P
14
0033
Assurity MRI, Endurity MRI
3
PMA Approval
P
95
0037
Siello S and Solia S, EFH-6F-W and DH IS-1/DF4
3
PMA Approval
P
14
0033
SJM MRI Activator
3
PMA Approval
P
88
0086
Assurity, Endurity, Accent, AddVent, Identity, Entity, Paragon III Sustain
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
14
0033
Assurity MRI PM1272, PM2272; Endurity MRI PM1172, PM2172
3
PMA Approval
P
88
0086
Victory 5816, 5810, 5610; Zephyr 5820, 5826, 5620, 5626; Accent PM1110, PM1210, PM2110, PM2210; Assurity PM1240, PM2240;
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
3
PMA Approval
P
14
0033
Endurity MRI ,Assurity MRI Pacemaker
3
PMA Approval
P
88
0086
Endurity Core, Endurity, Assurity+, Assurity, Sistain, Accent, Zephyr, Victory, Verify ADx XL, Identity Adx, Identity Pa
3
PMA Approval
P
95
0037
PK-222 and PK-Electrode Clip (accessory to Renamic)
3
PMA Approval
P
88
0086
Assurity, Assurity+, and Endurity
3
PMA Approval
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
3
PMA Approval
P
95
0037
PSW 1703.U
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
3
PMA Approval
P
14
0033
Assurity MRI, Endurity MRI family of Pacemakers
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity families of ICD Devices
3
PMA Approval
P
95
0037
Setrox S53, S60, Safio S 53, S 60, Solia S 45, S 53, S 60, Siello S 45, S 53, s 60, Blind plug BS IS-1
3
PMA Approval
P
14
0033
Endurity MRI, Assurity MRI
3
PMA Approval
P
88
0086
Endurity, Endurity Core, Assurity, Assurity+
3
PMA Approval
P
95
0029
Reply SR, Reply Dr, Esprit SR, Esprit DR (2nd generation , i.e. V2 ) & (5TH generation i.e.V5)
3
PMA Approval
P
95
0037
Edora, Evity, Enitra, Enticos 8SR/ SR-T/ DR/ DR-T
3
PMA Approval
P
95
0029
SMARTVIEW hotspot
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
3
PMA Approval
P
95
0037
Siello S 45, S53, S60 / Solia S 45, S53, S 60
3
PMA Approval
P
95
0037
Solia S
3
PMA Approval
P
95
0037
Edora / Enitra /Enticos / Evity PSW 1701.U
3
PMA Approval
P
95
0037
Pulse Generator, Permanent Implantable
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
3
PMA Approval
P
88
0086
Accent, Identity, Verity, Victory And Zephyr Pacemakers
3
PMA Approval
P
95
0037
PACEMAKER/ICD/CRT NON IMPLANTED COMPONENTS
3
PMA Approval
P
95
0037
Pacemaker/ICD/CRT non implanted components PSW 1602.U, HMSC 3.34.0
3
PMA Approval
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity ADx, Verity ADx
3
PMA Approval
P
14
0033
Assurity MRI, Endurity MRI, Tendril MRI
3
PMA Approval
P
95
0037
Edora 8 DR & DR-T, Evity 8 DR-T,Enitra 8 DR-T, Enticos 8 DR-T, Edora 8 SR-T and SR, Evity 8 SR-T, Enitra 8 SR-T,Enticos
3
PMA Approval
P
14
0033
Tendril MRI leads (MRI)
3
PMA Approval
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
3
PMA Approval
P
88
0086
PM1160, PM1240, PM1260, PM2160, PM2240, PM2260, PM1152, PM2152
3
PMA Approval
P
88
0086
AFFINITY/ INTEGRITY/ VICTORY/ ZEPHYR/ ACCENT FAMILY OF PACEMAKERS
3
PMA Approval
P
14
0033
Tendril MRI
3
PMA Approval
P
95
0037
PULSE GENERATOR, PERMANENT, IMPLANTABLE
3
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
3
PMA Approval
P
95
0037
PULSE GENERATOR, PERMANENT, IMPLANTABLE
3
PMA Approval
P
88
0086
ASSURITY, ASSURITY+, ENDURITY, ACCENT FAMILY OF PACEMAKERS
3
PMA Approval
P
95
0037
Linox smart TD 75/18/ 65/18/ 65/16; Linox smart SD 75/18/ 65/18/ 65/16 60/16; Linox smart T65/ S75/ D65/S60; Linox smart
3
PMA Approval
P
95
0029
Reply/Esprit Pacemakers Sorin CRM.
3
PMA Approval
P
95
0029
Repy SR/DR & Esprit SR/DR Pacemakers
3
PMA Approval
P
95
0037
Reocor S, Reocor D
3
PMA Approval
P
88
0086
Assurity, Assurity+, Endurity, Endurity Core
3
PMA Approval
P
95
0029
Reply Sr, Reply DR, Esprit SR, Esprit DR Pacemakers
3
PMA Approval
P
98
0049
Platinum VR/DR ICDS,Paradym RF VR/ RF DR CRT-Ds, Intensia VR, Intensia DR
3
PMA Approval
P
06
0027
Platinium, Paradym RF, RF VR, RF DR, Intensia CRT-Ds
3
PMA Approval
P
88
0086
Assurity - PM1240, PM2240, Assurity+ - PM1260, PM2260, Endurity - PM1160, PM2160, Endurity Core - PM1152, PM2152
3
PMA Approval
P
88
0086
ACCENT, IDENTITY, VERITY, VICTORY AND ZEPHYR PACEMAKERS
3
PMA Approval
P
95
0037
Various models of Evia, Entovis, Estella, Effecta, Ecuro, Eluna, Etrinsa, Epyra Pulse Generator Families
3
PMA Approval
P
95
0029
REPLY SR, REPLY DR, ESPRIT SR, ESPRIT DR Pacemakers
3
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
3
PMA Approval
P
88
0086
Verity 5056, 5156, 5256, 5356, 5456, 5816; Zephyr 5826, 5626; Identity 5286, 5386; Sustain XL PM1134, PM1136, PM2134, PM
3
PMA Approval
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
3
PMA Approval
P
91
0023
ST.JUDE MEDICAL ICDS/CRT-D
3
PMA Approval
P
99
0001
VITATRON SOFTWARE MULTIPLE SOFTWARE MODELS
3
PMA Approval
P
89
0003
CARELINK PROGRAMMER (MODEL 2090)/ANALYZER (MODEL 2290)
3
PMA Approval
P
95
0029
SYMPHONY/ELA RHAPSODY PACEMAKER SYSTEM AND THE ORCHESTRA PROGRAMMER
3
PMA Approval
P
88
0086
AFFINITY, IDENTITY, INTEGRITY, AND FRONTIER FAMILY OF DEVICES
3
PMA Approval
P
88
0086
AFFINITY, IDENTITY, INTEGRITY, AND FRONTIER FAMILY OF DEVICES
3
PMA Approval
P
98
0035
KAPPA 700/650/600, KAPPA 900/800 AND ENPULSE E1/E2
3
PMA Approval
P
89
0003
2020A CARDIOSIGHT READER AND MODEL 2491 DEVICE DATA MANAGEMENT
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 2490G CARELINK MONITOR AND MODEL 2491 DDMA SOFTWARE
3
PMA Approval
P
88
0086
PULSE GENERATOR
3
PMA Approval
P
95
0037
PROTOS DR/CLS AND PROTOS VR/CLS
3
PMA Approval
P
98
0035
AT500 DDDRP PACING SYSTEM (MODEL AT500) AND MODEL 9968 SOFTWARE POST-MARKET (RESPECT): ADDING THE ENRHYTHM MODEL P1501DR
3
PMA Approval
P
91
0023
HOUSECALL PLUS TRANSTELEPHONIC MONITORING SYSTEM WITH MODEL 3180-R RECEIVER SOFTWARE (VERSION 2.1)
3
PMA Approval
P
95
0037
IMPLANT CONTROL SYSTEM (ICS) 3000
3
PMA Approval
P
91
0023
CADENCE (R) TIERED THERAPY DEFIBRILLATOR SYSTEM
3
PMA Approval
P
98
0035
MEDTRONIC MODEL P1501DR ENRHYTHM IMPLANTABLE PULSE GENERATOR, MEDTRONIC MODEL 9987 APPLICATION SOFTWARE AND MEDTRONIC MO
3
PMA Approval
P
95
0029
SYMPHONY DR 2550 MODE AND ELAVIEW 1.28 UG1 PROGRAMMING SOFTWARE
3
PMA Approval
P
88
0086
PRE-MOLDED HEADER CONNECTOR DESIGN FOR THE INTEGRITY DR MODEL 5336, IDENTITY DR MODEL 5370, IDENTITY ADX DR MODEL 5380,
3
PMA Approval
P
89
0003
MEDTRONIC MODELS 2490G AND 2490J CARELINK MONITORS AND MODEL 2491 DDMA SOFTWARE
3
PMA Approval
P
99
0001
VITATRON C60 DR (MODEL C60A3) AND VITATRON C20 SR (MODEL C20A3) IMPLANTABLE PULSE GENERATORS AND THEIR ASSOCIATED SOFTWA
3
PMA Approval
P
88
0086
SYCHRONY PULSE GENERATOR
3
PMA Approval
P
91
0023
EPIC AND EPIC+ DR/VR ICD SYSTEMS WITH N2 CAPACITOR
3
PMA Approval
P
95
0029
ELA MEDICAL RATE-RESPONSIVE PACEMAKERS
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 2090 CARELINK PROGRAMMER WITH TELEMETRY C
3
PMA Approval
P
89
0003
CARELINK MONITOR MODELS 2490G, 2490H AND 2490J
3
PMA Approval
P
91
0023
CADENCE TIERED-THERAPY DEFIBRILLATOR SYSTEM
3
PMA Approval
P
91
0020
RELAY
3
PMA Approval
P
98
0035
KAPPA 700, KAPPA 900, ENPULSE
3
PMA Approval
P
99
0001
SELECTION AFM, VITATRON C60 DR, C20 SR, T60 DR, AND T20 SR PACING SYSTEMS
3
PMA Approval
P
88
0086
IDENTITY/IDENTITY ADX, INFINITY AND INTEGRITY FAMILIES OF PACEMAKERS
3
PMA Approval
P
91
0020
RELAY
3
PMA Approval
P
95
0037
SELOX ST/JT STEROID-ELUTING PASSIVE-FIXATION ENDOCARDIAL PACKING LEAD MODELS SELOX ST 53, SELOX ST 60, SELOX JT 45 & 53
3
PMA Approval
P
95
0029
SYMPHONY & ELA RHAPSODY PACEMAKERS
3
PMA Approval
P
89
0003
2490D/E CARELINK MONITORS
3
PMA Approval
P
89
0003
MODEL 2490G/ 2490H/2490J CARELINK MONITORS FOR USE WITH MODEL 2491 DDMA SOFTWARE
3
PMA Approval
P
97
0012
MEDTRONIC KAPPA 400 SERIES PACEMAKERS
3
PMA Approval
P
89
0003
VITATRON LEGACY 11 DR
3
PMA Approval
P
98
0035
KAPPA 700, 800, 900/SIGMA/ENPULSE
3
PMA Approval
P
89
0003
MODEL 9879 SOFTWARE FOR THERA/THERA-I/PRODIGY DEVICES, MODEL 9849 SOFTWARE FOR THE LEGACY II/VISA DEVICES, MODEL 9847...
3
PMA Approval
P
98
0035
MEDTRONIC ENPULSE IMPLANTABLE PULSE GENERATOR AND MODEL 9991 APPLICATIONS SOFTWARE
3
PMA Approval
P
88
0086
MODEL 3150 PACING SYSTEM ANALYZER WAND AND THE MODEL 3307 V4.7 PROGRAMMER SOFTWARE FOR USE WITH MODEL 3510 PROGRAMMERS
3
PMA Approval
P
95
0029
SYMPHONY AND ELA RHAPSODY PACEMAKERS
3
PMA Approval
P
99
0001
VITATRON T60 DR AND T20 SR SYSTEMS
3
PMA Approval
P
98
0035
AT500 DDDRP PACING SYSTEM
3
PMA Approval
P
91
0023
HOUSECALL PLUS TRANSTELEPHONIC MONITORING SYSTEM WITH MODEL 3180-T TRANSMITTER AND MODEL 3180-R RECEIVER SOFTWARE (VERS
3
PMA Approval
P
91
0023
EPIC+ VR MODEL V-196T AND EPIC+ DR MODEL V-239T
3
PMA Approval
P
88
0086
EPIC + DR/VR IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
3
PMA Approval
P
98
0035
ENPULSE IMPLANTABLE PULSE GENERATOR, MODELS E1DR01, E1DR03, E1DR06, E1DR21 AND MODEL 9991 V 2.0 APPLICATION SOFTWARE
3
PMA Approval
P
95
0037
PHILOS DR-T PULSE GENERATOR AND A-K00.1.U/5 PROGRAMMER SOFTWARE
3
PMA Approval
P
95
0037
PHILOS II DR, PHILOS II D, PHILOS II DR-T, PHILOS II SLR, PHILOS II SR, PHILOS II S, AND PROGRAMMER SOFTWARE VERSION A-U
3
PMA Approval
P
98
0035
MEDTRONIC MODEL 2490D CARELINK MONITORS AND MODEL 2491 DDMA SOFTWARE FOR ENPULSE MODELS
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 2490D CARELINK MONITOR
3
PMA Approval
P
98
0035
MEDTRONIC ENPULSE IMPLANTABLE PULSE GENERATOR AND MODEL 9991 APPLICATION SOFTWARE
3
PMA Approval
P
98
0035
MEDTRONIC SIGMA MODELS SS106, SSR306, SC203, SDR203, SD303, SDR303, DR353 AND SVDD303
3
PMA Approval
P
95
0029
SYMPHONY/ELA RHAPSODY ROM MASK T3 (VERSION GXD T3)
3
PMA Approval
P
88
0086
VERITY ADX XL VDR MODEL 5456I PULSE GENERATOR
3
PMA Approval
P
89
0003
2490D/E CARELINK MONITORS & MODEL 2491 DDMA SOFTWARE FOR INSYNC MARQUIS & MAXIMO VR/DR CAPABILITY
3
PMA Approval
P
98
0035
ENPULSE INPLANTABLE PULSE GENERATOR
3
PMA Approval
P
95
0037
PHILOS DR-T PULSE GENERATOR/ICD BELOS VR-T,DR-T,ICD CARDIAC AIRBAG-T
3
PMA Approval
P
89
0003
SYNERGYST PULSE II GENERATOR
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 700/600 SERIES
3
PMA Approval
P
97
0012
MEDTRONIC. KAPPA 400 SERIES PACEMAKERS
3
PMA Approval
P
91
0023
HOUSECALL PLUS TRANSTELEPHONIC MONITORING SYSTEM WITH MODEL 3180-T TRANSMITTER (SOFTWARE VERSION 1.1) AND MODEL 3180-R
3
PMA Approval
P
88
0086
SYNCHRONY MODEL 2020T PULSE GENERATOR
3
PMA Approval
P
95
0029
SYMPHONY/ELA RHAPSODY PACEMAKER SYSTEM
3
PMA Approval
P
88
0086
ATLAS+ DR/VR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND MODEL 3307 V.4.5A SOFTWARE
3
PMA Approval
P
91
0023
ATLAS+ DR/BR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND MODEL 3307 V.4.5A SOFTWARE
3
PMA Approval
P
98
0035
MEDTRONIC AT500 DDDRP PACING SYSTEM (MODEL AT501) AND MODEL 9968 SOFTWARE
3
PMA Approval
P
89
0003
SYNERGYST II PULSE GENERATOR
3
PMA Approval
P
99
0001
VITATRON DA+ C SERIES PULSE GENERATORS
3
PMA Approval
P
91
0023
ADX PULSE GENERATOR
3
PMA Approval
P
88
0086
ADX PULSE GENERATOR FIRMWARE ANOMALY CORRECTION
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 900/800 PACEMAKER SERIES
3
PMA Approval
P
95
0037
PHILOS DR ACC PACING SYSTEM AND PROGRAMMER SOFTWARE VERSION B-KAC.V.U/1
3
PMA Approval
P
98
0035
MEDTRONIC SIGMA PACING SYSTEM AND MEDTRONIC 350 SERIES PACING SYSTEM
3
PMA Approval
P
99
0001
MODEL VSA02/VSC02 V9.0 PROGRAMMING SOFTWARE FOR THE DIVA, DEMA, AND SELECTION AFM MODEL 902 PULSE GENERATORS
3
PMA Approval
P
88
0086
IDENTITY ADX XL DC,& SR/ADX VDR/ADX XL DR,DR,SR/VERITY ADX XL VDR/ADX XL DR,DR,DC/ADX XLSR,SR,SC
3
PMA Approval
P
91
0023
IDENTITY ADX XL DC,SR/ADX VDR/ADX XL DR,DR,SR/VERITY ADX XL VDR/ADX XL DR,DR,DC/ADX XLSR,SR,SC
3
PMA Approval
P
88
0086
EPIC PLUS VR/DR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
3
PMA Approval
P
98
0035
AT500DDDRP PACING SYSTEM & MODEL 9968 SOFTWARE
3
PMA Approval
P
88
0086
IDENTITY ADX MODELS XL DR 5386 AND DR 5380 PULSE GENERATORS AND PROGRAMMER SOFTWARE MODEL 3307 V4.2A
3
PMA Approval
P
95
0037
CARDIOMESSENGER HOME MONITORING SYSTEM
3
PMA Approval
P
98
0035
MODEL 2490D/E CARELINK MONITORS AND THE SERVER-BASED MODEL 2491 DEVICE DATA MANAGEMENT SOFTWARE APPLICATION (DDMA)
3
PMA Approval
P
97
0012
KAPPA 400
3
PMA Approval
P
99
0001
DIVA PLATFORM,DERMA PLATFORM
3
PMA Approval
P
98
0035
KAPPA 700/600, 900/800, SIGMA/MEDTRONIC 350
3
PMA Approval
P
88
0086
APPLICATION SOFTWARE MODEL 3307 (VERSION 4.1A)
3
PMA Approval
P
95
0037
PROTOS FAMILY OF PULSE GENERATORS
3
PMA Approval
P
95
0029
TALENT II DUAL-SENSOR IMPLANTABLE CARDIAC PACEMAKERS, MODELS DR233 AND SR133
3
PMA Approval
P
95
0037
PROTOS PULSE GENERATOR (PROTOS VR AND PROTOS DR) AND B-K00.P.U AND A-K00.0.U PROGRAMMER SOFTWARE
3
PMA Approval
P
88
0086
MODEL 3307, V4.0A PROGRAMMING SOFTWARE AND MODEL 3160 ECG ADAPTER CABLE
3
PMA Approval
P
88
0086
ST JUDE MEDICAL EPIC VR/DR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (MODELS V-197 AND V-235)
3
PMA Approval
P
89
0003
MODEL 9896 SOFTWARE FOR THE JEWEL MODEL 7218
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 700 SERIES OF IPGS
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 700 SERIES PULSE GENERATOR PRODUCT FAMILY
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 700/600/800/900 PULSE GENERATORS
3
PMA Approval
P
93
0022
LEGEND PLUS PACEMAKER FAMILY
3
PMA Approval
P
97
0012
KAPPA 400 PACEMAKER FAMILY
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA/SIGMA PACEMAKER FAMILIES
3
PMA Approval
P
99
0001
DEMA/DIVA IMPLANTABLE PULSE GENERATORS
3
PMA Approval
P
89
0003
MEDTRONIC/VITATRON CARELINK PROGRAMMER
3
PMA Approval
P
89
0003
MEDTRONIC PACING LEADS
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 900/800 SERIES PLUSE GENERATORS
3
PMA Approval
P
99
0001
PROVIT MODEL VSA02 VERSION 6.1 SOFTWARE BUILD 63 SERVICE RELEASE FOR DEMA, DIVA AND SELECTION AFM FAMILIES OF PULSE GENS
3
PMA Approval
P
98
0035
KAPPA 900/800 IMPLANTABLE PULSE GENERATOR FAMILY SERIES
3
PMA Approval
P
89
0003
THERA/THERA-I
3
PMA Approval
P
98
0035
MEDTRONIC SIGMA AND MEDTRONIC 350 SERIES PULSE GENERATORS
3
PMA Approval
P
88
0086
ATLAS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SYSTEM
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 900/800 SERIES PACING SYSTEM
3
PMA Approval
P
89
0003
THERA/THERA-I FAMILY OF PULSE GENERATORS
3
PMA Approval
P
98
0035
KAPPA 700/600, SIGMA AND 350 SERIES FAMILIES OF PULSE GENERATORS
3
PMA Approval
P
97
0012
KAPPA 400
3
PMA Approval
P
99
0001
DEMA/DIVA IMPLANTABLE PULSE GENERATORS
3
PMA Approval
P
88
0086
IDENTITY XL DR MODEL 5376 PULSE GENERATOR
3
PMA Approval
P
95
0029
TALENT AND BRIO PACEMAKERS
3
PMA Approval
P
98
0035
MEDTRONIC KAPPA 700/600 PULSE GENERATOR
3
PMA Approval
P
99
0001
DEMA/DIVA IMPLANTABLE PULSE GENERATORS
3
PMA Approval
P
97
0012
KAPPA 400 IMPLANTABLE PULSE GENERATOR
3
PMA Approval
P
88
0086
INTEGRITY AFX DR MODEL 5346
3
PMA Approval
P
88
0086
MODEL 3307 VERSION 2.4A PROGRAMMER SOFTWARE
3
PMA Approval
P
89
0003
MEDTRONIC PACING LEADS
3
PMA Approval
P
88
0086
INTEGRITY AFX DR MODEL 5346 DUAL CHAMBER PULSE GENERATOR AND PROGRAMMER SOFTWARE MODEL 3307, V2.2A
3
PMA Approval
P
95
0029
TALENT PULSE GENERATOR MODELS DR233 AND SR 133 AND PROGRAMMER SOFTWARE CSO 4.18 UG
3
PMA Approval
P
89
0003
MEDTRONIC REVEAL PLUS INSERTABLE LOOP RECORDER (ILR) WITH UPDATED TO THE APPLICATION SOFTWARE (MODEL 09-9 SERIES 2.0)
3
PMA Approval
P
89
0003
9767/9767L PROGRAMMING HEAD AND MODEL9990 DESKTOP SOFTWARE
3
PMA Approval
P
97
0012
MEDTRONIC KAPPA 400 PACING SYSTEM WITH MODEL 9952 VISION - SERIOE 1.3 SOFTWARE
3
PMA Approval
P
99
0001
DEMA, DIVA AND AFM PULSE GENERATORS
3
PMA Approval
P
88
0086
VENTRITEX ICD'S USING MODEL 3307, V2.1A PROGRAMMER SOFTWARE
3
PMA Approval
P
95
0029
BRIO, TALENT, AND OPUS PACEMAKERS AND PROGRAMMER SOFTWARE
3
PMA Approval
P
99
0001
VITATRON DIVA PLATFORM
3
PMA Approval
P
88
0086
INTEGRITY U DR MODEL 5336 AND SR MODEL 5136 PULSE GENERATORS
3
PMA Approval
P
88
0086
VENTRITEX ICD'S
3
PMA Approval
P
88
0086
AFFINITY FAMILY OF PULSE GENERATORS
3
PMA Approval
P
99
0001
VITATRON(R) DEMA PACING SYSTEM
3
PMA Approval
P
95
0029
ELA RATE-RESPONSIVE PACEMAKERS
3
PMA Approval
P
95
0029
TALENT AND BRIO PACEMAKERS (RIGID CONNECTOR)
3
PMA Approval
P
88
0086
INTEGRITY AFX DR/INTEGRITY SR
3
PMA Approval
P
89
0003
MEDTRONIC 9790/9790C PROGRAMMER
3
PMA Approval
P
95
0029
ELA RATE-RESPONSIVE PACEMAKERS
3
PMA Approval
P
88
0086
AV PLUS DX
3
PMA Approval
P
88
0086
AV PLUS DX MODEL 1368 LEAD
3
PMA Approval
P
88
0086
AFFINITY PULSE GENERATORS
3
PMA Approval
P
99
0001
VITATRON DIVA PACING SYSTEM
3
PMA Approval
P
89
0003
SYNERGYST II PMA FAMILY OF IMPLANTABLE PULSE GENERATORS
3
PMA Approval
P
88
0086
MODEL 3307 V1.2A PROGRAMMER SOFTWARE FOR THE MODEL 3500/3510 PROGRAMMERS
3
PMA Approval
P
88
0086
MODEL 3264 REV. B PROGRAMMER SOFTWARE FOR THE APSU MODEL 3250 PROGRAMMER
3
PMA Approval
P
95
0029
TALENT MODEL 213 DUAL-CHAMBER, DUAL SENSOR, IMPLANTABLE CARDIAC PACEMAKER, ELA MEDICAL PROGRAMMER
3
PMA Approval
P
88
0086
INTEGRITY AFX DR (MODEL 5342) & SR (MODEL 5142) PULSE GENERATORS
3
PMA Approval
P
88
0086
AFFINITY VDR MODEL 5430 PULSE GENERATOR
3
PMA Approval
P
88
0086
TRILOGY/SOLUS/PARAGON III/PHOENIX III/SYNCHRONY II,III/ADDVENT TEMPO
3
PMA Approval
P
88
0006
REGENCY SC+, REGENCY SC, REGENCY SCX
3
PMA Approval
P
88
0086
3500/3510 PROGRAMMER
3
PMA Approval
P
89
0003
REVEAL PLUS INSERTABLE LOOP RECORDER MODEL 9809 SOFTWARE
3
PMA Approval
P
97
0012
MEDTRONIC VISION SOFTWARE
3
PMA Approval
P
95
0029
MULTI-PARTITION OPERATING ENVIRONMENT FOR ELA PROGRAMMERS
3
PMA Approval
P
91
0020
IMPLANTABLE PACEMAKER LEADS
3
PMA Approval
P
95
0029
PROGRAMMING SOFTWARE UPGRADE (CSO 4.10 UG)
3
PMA Approval
P
99
0001
VITATRON DIVA IMPLANTABLE PULSE GENERATORS
3
PMA Approval
P
99
0001
VITATRON DIVA
3
PMA Approval
P
88
0086
TENDRIL/PASSIVE PLUS/AV PLUS DX
3
PMA Approval
P
88
0038
NETWORK PROGRAMMER
3
PMA Approval
P
88
0006
SOFTWARE MODEL 3264 REV A
3
PMA Approval
P
88
0086
CARDIAC PACEMAKER PROGRAMMER & BASE STATION
3
PMA Approval
P
90
0070
R5.111WE(REVISION OF R5.85WE)
3
PMA Approval
P
95
0029
BRIO CARDIAC PACEMAKERS
3
PMA Approval
P
88
0086
POLARITY PULSE GENERATOR MODELS 209K AND 2091M/S
3
PMA Approval
P
95
0029
BRIO CARDIAC PACEMAKERS DUAL CHAMBER/DUAL CHAMBER RATE RESPONSIVE
3
PMA Approval
P
95
0037
ACTROS+ FAMILY OF PULSE GENERATORS
3
PMA Approval
P
95
0037
ACTROS SLR+,KAIROS SL PULSE GENERATORS;SL 60-11,13,15 BP SINGLE PASS PACING LEAD;SWM 1000 B-G01.0.U
3
PMA Approval
P
88
0086
AFFINITY/ENTITY DR,DC,SR
3
PMA Approval
P
88
0086
ADDVENT/AV PLUS DX
3
PMA Approval
P
95
0037
ACTROS DR+ -B PULSE GENERATOR
3
PMA Approval
P
88
0086
ADDVENT MODEL 2060LR PULSE GENERATOR AV PLUS SINGLE PASS LEAD MODEL 1328C
3
PMA Approval
P
97
0012
MEDTRONIC KAPPA 400 SERIES IPG'S
3
PMA Approval
P
88
0086
AFFINITY SR MODELS 5130 (LS,RS,L,R)PULSE GENERATORS AFFINITY DR MODELS 5330 (LS, RS,L,R)PULSE GENERATORS
3
PMA Approval
P
88
0086
AFFINITY DR & AFFINITY SR PULSE GENERATORS
3
PMA Approval
P
95
0037
ACTROS+
3
PMA Approval
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
3
PMA Approval
P
95
0037
KAIROS
3
PMA Approval
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
3
PMA Approval
P
95
0029
OPUS RM 4534 AND CHORUS RM 7034 PACEMAKERS
3
PMA Approval
P
89
0039
POLY-SAFE(TM) A-TRACK(TM) PACING LEADS
3
PMA Approval
P
88
0086
TRILOGY FAMILY OF PULSE GENERATORS
3
PMA Approval
P
90
0070
TEMPO FAMILY OF PULSE GENERATORS
3
PMA Approval
P
88
0086
APS III PROGRAMMER WITH SOFTWARE MODEL 3302 REV.D (V1.04)
3
PMA Approval
P
97
0012
MEDTRONIC VISION SOFTWARE MODEL 9952-SERIES 2.1 AND MEDTRONIC. VISION SOFTWARE MODEL 9952A-SERIES 2.1
3
PMA Approval
P
88
0086
SYNCHRONY, SOLUS, PHOENIX, PARAGON AND TRILOGY FAMILY OF PULSE GENERATORS
3
PMA Approval
P
90
0070
TEMPO AND META PULSE GENERATORS
3
PMA Approval
P
88
0006
REGENCY SC, SC+, AND SCX FAMILY OF PULSE GENERATORS
3
PMA Approval
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
3
PMA Approval
P
95
0037
ACTROS DR,D,SR, AND S PULSE GENERATORS AND PMS 1000C PROGRAMMING AND MONITORING SYSTEM
3
PMA Approval
P
89
0003
MODEL 8090 ANALYZER MODEL 5436 ANALYZER PATIENT CABLE, 5104/5104ANALYZER ADAPTORS, AND 8190 ANALYZER SOFTWARE
3
PMA Approval
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
3
PMA Approval
P
88
0006
APSU PROGRAMMER, APSU SOFTWARE, BASE STATION
3
PMA Approval
P
88
0086
APSU PROGRAMMER, APSU SOFTWARE, BASE STATION
3
PMA Approval
P
88
0086
APSU PROGRAMMER, APSU SOFTWARE, BASE STATION
3
PMA Approval
P
90
0070
TEMPO PULSE GENERATORS
3
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
3
PMA Approval
P
95
0037
ACTROS DR,D,SR, AND S PULSE GENERATORS AND PMS 1000C PROGRAMMING AND MONITORING SYSTEM
3
PMA Approval
P
89
0003
MODEL 9790C PROGRAMMER AND MODEL 9891 PE SOFTWARE
3
PMA Approval
P
91
0020
COSMOS, STRIDE, DASH, DART, UNITY, NOVA, QUANTUM PULSE GENERATORS
3
PMA Approval
P
88
0086
POLARITY PULSE GENERATOR MODELS 209K AND 2091M/S
3
PMA Approval
P
88
0086
POLARITY PULSE GENERATOR MODELS 209K AND 2091M/S
3
PMA Approval
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
3
PMA Approval
P
89
0003
MODEL 9790C PROGRAMMER AND MODEL 9891 PE SOFTWARE
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 5038 CAPSURE VDD-2 LEAD
3
PMA Approval
P
89
0003
MODEL 9790C PROGRAMMER AND MODEL 9891 PE SOFTWARE
3
PMA Approval
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
3
PMA Approval
P
91
0020
COSMOS, STRIDE, DASH, DART, UNITY, NOVA, QUANTUM PULSE GENERATORS
3
PMA Approval
P
88
0006
APS II 3003 PROGRAMMER WITH MODEL 3203A FUNCTION PACK
3
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
3
PMA Approval
P
91
0020
MOMENTUM PACERS
3
PMA Approval
P
89
0003
MODEL 9802 E REVEAL INSERTABLE LOOP RECORDER SOFTWARE
3
PMA Approval
P
88
0086
TRILOGY DC+ MODEL 2318L PULSE GENERATOR
3
PMA Approval
P
89
0003
PREVA, PRODIGY, VITATRON AND THERA PACEMAKERS
3
PMA Approval
P
91
0020
EDGEBAND PACER RELAY MODEL 294-03E
3
PMA Approval
P
96
0004
ADDITION OF ALTERNATE TUBING EXTRUDER
3
PMA Approval
P
90
0070
TEMPO PULSE GENERATORS
3
PMA Approval
P
90
0070
MODEL 1256D META MV CARDIAC PULSE GENERATOR
3
PMA Approval
P
88
0086
APS III MODEL 3500 PROGRAMMER
3
PMA Approval
P
96
0004
THINLINE ENDOCARDIAL PACING LEADS
3
PMA Approval
P
90
0070
TEMPO VR 1102 AND TEMPO V 1902
3
PMA Approval
P
90
0070
TEMPO DR 2102 AND TEMP D 2902
3
PMA Approval
P
90
0070
META DDDR MODEL 1256 PULSE GENERATOR
3
PMA Approval
P
91
0020
MOMENTUM PACERS
3
PMA Approval
P
88
0086
TRILOGY DR+ PULSE GENERATOR MODELS 2360L AND 2364L PULSE GENERATORS MODELS 2360L AND 2364L
3
PMA Approval
P
88
0006
APS II 3003 PROGRAMMER WITH MODEL 3203A FUNCTION PACK
3
PMA Approval
P
88
0038
MODEL 9602 PROGRAMMER
3
PMA Approval
P
90
0070
MODEL 1256D META MV CARDIAC PULSE GENERATOR
3
PMA Approval
P
90
0070
MODEL 1256D META MV CARDIAC PULSE GENERATOR
3
PMA Approval
P
88
0086
TRILOGY SR+ MODEL 2260L & 2264L CARDIAC PULSE GENERATORS WITH THE MODEL 3023 PDX FUNCTION PACK
3
PMA Approval
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
3
PMA Approval
P
91
0020
MARATHON PACING SYSYTEM
3
PMA Approval
P
88
0086
TRILOGY DC + PULSE GENERATOR, MODEL 2318L
3
PMA Approval
P
90
0070
META DDDR PACEMAKER PULSE GENERATORS MODELS 1256, 1256D, & 1256B (FORMERLY 1256R)
3
PMA Approval
P
88
0006
SENSOLOG(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
90
0070
TEMPO DR 2102 AND TEMP D 2902
3
PMA Approval
P
89
0003
PREVA ST DR MODEL 7078 AND THE PREVA D MODEL 7068 IMPLANTABLE PULSE GENERATORS, AND MODEL 9559 SOFTWARE
3
PMA Approval
P
89
0003
SYNERGYST II,ELITE & LEGEND PULSE GENERATORS
3
PMA Approval
P
89
0003
MEDTRONIC 9766A/9766AL PROGRAMMING HEAD
3
PMA Approval
P
88
0006
APS II 3003 PROGRAMMER WITH MODEL 3203A FUNCTION PACK
3
PMA Approval
P
91
0020
MARATHON PACING SYSYTEM
3
PMA Approval
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
3
PMA Approval
P
88
0086
SYNCHRONY,SYNCHRONY II & III SOLUS, SOLUS II & TRIOLOGY PACEMAKERS
3
PMA Approval
P
88
0038
META(TM) III PULSE GENERATOR MODELS 1206, 1206E, 1206M
3
PMA Approval
P
88
0086
TRILOGY DR+ PULSE GENERATOR MODELS 2360L AND 2364L PULSE GENERATORS MODELS 2360L AND 2364L
3
PMA Approval
P
89
0003
MEDTRONIC 9891 BASELINE SOFTWARE/9891 A EPS
3
PMA Approval
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
3
PMA Approval
P
89
0003
MEDTRONIC VDD STEROID-ELUTING LEAD
3
PMA Approval
P
91
0020
UNITY MODEL 292-06 SINGLE PASS PULSE GENERATOR
3
PMA Approval
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
88
0038
MEDA-MV PACING SYSTEM
3
PMA Approval
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
88
0038
MEDA-MV PACING SYSTEM
3
PMA Approval
P
89
0039
MAESTRO(R) II SAVVI(TM) PACING SYS MODEL 325 & 333
3
PMA Approval
P
89
0003
MEDTRONIC THERA, PRODIGY AND PREVA PULSE GENERATORS
3
PMA Approval
P
90
0070
NETWORK PROGRAMMER MODEL 9602
3
PMA Approval
P
88
0038
NETWORK PROGRAMMER MODEL 9602
3
PMA Approval
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
91
0020
MARATHON FAMILY OF PULSE GENERATORS AND THE MODEL 531-66
3
PMA Approval
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(R) VDD, MODEL 896I, PRODIGY(TM) VDD, MODEL 8168 PULSE GENERATORS AND CAPURE(R) VDD, MODEL 5032 LEAD,
3
PMA Approval
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
3
PMA Approval
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
3
PMA Approval
P
89
0003
MEDTRONIC SYNERGYST II PULSE GENERATOR SYSTEM
3
PMA Approval
P
88
0006
AFP CARDIAC PACING SYSTEM, SENSOLOG CARDIAC PACING SYSTEM, AND SYNCHRONY CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0086
AFP CARDIAC PACING SYSTEM, SENSOLOG CARDIAC PACING SYSTEM, AND SYNCHRONY CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0086
TRILOGY PULSE GENERATOR MODELS 235OL, 2250L, AND 2308L
3
PMA Approval
P
88
0086
SYNCHRONY III AND PARAGON III DUAL-CHAMBER PULSE GENERATORS
3
PMA Approval
P
89
0003
SYNERGYST II MEDTRONIC MODEL 9889E SOFTWARE
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
88
0038
MEDA-MV PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
87
0054
KELVIN(R) MODEL 513 UNIPOLAR AND MODEL 514 BIPOLAR CARDIAC PULSE GENERATORS.
3
PMA Approval
K
94
0039
PELLETHANE 75D
3
Cleared 510(K)
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
94
0031
VIGOR(TM) DR PACEMAKER SYSTEM
3
PMA Approval
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
89
0039
MAESTRO(R) II SAVVI(TM) PACING SYS MODEL 325 & 333
3
PMA Approval
K
95
0751
TECOTHANE 75D POLYURETHANE RESIN FOR PULSE GENERATOR CONNECTOR MODULES
3
Cleared 510(K)
K
94
6188
CCDS MAESTRO(R) II SERIES 200 CADIAC PACEMAKER
3
Cleared 510(K)
K
95
0210
CCS MAESTRO(R) II SERIES 200 MODELS 235 AND 227 CARDIAC PACEMAKER
3
Cleared 510(K)
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
3
PMA Approval
P
88
0006
SENSOLOG(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
89
0003
MEDTRONIC DUAL CHAMBER PACEMAKERS
3
PMA Approval
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
91
0020
UNITY - C MODEL 292-06 PULSE GENERATOR & ACCS.
3
PMA Approval
P
91
0020
RELAY-DASH PACING SYSTEM
3
PMA Approval
P
91
0020
RELAY-DASH PACING SYSTEM
3
PMA Approval
P
88
0006
SENSOLOG (R) ULTILOG (TM) MODELS 2040K,2040T
3
PMA Approval
P
89
0003
MEDTRONIC(R) MODEL 9870A SOFTWARE DISKETTES
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
3
PMA Approval
P
89
0039
CCS MODEL 325 PACEMAKER SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC(R) SYNERGYST II
3
PMA Approval
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0086
SYNCHRONY MODELS PARAGON III/PHOENIX III PACERS
3
PMA Approval
P
89
0003
MEDTRONIC DUAL CHAMBER PACEMAKERS
3
PMA Approval
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0006
OG(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC DUAL CHAMBER PACEMAKERS
3
PMA Approval
K
94
1937
PIKOS E 01-B
3
Cleared 510(K)
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0006
SENSOLOG (R)MODEL 3039 FUNCTION PACK
3
PMA Approval
P
88
0086
SYNCHRONY PACING SYS. MODEL 3039 FUNCTION PACK
3
PMA Approval
P
88
0086
SYNCHRONY PACING SYS. MODEL 385 FUNCTION PACK
3
PMA Approval
P
91
0020
RELAY-DASH PACING SYSTEM
3
PMA Approval
P
91
0020
RELAY/DASH/STRIDE & DART PACING SYSTEM
3
PMA Approval
K
93
2884
MINIX/MINIX ST PULSE GENERATORS
3
Cleared 510(K)
P
89
0039
MAESTRO(R) II SAVVI(TM) PACING SYS MODEL 325 & 333
3
PMA Approval
P
89
0003
MEDTRONIC ELITE II(TM) PULSE GENERATOR
3
PMA Approval
P
88
0038
MEDA-MV PACING SYSTEM
3
PMA Approval
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC SYNERGYST II PULSE GENERATOR
3
PMA Approval
P
89
0003
MEDTRONIC ELITE II MODEL 7086
3
PMA Approval
P
89
0039
CCS MODEL 325 PACEMAKER SYSTEM
3
PMA Approval
K
92
3026
PIKOS 01-A AND PIKOS E01-A IMPLANTABLE PACEMAKER
3
Cleared 510(K)
P
89
0003
MEDTRONIC MODEL 5424 ELECTROCARDIOGRAM CABLE
3
PMA Approval
P
90
0070
META DDDR PACING SYSTEM MODEL 1254/FUNC.1250H
3
PMA Approval
P
89
0039
CCS MODEL 333 PACEMAKER SYSTEM
3
PMA Approval
P
88
0038
MODEL 9600 VERSION SC.11 PERSONALITY MODULE SOFT
3
PMA Approval
P
88
0086
SOLUS (R) MODELS 2002,2003,SYNCHRONY(R)2022,2023
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 9858 A SOFTWARE DISKETTES
3
PMA Approval
K
93
0770
MEDTRONIC MINIX & MINIX ST PULSE GENERATORS
3
Cleared 510(K)
K
92
3868
CCS MAESTRO II SERIES 200 CARDIAC PACEMAKER
3
Cleared 510(K)
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
88
0038
MEDA-MV PACING SYSTEM
3
PMA Approval
P
88
0038
MODEL 9600 AUX.INSTRUMENTS INTERFACE CABLE
3
PMA Approval
P
90
0070
CODEL 9600,4810,4510 5603,INTERFACE CABLE
3
PMA Approval
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 305 VDD PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 9858 SOFTWARE DISKETTES
3
PMA Approval
P
89
0039
CCS MODEL 300 PACEMAKER MAESTRO
3
PMA Approval
P
88
0086
SYNCHRONY(R)MODEL 2020T PULSE GEN.,& 3000 PROGRAMM
3
PMA Approval
P
88
0086
SOLUS(R) II MODELS 2006L,2006T,2007K,2007M/S PULSE
3
PMA Approval
P
88
0006
SENSOLOG (R) MODEL 3038 SOFTWARE MODIFICATION
3
PMA Approval
P
91
0020
RELAY(TM) MODELS 294-03 & 293-03 & DASH MODELS
3
PMA Approval
P
88
0086
SOLUS(TM) MODEL 2002L & SYNCHRONY II MODEL 2022L
3
PMA Approval
P
88
0006
SENSOLOG III MODEL 2033B & DIALOG II MODEL 2037B
3
PMA Approval
P
90
0070
MODEL 9600 PROG.,1250H GENERATOR SOFTWARE V4.10UE
3
PMA Approval
P
88
0038
META III MODEL 1206,1206E,1206M PACING SYSTEMS
3
PMA Approval
P
91
0020
RELAY(TM) MODELS 294-03 & 293-03 & DASH MODELS
3
PMA Approval
P
89
0003
MODEL 9760 PROGRAMMING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC (R) ELITE II PULSE GENERATOR
3
PMA Approval
P
88
0006
SENSOLOG (R) ALTERNATE PRODUCT TRAY
3
PMA Approval
P
88
0086
SYNCHRONY(R)ALTERNATE PRODUCT TRAY
3
PMA Approval
P
89
0003
MEDTRONIC MODELS ELITE,MINUET,& PRELUDE DR MODIF.
3
PMA Approval
K
92
0601
ASTRA T2, ASTRA T4, ASTRA T6
3
Cleared 510(K)
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC MODEL 9855 SOFTWARE CHANGE
3
PMA Approval
P
88
0086
SYNCHRONY(R) SOFTWARE CHANGE
3
PMA Approval
P
89
0039
CCS MODEL 333 PACEMAKER INTRO. 3 NEW MODELS
3
PMA Approval
P
91
0020
RELAY(TM) MODELS 294-03 & 293-03 & DASH MODELS
3
PMA Approval
P
89
0003
ELITE & PRELUDE DR PULSE GENERATORS
3
PMA Approval
P
88
0086
MODEL 3038 FUNCTION PACK FOR APS-II 3003 PROGRAMME
3
PMA Approval
P
88
0006
MODEL 3038 FUNCTION PACK FOR ASP-II 3003 PROGRAMME
3
PMA Approval
P
89
0003
MODEL 7074, 7075 AND 7077 ELITE(TM) PULSE GENERATO
3
PMA Approval
P
89
0003
MODEL 9760 PROGRAMMING SYSTEM
3
PMA Approval
P
89
0003
MODELS 7107,7108 MINUET PULSE GENERATORS
3
PMA Approval
K
92
0530
INTERMEDICS MODEL 366-15 VS 1 HEADER PLUG
3
Cleared 510(K)
K
92
0157
SCHNEIDER 8 FR. STAMINA(TM) GUIDING CATHETER
3
Cleared 510(K)
P
88
0038
META II MODEL 1204H CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0003
MODEL 7074, 7075 AND 7077 ELITE(TM) PULSE GENERATO
3
PMA Approval
K
91
4109
PIKOS 01 & PIKOS E 01
3
Cleared 510(K)
P
88
0006
SENSOLOG(R)III & DIALOG(R)II PULSE GENERATORS
3
PMA Approval
P
90
0070
META DDDR PACING SYSTEM
3
PMA Approval
P
88
0038
META II MODEL 1204 CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
3
PMA Approval
P
89
0039
POLYSAFE(TM) A-TRACK(TM) MODEL AT-332 ENDOCARDIAL
3
PMA Approval
P
88
0006
MODEL 3037A FUNCTION PACK
3
PMA Approval
P
88
0086
MODEL 3037A FUNCTION PACK
3
PMA Approval
P
89
0003
MODELS 7070,7071,7071M,SYNERGEST(TM)II PULSE GEN
3
PMA Approval
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0003
MODEL 9855 SOFTWARE SYSTEM
3
PMA Approval
K
90
5403
MODEL 340 SERIES UNIPOLAR & MODEL 5000B PROGRAMMER
3
Cleared 510(K)
P
88
0038
META II MODEL 1204 CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
3
PMA Approval
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
3
PMA Approval
P
88
0086
SENSOLOG 2020T, SESOLOG II 2022T, SOLUS 200T
3
PMA Approval
P
88
0086
APS-11 MODEL 3003 PROGRAMMER
3
PMA Approval
P
88
0006
APS-II MODEL 3003 PROGRAMMER
3
PMA Approval
P
88
0006
SENSOLOG III MODEL 2033B & DIALOG II MODEL 2037B
3
PMA Approval
K
91
3134
MODEL 4220
3
Cleared 510(K)
P
88
0086
SOLUS 2002,2003 & SYNCHRONY II 2022,2023 PULSE GEN
3
PMA Approval
P
89
0003
MODEL 9852 SOFTWARE SYSTEM
3
PMA Approval
K
91
2545
MODEL 4205 PULSE GENERATOR SURGICAL EXTEN CABLE
3
Cleared 510(K)
P
89
0003
SYNERGYST(TM) II MODELS 7070/7071 (M) (A)
3
PMA Approval
P
88
0086
SOLUS(TM) MODEL 2002L & SYNCHRONY II MODEL 2022L
3
PMA Approval
K
91
1122
8MM QUANTUM PULSE/SUPRIMA II PULSE GENERATORS
3
Cleared 510(K)
K
90
5824
MAESTRO(R) SERIES 100/200 CARDIAC S/CHAMB PACEMAKE
3
Cleared 510(K)
K
90
5087
TRIOS 02
3
Cleared 510(K)
P
89
0039
MAESTRO(R) MODEL 1006P PACEMAKER PROGRAMMER
3
PMA Approval
P
89
0003
MEDTRONIC ELITE(TM) MODELS 7074,7075,7076,& 7077
3
PMA Approval
P
88
0086
SYNCHRONY II MODEL 2023M/S & SOLAS MODEL 2003M/S
3
PMA Approval
P
88
0086
SYNCHRONY II MODEL 2023M/S & SOLAS MODEL 2003M/S
3
PMA Approval
K
90
3186
OPTIMA SERIES II MODEL 147B SINGLE CHAMBER PULSE
3
Cleared 510(K)
K
90
4941
MAESTRO SERIES 100/200 CARDIAC SINGLE CHAMBER PACE
3
Cleared 510(K)
K
90
4602
MEDTRONIC MODEL 5301B TEST CABLE
3
Cleared 510(K)
P
89
0003
MEDTRONIC SYNERGYST II MODEL 7070 PULSE GENERATOR
3
PMA Approval
K
90
4892
VACUUM BAKE CYCLE
3
Cleared 510(K)
P
88
0086
SYNCHRONY MODEL 2020T CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0003
MEDTRONIC SYNERGYST II MODEL 7070 PULSE GENERATOR
3
PMA Approval
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
3
PMA Approval
P
87
0054
MODEL K (UNIPOLAR) & M (BIPOLAR) ENDOCARDIAL LEADS
3
PMA Approval
K
90
3919
IMPLANTABLE PULSE DEVICES
3
Cleared 510(K)
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
3
PMA Approval
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
3
PMA Approval
P
89
0039
MASTRO SAVVI SERIES 300 VDD PACING SYSTEM
3
PMA Approval
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
3
PMA Approval
K
90
3081
NEOS (TM) 02 B PULSE GENERATOR
3
Cleared 510(K)
P
88
0038
META DDD MODEL 1230 PACER
3
PMA Approval
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
K
90
2134
MINIX, MINIX ST, NEW IC: L74
3
Cleared 510(K)
K
90
1535
MODIFIED MEDTRONIC CLASSIX MODEL 8438 PULSE GENE.
3
Cleared 510(K)
P
87
0054
MODEL Q (UNIPOLAR) & R (BIPOLAR) ENDOCARDIAL LEADS
3
PMA Approval
P
88
0086
SYNCHRONY II MODELS 2022T & 2023M - 2002T & 2003M
3
PMA Approval
P
88
0006
SENSOLOG III MODEL 2033B & DIALOG II MODEL 2037B
3
PMA Approval
P
88
0038
META MV MODEL 1202 & 1202 PULSE GENERATORS
3
PMA Approval
P
88
0086
MODEL 3033C FUNCTION PACT
3
PMA Approval
P
88
0086
MODEL 3003 PROGRAMMER MODEL 3036B FUNCTION PACK
3
PMA Approval
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
3
PMA Approval
K
90
0622
MODIFIED MODEL 5401B TEST CABLE
3
Cleared 510(K)
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
3
PMA Approval
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
3
PMA Approval
P
88
0038
META DDD MODEL 1230 PACER
3
PMA Approval
P
87
0054
KELVIN (R) PACING SYSTEM
3
PMA Approval
K
90
0461
OPUS MODEL 4021, VVI, 5MM UNIPOLAR
3
Cleared 510(K)
K
89
7116
OPTIMA MPT MODEL 5281E AND MODEL 5282E
3
Cleared 510(K)
P
88
0038
META DDD MODEL 1230 PACER
3
PMA Approval
K
89
6809
MEDTRONIC SPECTRAX SXT MODEL 8423M PULSE GENERATOR
3
Cleared 510(K)
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
P
89
0003
SYSNERGYST II PULSE GENERATOR MODELS 7070 & 7071
3
PMA Approval
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
3
PMA Approval
P
88
0086
SYNCHRONY II MODELS 2022T & 2023M - 2002T & 2003M
3
PMA Approval
K
89
6184
KALOS 05 PULSE GENERATOR
3
Cleared 510(K)
P
89
0003
SYSNERGYST II PULSE GENERATOR MODELS 7070 & 7071
3
PMA Approval
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
K
89
4239
NANOS
3
Cleared 510(K)
K
89
4240
NEOS 02
3
Cleared 510(K)
K
89
4494
LABELING CHANGES TO PULSE GENE. & PULSE GENE. LEAD
3
Cleared 510(K)
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
K
89
5495
ADD'L LABELING TO MINIX MODELS AND MINIX ST MODELS
3
Cleared 510(K)
K
89
4065
OPUS MODEL 4001
3
Cleared 510(K)
K
89
4267
OPUS MODELS 4033 AND 4034
3
Cleared 510(K)
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
P
88
0086
SYNCHRONY MODEL 2020T PULSE GENERATOR
3
PMA Approval
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
K
89
1231
OPTIMA MPT AND SPT PACEMAKERS
3
Cleared 510(K)
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
3
PMA Approval
K
89
4055
MINIX 8341M AND MINIX ST 8331M PULSE GENERATORS
3
Cleared 510(K)
K
88
4420
HOME BLOOD PRESSURE KIT, ANEROID
3
Cleared 510(K)
P
88
0086
ACCENT, IDENTITY, VERITY, VICTORY AND ZEPHYR PACEMAKERS
3
PMA Approval
K
89
4185
OPTIMA MPT SERIES III PACEMAKER, UNIPOLAR/BIPOLAR
3
Cleared 510(K)
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
P
88
0038
META-MV,PACING SYSTEM
3
PMA Approval
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
K
88
5267
VS-1 MODEL NUMBER 251K PULSE GENERATOR
3
Cleared 510(K)
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
K
89
0785
ASTRA T2, T3, T4, T6 PULSE GENERATORS NEW PACKAGE
3
Cleared 510(K)
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
3
PMA Approval
K
88
4733
AFP MODEL 262T PULSE GENERATOR
3
Cleared 510(K)
K
88
4411
OPTIMA MPT AND SPT PACEMAKERS
3
Cleared 510(K)
K
88
3037
UNILITH 3 MODELS 7580/7583/7680/7683
3
Cleared 510(K)
K
88
3750
VENTRALITH I
3
Cleared 510(K)
K
88
4215
MINIX 8340, 8341, 8342 MINIX-ST 8330, 8331
3
Cleared 510(K)
K
88
3755
MODIFIED SPECTRAX SX/SXT & PASYS/PASYS ST MODELS
3
Cleared 510(K)
K
88
2391
OPUS 3 PULSE GENERATORS MODELS 4003,4004,4023,4024
3
Cleared 510(K)
K
88
4023
MAESTRO(R) SERIES 100/200 SINGLE CHAMBER PACEMAKER
3
Cleared 510(K)
K
88
2427
CARDIAC PACE. OPUS 4000 MODELS 4043/4044/4063/4066
3
Cleared 510(K)
K
88
3087
PROLOG MP 658M PULSE GENERATOR
3
Cleared 510(K)
K
88
2474
OPUS PULSE GENERATORS MODELS 2001, 2003 AND 2004
3
Cleared 510(K)
K
88
2476
OPUS PULSE GENERATORS MODELS 3001, 3003 AND 3004
3
Cleared 510(K)
K
88
1904
CHANGE TO CATHODE POWDER SPECIFICATION
3
Cleared 510(K)
K
88
1837
OPTIMA MPT SERIES III PACEMAKER, 5281D AND 5282D
3
Cleared 510(K)
K
88
1711
VICOR MODELS 410B & 410D AND MODIFIED 410A PACEMA.
3
Cleared 510(K)
K
88
0898
MULTICOR AND PACEMAKERS
3
Cleared 510(K)
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
3
PMA Approval
K
88
0326
MAESTRO(R) MODELS 115, 118, 215 AND 218 PACEMAKERS
3
Cleared 510(K)
K
88
0422
MAESTRO(R) MODEL 119, SINGLE-CHAMBER PACEMAKER
3
Cleared 510(K)
K
88
0432
VICOR PACER, MODEL 410A
3
Cleared 510(K)
K
87
3158
MODIFIED MULTICOR AND OMNI-STANICOR PACEMAKERS
3
Cleared 510(K)
K
87
4158
CCS IMPLANTABLE MAESTRO(R) SERIES 100/200 PACEMAK.
3
Cleared 510(K)
K
87
4394
QUANTUM(R) MODELS 253-19V & 254-20V PULSE GENERA.
3
Cleared 510(K)
K
87
2766
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE GENERATORS
3
Cleared 510(K)
K
87
2779
PROLOG MP PULSE GENERATORS 658K AND 658T
3
Cleared 510(K)
K
87
3202
VICOR, MODEL 410A
3
Cleared 510(K)
K
87
3528
MODIFIED MODELS 253-19 & 254-20 QUANTUM GENERATORS
3
Cleared 510(K)
K
87
1992
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE GENERATORS
3
Cleared 510(K)
K
87
1866
MEDTRONIC CLASSIX MODELS 8436/8437/8438
3
Cleared 510(K)
K
87
1861
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE GENERATORS
3
Cleared 510(K)
K
87
0142
PINNACLE SR 8701 - UNIPOLAR & 8702 - BIPOLAR
3
Cleared 510(K)
K
86
5013
ASTRA T2, T4 AND T6
3
Cleared 510(K)
K
86
3898
MULTILITH 3 MODELS 1350, 3350, 1370, 3370
3
Cleared 510(K)
K
86
2226
DIALOG MODELS 748, 748K AND 748T PULSE GENERATORS
3
Cleared 510(K)
K
86
0036
EDP-20 PACEMAKER
3
Cleared 510(K)
K
86
2459
MODIFIED CIRCUIT BURN-IN PROCESS IMPLANTABLE PULSE
3
Cleared 510(K)
K
86
3878
TRIOS-M VS-1 PULSE GENERATOR
3
Cleared 510(K)
K
86
3879
NEOS-M VS-1 PULSE GENERATOR
3
Cleared 510(K)
K
86
3582
MODEL 725TH HANDHELD TRANSCEIVER (PROGRAMMER)
3
Cleared 510(K)
K
86
3417
CORDIS MULTICOR II MODEL 402D PACER
3
Cleared 510(K)
K
86
3365
MODIFICATION OF STERILITY CYCLE PARAMETERS
3
Cleared 510(K)
K
86
3418
MODEL 352-01 SILICONE RUBBER ISOLATION SLEEVE
3
Cleared 510(K)
K
86
2974
ALTERNATE PACKAGE CONFIG. FOR IMPLANT. PULSE GEN.
3
Cleared 510(K)
K
85
4790
CERYX PACEMAKER MODELS 114, 314 & 614
3
Cleared 510(K)
K
86
0921
NEOS VS-1, PULSE GENERATOR
3
Cleared 510(K)
K
86
0922
MIKROS, MIKROS VS-1, PULSE GENERATOR
3
Cleared 510(K)
K
86
0585
ASTRA T2, T3, T4 & T6 MULTIPROGRAM PULSE GENERATOR
3
Cleared 510(K)
K
85
3771
PINNACLE MULTI-PROGRAMMABLE PACING SYS
3
Cleared 510(K)
K
86
1719
MODIFIED MODELS 8320/8322/8329/8316/8317/8318
3
Cleared 510(K)
K
86
1422
PACESETTER/SIEMENS PULSE GENERA W/VS-1 HEAD CAVITY
3
Cleared 510(K)
K
86
2071
MODIFIED LABEL FOR/SPECTRAX SXT IMPLANT. PULSE GEN
3
Cleared 510(K)
K
86
2038
MODIFY LABEL/SPECTRAX S & SX IMPLANT PULSE GENER
3
Cleared 510(K)
K
86
2037
MODIFY LABEL/PASYS & MOD 8316/17/18 IMPLAN PUL GEN
3
Cleared 510(K)
K
86
0573
IMPLANT PROG PULSE GENERATOR, UNIPOLAR & BIPOLAR
3
Cleared 510(K)
K
86
1559
SERIES (T) PROGRAMMABLE CARDIAC PULSE GENERATORS
3
Cleared 510(K)
K
86
1140
PROGRAMALITH III PULSE GENERATOR
3
Cleared 510(K)
K
86
1009
BIPOLAR CARDIAC PACEMAKER, MODEL 110
3
Cleared 510(K)
K
85
2973
UNILITH 2 PULSE GENERATORS #7550, 7552, 7760, 7762
3
Cleared 510(K)
K
85
5147
MEDTRONIC MODELS 8316,8317,8318 PULSE GENERATORS
3
Cleared 510(K)
K
85
5081
PHOENIX MODELS 250/251 PULSE GENERATORS
3
Cleared 510(K)
K
85
4482
ALTERNATE STERILE PKG IMPLANTABLE PULSE GENERATORS
3
Cleared 510(K)
K
86
0466
MODEL 329D, SERIERS R BIOPOLAR CARDIAC PUL. GEN.
3
Cleared 510(K)
K
86
0202
MODEL 327D, SERIES R UNIPOLAR CARDIAC PULSE GENER.
3
Cleared 510(K)
K
85
3471
CCS IMPLANTABLE MAESTRO 106/206/210 CARDIAC PACEMA
3
Cleared 510(K)
K
85
3400
CCS IMPLANTABLE MAESTRO SERIES 200 CARDIAC PACEMAK
3
Cleared 510(K)
K
85
5171
TELEMETRY WAND MODEL
3
Cleared 510(K)
K
85
4560
IMPLANTABLE PROGRAMMABLE PULSE GENERATOR
3
Cleared 510(K)
K
85
2641
ORION 40 CARDIAC STIMULATOR & PMP 200 PROGRAMMER
3
Cleared 510(K)
K
85
1968
CORDIS MULTICOR ST, MODEL 350A
3
Cleared 510(K)
K
85
4195
PROGRAMALITH III MODELS 238 & 239
3
Cleared 510(K)
K
85
4919
BIPOLAR CARDIAC PULSE GENERATOR WITH TELEMETRY
3
Cleared 510(K)
K
85
4214
MULTICOR II 402B & 402C MULTIPROGRAM. CARDIAC PACE
3
Cleared 510(K)
K
85
4132
COOK PACEMAKER 332T, SERIES R BIPOLAR CARDIAC PULS
3
Cleared 510(K)
K
85
1365
SORIN BIOMEDICA ORION 30/A CARDIAC STIMULATOR & PM
3
Cleared 510(K)
K
85
2339
SUPRIMA MODEL 254-22
3
Cleared 510(K)
K
85
2340
SUPRIMA MODEL 254-24
3
Cleared 510(K)
K
85
4143
BATTERY INSULATOR FOR USE W/IMPLANTABLE PACEMAKERS
3
Cleared 510(K)
K
85
2748
CORDIS MODELS 336A,336B,337A & 334 CARDIAC PACEMAK
3
Cleared 510(K)
K
85
2688
MEDTRONICS MODELS 8320/8322/8329
3
Cleared 510(K)
K
85
3651
COOK PACEMAKER 33IT R UNIPOLAR CARDIAC PULSE GENER
3
Cleared 510(K)
K
85
3590
COOK PACEMAKER CORP. 327T, SERIES R UNIPOLAR CARDI
3
Cleared 510(K)
K
85
3058
NEOS - M ABP
3
Cleared 510(K)
K
85
3206
IMPLANT PROGRAM CARDIAC PULSE GEN W/MOD SET SCREW
3
Cleared 510(K)
K
85
3057
TRIOS - M
3
Cleared 510(K)
K
85
3425
CARIO-PACE DURAPULSE P101 COATED PULSE GENERATOR
3
Cleared 510(K)
K
85
2435
CCS IMPLANTABLE MAESTRO SERIES 100 CARDIAC PACEMA
3
Cleared 510(K)
K
85
3034
#335-01 SILIC RUB ISOLA SLEEVE FOR INT #281-03 SIZ
3
Cleared 510(K)
K
85
3017
ELA MEDICAL CARDIAC PACEMAKERS MULTIL 2 #1251&2251
3
Cleared 510(K)
K
85
2431
SUPRIMA II MODEL 254-26
3
Cleared 510(K)
K
85
2430
SUPRIMA II MODEL 253-23
3
Cleared 510(K)
K
85
2432
SUPRIMA II MODEL 254-28
3
Cleared 510(K)
K
85
1420
MULTICOR S, MODELS 330A/331A
3
Cleared 510(K)
K
84
4360
CORDIS MULTICOR S 330A & 331A CARDIAC PACEMAKERS
3
Cleared 510(K)
K
85
1419
MULTICOR GAMMA 402 SERIES PACER
3
Cleared 510(K)
K
85
1418
OMNI-ATRICOR MODEL 308A
3
Cleared 510(K)
K
85
1417
MULTICOR GAMMA MODELS 336/337
3
Cleared 510(K)
K
85
1416
STANICOR GAMMA 333B/334A
3
Cleared 510(K)
K
85
1861
PROGRAMALITH III MODEL 249 PULSE GENERATOR
3
Cleared 510(K)
K
85
1699
COOK PACEMAKER CORP. 332T BIPOLAR CARDIAC PULSE GE
3
Cleared 510(K)
K
85
0464
PROGRAMALITH III 240 PULSE GENERATOR
3
Cleared 510(K)
K
84
4842
NEOS-LP PULSE GENERATOR
3
Cleared 510(K)
K
84
4841
KALOS-04 PULSE GENERATOR
3
Cleared 510(K)
K
84
4812
NEOS - PULSE GENERATOR
3
Cleared 510(K)
K
84
4794
LEPTOS PULSE GENERATOR
3
Cleared 510(K)
K
84
4795
NEOS-M PULSE GENERATOR
3
Cleared 510(K)
K
85
1081
IMPLANTABLE PROGRAM-CARDIAC PULSE GEN-OPTIMA MP II
3
Cleared 510(K)
K
85
0252
QMPLANTABLE PROGRAM. CARDIAC PULSE GEN. W/TELEMETR
3
Cleared 510(K)
K
85
0651
PROGRAMALITH III-3 MODEL 231 PULSE GENERATOR
3
Cleared 510(K)
K
85
0384
CCS IMPLANTABLE MAESTRO SERIES 100-HEART PACEMAKER
3
Cleared 510(K)
K
85
0656
COOK 331T UNIPOLAR CARDIAC PULSE GENERATOR W/TELEM
3
Cleared 510(K)
K
84
2051
EKG TRANSMITTER MODEL 5134
3
Cleared 510(K)
K
84
4958
MEDTRONIC MODELS 8432/8433/8434 - PACEMAKER PULSE
3
Cleared 510(K)
K
84
4957
MEDTRONIC MODEL 8436 -PACEMAKER PULSE GENERATOR
3
Cleared 510(K)
K
84
4793
SUPRIMA 253-21 IMPLANTABLE PULSE GENERATOR
3
Cleared 510(K)
K
84
4334
VIVALITH II 301 PULSE GENERATOR
3
Cleared 510(K)
K
84
2193
MULTILITH PULSE GENERATORS, 1141 & 2141
3
Cleared 510(K)
K
84
1230
PULSE GENERATOR 686, 686B 686L
3
Cleared 510(K)
K
84
1232
PULSE GENERATOR 696, 696B & 696L
3
Cleared 510(K)
K
84
1225
PULSE GENERATOR 689, 689B & 689L
3
Cleared 510(K)
K
84
2220
MULTILITH 2 PULSE GENERATOR 1141 & 2141
3
Cleared 510(K)
K
84
2473
IMPLANTABLE PROGRAMMABLE PULSE GENERAT
3
Cleared 510(K)
K
84
3837
MEDTRONIC 5984-5984LP-5985
3
Cleared 510(K)
K
84
2394
ASTRA 2, ASTRA 3, 4 & 6
3
Cleared 510(K)
K
84
3089
MEDTRONIC 8437/8438
3
Cleared 510(K)
K
84
1633
NEOS LP
3
Cleared 510(K)
K
84
1635
LEPTOS
3
Cleared 510(K)
K
84
0748
LITHIUM PACEMAKER 811-811L & 811XL
3
Cleared 510(K)
K
84
1983
COOK PACEMAKER 216 BIPOLAR CARDIAC -
3
Cleared 510(K)
K
84
1928
COOK PACEMAKER 215 UNIPOLAR CARDIAC-
3
Cleared 510(K)
K
84
2081
COOK PACEMAKER CORP. 115 UNIPOLAR CARDI
3
Cleared 510(K)
K
84
1233
PULSE GENERATOR 678L
3
Cleared 510(K)
K
84
1231
PULSE GENERATOR 688B & 688L
3
Cleared 510(K)
K
84
1226
PULSE GENERATOR 728, 728B & 728L
3
Cleared 510(K)
K
84
1228
PULSE GENERATOR 718B & 718L
3
Cleared 510(K)
K
84
1950
PULSE GENERATOR KALOS-04
3
Cleared 510(K)
K
84
1636
NEOS M
3
Cleared 510(K)
K
84
1229
PULSE GENERATOR 698, 698B & 698L
3
Cleared 510(K)
K
84
1404
PRIMA 236-02 NONPROGRAMMABLE CARDIAC
3
Cleared 510(K)
K
84
1073
QUANTUM, UNIPOLAR, MULTI-PROGRAMMABLE
3
Cleared 510(K)
K
84
1075
CARCIAC PULSE GENERATOR 254-20
3
Cleared 510(K)
K
84
1074
CARDIAC PULSE GENERATOR 254-18
3
Cleared 510(K)
K
84
0737
IMPLANTABLE PROGRAMMABLE PULSE GENER
3
Cleared 510(K)
K
84
0701
PACEMAKER 147 VVI-THE OPTINIA
3
Cleared 510(K)
K
83
3428
IMPLANTABLE UNIPOLAR CARDIAC PULSE GEN
3
Cleared 510(K)
K
83
3427
IMPLANTABLE BIPOLAR CARDIAC PULSE GEN
3
Cleared 510(K)
K
83
3519
PULSE GENERATOR MODEL 688
3
Cleared 510(K)
K
83
4096
IMPLANTABLE PULSE GENERATOR
3
Cleared 510(K)
K
83
3798
OPTIMA MDT PULSE GENERATOR W/TELEMETRY
3
Cleared 510(K)
K
83
2914
PRIMA-UNIPOLAR CARDIAC PULSE GENERAT
3
Cleared 510(K)
K
83
3199
SILICONE RUBBER ISOLATION SLEEVE 350-01
3
Cleared 510(K)
K
83
3198
SILICONE RUBBER ISOLATION SLEEVE 351-01
3
Cleared 510(K)
K
83
1860
GENERATOR, PULSE, PACEMAKER #532
3
Cleared 510(K)
K
83
1859
PACEMAKER PROGRAMMER #2032
3
Cleared 510(K)
K
83
1633
QUANTUM BIPOLAR CARDIAC PULSE GENERATOR
3
Cleared 510(K)
K
83
2893
MODEL 329T PROGRAMMABLE, BIPOLAR CARDI
3
Cleared 510(K)
K
83
1771
IMPLANTABLE PROGRAM. CARDIAC PULSE GEN
3
Cleared 510(K)
K
83
2052
MODEL 327T UNIPOLAR CARDIAC PULSE GEN
3
Cleared 510(K)
K
83
1216
COMMAND ULTRA II
3
Cleared 510(K)
K
83
1161
COMMAND ULTRA I
3
Cleared 510(K)
K
83
0344
SIEMENS-ELMA PULSE GENERATOR #718
3
Cleared 510(K)
K
83
0862
NEDS-01 & EPR-500
3
Cleared 510(K)
K
83
0390
IMPLANTABLE BIPOLAR CARDIAC PULSE GEN
3
Cleared 510(K)
K
82
3878
IMPLANTABLE PACEMAKER PULSE GEN, MODELS 241 & 242
3
Cleared 510(K)
K
83
0401
UNILITH PULSE GENERATOR VVI #7542
3
Cleared 510(K)
K
83
0382
COMMAND ULTRA II
3
Cleared 510(K)
K
82
3831
MEDTRONIC MODELS 59401 5941
3
Cleared 510(K)
K
82
3863
CYBERLITH IX QUANTUM-UNIPOLAR CARDIAC
3
Cleared 510(K)
K
82
3559
AFP PULSE GENERATOR
3
Cleared 510(K)
K
82
2639
AFP SYSTEM PULSE GENERATOR MODEL 261/262
3
Cleared 510(K)
K
82
3678
TELEMETRY DECODER #540-02
3
Cleared 510(K)
K
82
3371
DURAPULSE
3
Cleared 510(K)
K
82
2791
CORATOMIC #VX5-105 & VX5-205 PULSE GEN.
3
Cleared 510(K)
K
82
2907
KALOS-03 BIPOLAR
3
Cleared 510(K)
K
82
2904
MODEL 325D UNIPOLAR CARDIAC PULSE GEN
3
Cleared 510(K)
K
82
2652
JAIN INSULATING BOOT MODEL 225B
3
Cleared 510(K)
K
82
2297
ENERTRAX MODEL 7100E
3
Cleared 510(K)
K
82
2309
COMMAND NP
3
Cleared 510(K)
K
82
2147
MEDTRONIC ENERTRAX MODEL 7100
3
Cleared 510(K)
K
82
0939
C-101-P
3
Cleared 510(K)
K
82
1033
CORATOMIC MODEL OVALITH-920
3
Cleared 510(K)
K
82
1014
CORATOMIC MODEL OVALITH 920BP
3
Cleared 510(K)
K
82
1147
COOK #326T PROGRAM/TELEMETRY BIPOLAR
3
Cleared 510(K)
K
82
1073
PULSE GENERATOR
3
Cleared 510(K)
K
82
1003
PROGRAMMALITH II, #225 & 226
3
Cleared 510(K)
K
82
0657
PULSE GENERATOR 678 B
3
Cleared 510(K)
K
82
0853
QUANTUM MODELS 253-09, 254-09 254-10
3
Cleared 510(K)
K
82
0774
IMPLANTABLE, MULTIPROGRAMMABLE
3
Cleared 510(K)
K
82
0356
MULTICOR (GAMMA) 402 CARDIAC PACER
3
Cleared 510(K)
K
82
0231
COMMAND ULTRA I
3
Cleared 510(K)
K
81
3246
MEDICAL MULTILITH PULSE GENERA-1140
3
Cleared 510(K)
K
81
3576
SIEMENS-ELEMA PULSE GENERATOR 659
3
Cleared 510(K)
K
81
3534
COMMAND P5
3
Cleared 510(K)
K
81
3079
BIPOLAR OPTIMA MP #255
3
Cleared 510(K)
K
81
2610
SIEMENS-ELEMA PULSE GENERATOR 668 B
3
Cleared 510(K)
K
81
3150
DIRECTIONAL BOOT
3
Cleared 510(K)
K
81
3101
CARDIOBEEPER MEMORY MONITOR
3
Cleared 510(K)
K
81
2464
SYNTHEMED PULSE GENERATOR VVI MODEL 1000
3
Cleared 510(K)
K
81
2832
MODEL 325C UNIPOLAR CARDIAC PULSE GEN.
3
Cleared 510(K)
K
81
2790
IMPLANTABLE VENTRICULAR-INHIBITED CARDI
3
Cleared 510(K)
K
81
2358
MODEL 325T PROGRAMMABLE PULSE GENERATOR
3
Cleared 510(K)
K
81
2218
KALOS-03
3
Cleared 510(K)
K
81
2580
MEDTRONIC MODEL 2409
3
Cleared 510(K)
K
80
1339
TELEMETRY DECODER
3
Cleared 510(K)
K
80
1337
CYBERLITH IX IMPLANTABLE PULSE GENERATOR
3
Cleared 510(K)
K
81
2096
MEDTRONIC ENERTRAX MODEL 7100
3
Cleared 510(K)
K
81
2153
MEDTRONIC SPECTRAX
3
Cleared 510(K)
K
81
1402
COMMAND P5(BIPOLAR PULSE GENERATOR)
3
Cleared 510(K)
K
81
1768
CORATOMIC MODEL OVALITH-920BP
3
Cleared 510(K)
K
81
1691
CORDIS OMNI-ARTICOR CARDIAC PACER #308
3
Cleared 510(K)
K
81
0887
ELA MEDICAL UNILITH 7540 PULSE GENERATOR
3
Cleared 510(K)
K
81
1350
UNIPOLAR SPECTRAX IMPL. PULSE GENERAT.
3
Cleared 510(K)
K
81
0884
#325 PROGRAMMABLE CARD. PULSE GENERATOR
3
Cleared 510(K)
K
81
0885
#326 PROGRAMMABLE CARD. PULSE GENERATOR
3
Cleared 510(K)
K
81
0489
MULTILITH PULSE GENERATOR #1140
3
Cleared 510(K)
K
81
0142
ELA MEDICAL UNILITH PULSE GENERATOR
3
Cleared 510(K)
K
81
1221
INTERMEDICS CYBERLITH BIPOLAR CARDIAC
3
Cleared 510(K)
K
81
1123
MEDTRONIC PULSE GENERATOR
3
Cleared 510(K)
K
81
0677
MODELS 5976/5977 PACEMAKER PULSE GENER
3
Cleared 510(K)
K
81
0808
CORATOMIC MODEL OVALITH-920
3
Cleared 510(K)
K
81
0734
MODELS 8420 THRU 8423 PACEMAKER GENER
3
Cleared 510(K)
K
81
1066
MODEL 230-06 CYBERLITH TM I BIPOLAR IN
3
Cleared 510(K)
K
81
0800
MODEL 230-05 CYBERLITH I BIPOL. PULSE G.
3
Cleared 510(K)
K
81
0752
THINLITH III UNIPOLAR CARDIAC PULSE GEN.
3
Cleared 510(K)
K
81
0901
INSULATIVE COATING FOR CARD. PULSE GEN
3
Cleared 510(K)
K
81
0603
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE
3
Cleared 510(K)
K
81
0383
INTERMEDICS CYBERLITH I BIOPOLAR CARDI
3
Cleared 510(K)
K
81
0385
CYBERLITH I PULSE GENERATOR MODEL 253-04
3
Cleared 510(K)
K
81
0386
THINLITH II PULSE GNEERATOR MODEL 227-05
3
Cleared 510(K)
K
81
0410
STERILE PACKAGING
3
Cleared 510(K)
K
81
0121
UNIFOCAL 3
3
Cleared 510(K)
K
80
1584
MULTI-PROGRAMMABLE PACEMAKER & PROGRMR.
3
Cleared 510(K)
K
80
2864
SIEMENS-ELEMA PULSE GENERATOR 678
3
Cleared 510(K)
K
81
0036
SIEMENS-ELEMA MYOCARDIAL LEAD
3
Cleared 510(K)
K
80
3197
IMPL. PROGRAMMABLE BIPOLAR CARD.GEN.#274
3
Cleared 510(K)
K
80
1338
CYBERLITH PROGRAMMER
3
Cleared 510(K)
K
80
3035
MICROTHIN-PII BIPOLAR PULSE GEN. #0621
3
Cleared 510(K)
K
80
3034
MICROTHIN-PII BIPOLAR PULSE GEN. #0623
3
Cleared 510(K)
K
80
2353
MICRO THIN-PII, #0523
3
Cleared 510(K)
K
80
2352
MICRO THIN-DII, #0521
3
Cleared 510(K)
K
80
0746
UNIFOCAL VP, MODELS 7501 AND 7502
3
Cleared 510(K)
K
80
1324
SIEMENS-ELEMA PULSE GENERATOR 668
3
Cleared 510(K)
K
80
2588
MODEL 3003 UNIPOLAR DEMAND CARDIAC GEN.
3
Cleared 510(K)
K
79
2609
LITHICRON 0520 P-SYNCHRONEOUS PULSE GEN.
3
Cleared 510(K)
K
80
2410
MICROTHIN-PI BIPOLAR PULSE GENERATOR
3
Cleared 510(K)
K
80
2409
MICROTHIN-DI BIPOLAR PULSE GENERATOR
3
Cleared 510(K)
K
80
1640
SORIN PULSE GENERATOR, MODEL #LIT-214
3
Cleared 510(K)
K
80
2028
IMPLANTABLE VENTRICULAR-INHIB. C.P. GEN
3
Cleared 510(K)
K
80
1978
PROGRAMALITH #'S 221, 222, 221A & 222A
3
Cleared 510(K)
K
80
0379
BIFOCAL 2 8200 SERIES (A,B C,D)
3
Cleared 510(K)
K
80
0793
IMPLANTABLE PROGRAM. CARDIAC PACEMAKER
3
Cleared 510(K)
K
80
1508
SIEMENS-ELEMA PULSE GENERATOR 625
3
Cleared 510(K)
K
80
1910
INSULATING SHEATH
3
Cleared 510(K)
K
80
2040
BATTERY FOR #229-01 PULSE GENERATOR
3
Cleared 510(K)
K
80
1806
EXTERNAL SILASTIC BOOT FOR CARDIAC PULSE
3
Cleared 510(K)
K
80
0226
MEDTRONIC MODEL 2409
3
Cleared 510(K)
K
80
1763
VIVALITH 5, - MDL-201A & TDL-201A
3
Cleared 510(K)
K
80
1647
SONACOLOR 6100
3
Cleared 510(K)
K
80
1450
INTERMEDICS THIN LITH IV SERIES UNIPOLAR
3
Cleared 510(K)
K
80
1106
MULTICOR (GAMMA) MODEL 336 & MODEL 337
3
Cleared 510(K)
K
80
1241
UNIPOLAR PROGRAMMABLE LITHIUM CARD. GEN.
3
Cleared 510(K)
K
80
1122
MICROTHIN-D1 (MOD. 0620)
3
Cleared 510(K)
K
80
1121
MICROTHIN-P1 (MOD. 0622)
3
Cleared 510(K)
K
80
0837
PROGRAMMABLE BIPOLAR CARDIAC GENERATOR
3
Cleared 510(K)
K
80
0069
MEDTRONIC MODELS 5966/5967, ETC.
3
Cleared 510(K)
K
80
0838
ARCOLITH 3022&ARCOLITH 3023 CARDIAC GEN.
3
Cleared 510(K)
K
80
0285
MODEL 5985 PACEMAKER PULSE GENERATOR
3
Cleared 510(K)
K
80
0387
PULSE GENERATORS MODELS 657 & 677
3
Cleared 510(K)
K
80
0895
MODEL 253-11 CYBERLITH PULSE GENERATOR
3
Cleared 510(K)
K
80
0644
CYBERLITH IMPLANTABLE PULSE GEN. #253-02
3
Cleared 510(K)
K
80
0375
NOMOS-01 PULSE GENERATOR
3
Cleared 510(K)
K
80
0645
CYBERLITH IMPLANTABLE PULSE GEN. #253-04
3
Cleared 510(K)
K
80
0573
IMPLANTABLE PROGRAMMABLE BIPOLAR CARDIAC
3
Cleared 510(K)
K
80
0326
ARCOLITH 3021-CARDIAC PULSE GENERATOR
3
Cleared 510(K)
K
80
0194
OVALITH P-BP BIPOLAR CARDIAC PACEMAKER
3
Cleared 510(K)
K
79
2526
PULSE GENERATOR, MODEL NO. LIT 222
3
Cleared 510(K)
K
79
2565
SORIN PULSE GENERATOR MODEL # LIT 214 H
3
Cleared 510(K)
K
80
0026
MICROTHIN-DI
3
Cleared 510(K)
K
80
0027
MICROTHIN-PI
3
Cleared 510(K)
K
80
0030
IMPLANTABLE BIPOLAR CARDIAC PULSE GEN.
3
Cleared 510(K)
K
79
2519
IMPLANTABLE PROGRAMMABLE UNIPOLAR
3
Cleared 510(K)
K
79
2299
ARCOLITH 3020-CARDIAC PULSE GENERATOR
3
Cleared 510(K)
K
79
2216
ARCOLITH 2100-CARDIAC PULSE GENERATOR
3
Cleared 510(K)
K
79
1920
CARDIAC PACEMAKER P4000 SER. & P1000
3
Cleared 510(K)
K
79
2232
UNIFOCAL 3-2 MODELS UNIPOLAR & BIPOLAR
3
Cleared 510(K)
K
79
2199
UNIFOCAL 2-UNIPOLAR & BIPOLAR
3
Cleared 510(K)
K
79
1955
UNIFOCAL 1 UNIPOLAR DEMAND R WAVE
3
Cleared 510(K)
K
79
1316
MEDTRONIC MODELS 5984/5985
3
Cleared 510(K)
K
79
1921
CARDIAC PACEMAKER C4000, C1000 SER.
3
Cleared 510(K)
K
79
2052
IMPLANTABLE PROGRAMMABLE UNIPOLAR CARD
3
Cleared 510(K)
K
79
1783
OMNI-STANICOR (THETA) MOD 237A
3
Cleared 510(K)
K
79
0792
PULSE GENERATOR MODEL 637
3
Cleared 510(K)
K
79
1784
CORDIS BIPOLAR PACER CONNECTOR SYSTEM
3
Cleared 510(K)
K
79
0068
PULSE GENERATORS, MODELS 5983, 5989
3
Cleared 510(K)
K
79
1715
ARCOLITH 2000
3
Cleared 510(K)
K
79
1727
IMPLANTABLE VENTRICULAR-INHIBITED
3
Cleared 510(K)
K
79
1751
EDWARDS PACEMAKER 30 UNIPOLAR GENERATOR
3
Cleared 510(K)
K
79
1181
PROGRAMMER, MEDTRONIC MODEL 5984/5985
3
Cleared 510(K)
K
79
0873
MODEL 221 PROGRAMALITH PULSE GENERATOR
3
Cleared 510(K)
K
79
1568
IMPLANTABLE PULSE GENERATOR PACEMAKERS
3
Cleared 510(K)
K
79
1379
MODEL 228-02 THINLITH II PACEMAKER, BIPO
3
Cleared 510(K)
K
79
1678
LITHICRON II 0403 IMPLANTABLE PACEMAKER
3
Cleared 510(K)
K
79
1417
IMPLANTABLE PULSE GENERATOR PACEMAKER
3
Cleared 510(K)
K
79
1225
BJORK-SHILEY AORTIC GRAFT VALVE PROSTH
3
Cleared 510(K)
K
79
1095
LITHICRON MODEL 0401, PACEMAKER
3
Cleared 510(K)
K
79
0428
MDL-201A & T DL-201A PULSE GENERATOR
3
Cleared 510(K)
K
79
0141
PULSE GENERATOR, R WAVE DEMAND
3
Cleared 510(K)
K
79
1147
ARCO PROGAMMABLE PACEMAKER SYSTEM
3
Cleared 510(K)
K
79
1219
UNILITH PULSE GENERATOR
3
Cleared 510(K)
K
79
0446
OVALITH-300
3
Cleared 510(K)
K
78
2162
BATTERY CHARGER, 171 PACEMAKER
3
Cleared 510(K)
K
78
2161
PULSE GENERATOR, MODEL 171
3
Cleared 510(K)
K
79
1165
ARCOLITH 4000
3
Cleared 510(K)
K
79
0670
PULSE GENERATOR MODEL 629
3
Cleared 510(K)
K
79
1093
MODELS 2411/2418 VENTRICULAR-INHIBITED
3
Cleared 510(K)
K
79
0666
VITALITH S 3000 SERIES
3
Cleared 510(K)
K
79
0867
CARDIAC PULSE GENERATOR, 16 SERIES
3
Cleared 510(K)
K
79
0868
GENERATOR, 16 SERIES, MODIFIED TOP CAP
3
Cleared 510(K)
K
79
0690
OMNI-STANICOR-(THETA) MODEL 217
3
Cleared 510(K)
K
79
0562
PULSE GENERATOR MODEL 61 AND 128
3
Cleared 510(K)
K
79
0452
28 UNIPOLAR AND BIPOLAR PULSE GENERATORS
3
Cleared 510(K)
K
79
0764
PACEMAKERS WITHOUT SILASTIC COATING
3
Cleared 510(K)
K
78
1973
CARDIOPHONE
3
Cleared 510(K)
K
79
0432
MICROLITH MODELS 505;605;507;607;703;803
3
Cleared 510(K)
K
79
0566
PACEMAKER, OVALITH-D CARDIAC
3
Cleared 510(K)
K
79
0276
MINILITH AND MICROLITH
3
Cleared 510(K)
K
79
0014
BIPOLAR, STANICOR LAMBDA MODEL 236,235
3
Cleared 510(K)
K
78
2149
PULSE GENERATOR, IMPLANTABLE CARDIAC
3
Cleared 510(K)
K
79
0101
ISOLATION SLEEVE, MODEL 346-01
3
Cleared 510(K)
K
79
0100
ISOLATION SLEEVE, MODEL 348-01
3
Cleared 510(K)
K
79
0099
ISOLATION SLEEVE, MODEL 347-01
3
Cleared 510(K)
K
79
0098
ISOLATION SLEEVE, MODEL 349-01
3
Cleared 510(K)
K
78
2146
PACEMAKER, MODEL DDP ELECTRONIC CIRCUIT
3
Cleared 510(K)
K
78
2023
MICROLITH A MODEL 803
3
Cleared 510(K)
K
78
2022
MICROLITH A MODEL 703
3
Cleared 510(K)
K
78
0430
LITHICRON F PROGRAMMABLE PULSE GEN
3
Cleared 510(K)
K
78
1835
PULSTRON MODEL 100
3
Cleared 510(K)
K
78
1738
PACEMAKER, MODEL 229-01
3
Cleared 510(K)
K
78
0897
GENERATOR, PULSE, SORIN MODEL DL-1
3
Cleared 510(K)
K
78
1377
OVALITH 10BP
3
Cleared 510(K)
K
78
1252
GENERATOR, PULSE, MODEL 5997
3
Cleared 510(K)
K
78
1208
GENERATORS, PULSE, MODELS 5988/5989
3
Cleared 510(K)
K
78
0776
ARCOBIOLITH PACEMAKER MODEL
3
Cleared 510(K)
K
78
1424
GENERATORS: UDL-201B, BDL-201B, MDL-201B
3
Cleared 510(K)
K
78
0940
GENERATOR, PULSE, MODEL 160B
3
Cleared 510(K)
K
77
2226
PACEMAKER, MODEL 225 & 227
3
Cleared 510(K)
K
78
1426
CARDIAL PULSE GENERATORS
3
Cleared 510(K)
K
78
1178
PULSE GENERATOR MODEL 208
3
Cleared 510(K)
K
78
1090
GENERATOR, CARDIAC PULSE, 250B
3
Cleared 510(K)
K
78
1168
GENERATOR, PULSE, PACEMAKER
3
Cleared 510(K)
K
78
0809
GENERATOR, PULSE MODELS 5920/5921
3
Cleared 510(K)
K
78
0741
GENERATOR, PULSE, DEMAND, MODEL 5996
3
Cleared 510(K)
K
78
1042
PROLITH 23S PACEMAKER
3
Cleared 510(K)
K
78
0781
STILITH CARDIAC PACEMAKERS-M. 60 & 120
3
Cleared 510(K)
K
78
0561
VENTRICULAR INHIBITED PULSE GENERATOR
3
Cleared 510(K)
K
78
0420
GENERATOR, PULSE, CARDIAC, IMPLANTABLE
3
Cleared 510(K)
K
78
0421
GENERATOR, PULSE, CARDIAC, IMPLANTABLE
3
Cleared 510(K)
K
78
0780
MICROPULSE 22S PACEMAKER
3
Cleared 510(K)
K
78
0453
STANICOR THETA MODEL 221 CARDIAC PACER
3
Cleared 510(K)
K
78
0327
GENERATORS, ATRIAL INHIBITED PULSE
3
Cleared 510(K)
K
78
0777
BAGS, PLASTIC, STERILE FOR GENERATORS
3
Cleared 510(K)
K
78
0437
PACEMAKER, MODEL 252, C-MOS
3
Cleared 510(K)
K
78
0238
PACEMAKER, PROLITH 23U. PULSE GENERATOR
3
Cleared 510(K)
K
78
0113
CARDIAC PULSE GENERATOR, MODEL 160B
3
Cleared 510(K)
K
78
0091
MICROPULSE 22U
3
Cleared 510(K)
K
78
0066
CARDIAC PACER, MODEL 208
3
Cleared 510(K)
K
77
2239
PULSE GENERATOR, BIPOLAR, PROGRAMMABLE
3
Cleared 510(K)
K
77
2238
PULSE GENERATOR, UNIPOLAR, PROGRAMABLE
3
Cleared 510(K)
K
77
2241
PULSE GENERATOR, BIPOLAR, DEMAND
3
Cleared 510(K)
K
77
2240
PULSE GENERATOR, UNIPOLAR, DEMAND
3
Cleared 510(K)
K
77
2050
TDL-100 B
3
Cleared 510(K)
K
77
2051
MDL-201
3
Cleared 510(K)
K
78
0061
PULSE GENERATORS, MODELS 5972/5973
3
Cleared 510(K)
K
77
2357
PULSE GENERATORS
3
Cleared 510(K)
K
77
1786
CARDIAC PULSE GENERATORS 5982/5983
3
Cleared 510(K)
K
77
1770
XYREL-RA MODELS 5994/5995
3
Cleared 510(K)
K
77
2202
PULSE GENERATOR, A-V SEQ.
3
Cleared 510(K)
K
77
2010
CARDIAC PACEMAKER C2001
3
Cleared 510(K)
K
77
2009
CARDIAC PACEMAKER S6001
3
Cleared 510(K)
K
77
2057
BIPOLAR PACEMAKER MODEL 224
3
Cleared 510(K)
K
77
2026
CARDIAC PULSE GENERATOR, MODEL 150L
3
Cleared 510(K)
K
77
1992
L-501 CARDIAC PACEMAKER
3
Cleared 510(K)
K
77
1987
MICROPULSE 26U PULSE GENERATOR
3
Cleared 510(K)
K
77
1670
IMPLANTED PACEMAKER PLUSE GENERATOR
3
Cleared 510(K)
K
77
1626
PACEMAKER MODEL 251
3
Cleared 510(K)
K
77
1538
LITHICRON MODEL 3-70C-B PULSE GENERATOR
3
Cleared 510(K)
K
77
1262
PACEMAKER & CARDIAC LEAD, BIPOLAR
3
Cleared 510(K)
K
77
0951
CARDIAC PACERS W/NARROW PULSE WIDTH
3
Cleared 510(K)
K
77
0881
GENERATOR, PULSE, BIPOLAR 3608
3
Cleared 510(K)
K
77
0880
GENERATOR, PULSE, UNIPOLAR, #508
3
Cleared 510(K)
K
77
0716
GENERATOR, PULSE, UNIPOLAR, MODEL #504
3
Cleared 510(K)
K
77
0661
GENERATOR, PULSE, IMPLANTABLE
3
Cleared 510(K)
K
77
0657
GENERATOR, PULSE, CARDIAC 2LU
3
Cleared 510(K)
K
77
0656
GENERATOR, PULSE, CARDIAC 20U
3
Cleared 510(K)
K
77
0715
GENERATOR, PULSE, BIPOLAR, MODEL #604
3
Cleared 510(K)
K
77
0507
PULSE GENERATOR, LITKICRON MODEL 3-70H
3
Cleared 510(K)
K
77
0419
CENTURION
3
Cleared 510(K)
K
77
0559
C-L0L CARDIAC PACEMAKER
3
Cleared 510(K)
K
77
0212
PROLITH MODEL 21S CARDIAC PULSE GEN.
3
Cleared 510(K)
K
77
0211
MICROPULSE MODEL 20S
3
Cleared 510(K)
K
77
0328
PACEMAKER, ANTRIO-VENTRICULAR SEQ.
3
Cleared 510(K)
K
77
0005
PACEMAKER 208S
3
Cleared 510(K)
K
77
0198
BIPOLAR ASYNCHRONOUS PULSE GENERATOR
3
Cleared 510(K)
K
77
0197
UNIPOLAR, ASYNCHRONOUS PULSE GENERATOR
3
Cleared 510(K)
K
77
0135
LEAD MODIFICATION
3
Cleared 510(K)
K
76
1143
LITHIUM IODIDE BATTERY PACEMAKER (#201)
3
Cleared 510(K)
K
76
1237
ELEC. CIR. PACE. MO. LI-2,LI-3,LI-4,LI-5
3
Cleared 510(K)
K
76
0670
PACEMAKERS, VITATRONS (SERIES 2000)
3
Cleared 510(K)
K
76
0669
PACEMAKERS, VITATRON'S
3
Cleared 510(K)
K
76
0671
PACEMAKERS, VITATRONS (SERIES 3000)
3
Cleared 510(K)
K
76
0757
MODEL 100 CARDIAC PACEMAKER
3
Cleared 510(K)
DXZ
Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene
2
Product Code
DYE
Replacement Heart-Valve
3
Product Code
DYF
Prosthesis, Vascular Graft, Of Less Then 6mm Diameter
2
Product Code
KFJ
Materials, Repair Or Replacement, Pacemaker
3
Product Code
KRD
Device, Vascular, For Promoting Embolization
2
Product Code
KRE
Analyzer, Pacemaker Generator Function, Indirect
2
Product Code
KRF
Charger, Pacemaker
1
Product Code
KRG
Programmer, Pacemaker
3
Product Code
KRH
Ring, Annuloplasty
2
Product Code
LDF
Electrode, Pacemaker, Temporary
2
Product Code
MAB
Marker, Cardiopulmonary Bypass (Vein Marker)
2
Product Code
MAL
Graft, Vascular, Synthetic/Biologic Composite
2
Product Code
MFX
Vessel Guard Or Cover, To Facilitate Revision Surgeries
2
Product Code
MOP
Rotator, Prosthetic Heart Valve
1
Product Code
MZY
Graft, Vascular, Stainless Steel Tunneler
2
Product Code
NHW
Electrode, Pacing And Cardioversion, Temporary, Epicardial
2
Product Code
NKO
System, Balloon, Intra-Aortic And Control, Reprocessed
3
Product Code
OKR
Ventricular Bypass (Assist) Device
3
Product Code
OMH
Pericardial Patch To Facilitate Revision Surgeries
2
Product Code
OMR
Vessel Guard Or Cover
2
Product Code
OTD
Endovascular Suturing System
2
Product Code
OVJ
Pulse Generator, External Pacemaker, Dual Chamber
2
Product Code
PAL
Pulmonic Replacement Heart Valve
F
Product Code
PCK
Pediatric Ventricular Assist Device
F
Product Code
PNJ
Leadless Pacemaker
3
Product Code
PNS
Short-Term Intravascular Filter Catheter
2
Product Code
PSQ
Intracardiac Patch Or Pledget, Biologically Derived
2
Product Code
PST
Aortic Annuloplasty Ring
2
Product Code
QAB
Pacing System Analyzer
2
Product Code
Subpart E—Cardiovascular Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Cardiovascular Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 3 April 2026 at 11:13 pm
CV
/
subpart-d—cardiovascular-prosthetic-devices
/
DXY
/
K853017
View Source
ELA MEDICAL CARDIAC PACEMAKERS MULTIL 2 #1251&2251
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K853017
510(k) Type
Traditional
Applicant
ELA MEDICAL, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
7/25/1985
Days to Decision
8 days
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
Subpart B—Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart D—Cardiovascular Prosthetic Devices
DST
Clip, Vena-Cava
DSW
Bag, Polymeric Mesh, Pacemaker
DSY
Prosthesis, Vascular Graft, Of 6mm And Greater Diameter
DSZ
Pacemaker Battery
DTA
Tester, Pacemaker Electrode Function
DTB
Permanent Pacemaker Electrode
DTC
Analyzer, Pacemaker Generator Function
DTD
Pacemaker Lead Adaptor
DTE
Pulse-Generator, Pacemaker, External
DTF
Tools, Pacemaker Service
DTG
Magnet, Test, Pacemaker
DTI
Sizer, Heart-Valve, Prosthesis
DTJ
Holder, Heart-Valve, Prosthesis
DTK
Filter, Intravascular, Cardiovascular
DSP
System, Balloon, Intra-Aortic And Control
DSR
Stimulator, Carotid Sinus Nerve
DSS
Clip, Vascular
DXY
Implantable Pacemaker Pulse-Generator
K
99
3434
PIKOS 01, PIKOS E01, PIKOS 01-B, PIKOS E01-B, PIKOS 01-A, PIKOS E01-A
K
97
0072
OPUS S MODEL 4121 AND 4124 PACEMAKERS
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
K
94
5627
PIKOS LP 01, PIKOS LP E01
K
95
3866
MINIX 834M & MINIX ST 8331M PULSE GENERATORS (MODIFICATION)
K
95
4092
ALTERNATE STERLIZATION PROCESS & MODIFIED DF-1 LEAD CONNECTOR (MODIFICATION)
K
95
3417
MINIFLEX MODEL 340, 341, AND 342 PULSE GENERATORS
K
95
2328
NANOS, PIKOS 01/E01, 01-A, E01-B, LP 01/LP E01
K
95
2364
OPUS PACEMAKERS (MODELS 4001, 4003, 4004, 4023, 4024)
P
95
0037
Siello T/JT, Solia T/JT, Siello S, Solia S, Evia DR, Evia DR-T, Evia SR, Entovis DR, Entovis DR-T, Entovis SR, Entovis S
P
88
0086
Endurity Core, Endurity, Zenex, Zenus
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
95
0037
Ilesto 7 VR-T DX, Ilesto 7 VR-T, Ilesto 5 VR-T DX, Ilesto 5 VR-T, Iforia 7 VR-T DX, Ilesto 7 VR-T (DF4), Ilesto 5 VR-T (
P
95
0029
Smart Monitor, Smart Spot, SmartView Monitor, SmartView HotSpot
P
95
0037
Evia SR-T, Evia SR, Evia DR-T, Evia DR, Entovis SR-T, Entovis DR-T, Entovis DR, Estella SR-T, Estella DR-T, Estella DR,
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
95
0029
Alizea and Celea Pacemakers
P
95
0037
Drug Eluting Permanent Right Ventricular (RV) or Right Atrial (RA) Pacemaker Electrodes
P
95
0037
Pulse Generator, Permanent, Implantable
P
95
0037
Pulse Generator, Permanent, Implantable
P
95
0037
PSW 2100.U and NEO 2100.U
P
95
0037
Evia SR-T, Evia SR, Evia DR-T, Evia DR, Entovis SR-T, Entovis SR, Entovis DR-T, Entovis DR, Estella SR-T, Estella DR-T,
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL and Verity ADx XL
P
94
0031
VIGOR DR/SR, DISCOVERY, and MERIDIAN
P
95
0037
Enticos 4 DR, Enticos 4 D, Enticos 4 SR, Enticos 4 S, Edora 8 DR-T, Evity 8 DR-T, Enitra 8 DR-T, Enticos 8 DR-T, Evity 6
P
95
0029
Reply SR, Reply DR
P
95
0037
Renamic Neo Programmer
P
95
0037
Edora 8 DR-T, Evity 8 DR-T, Enitra 8 DR-T, Enticos 8 DR-T, Evity 6 DR-T, Enitra 6 DR-T, Edora 8 DR, Enitra 6 DR, Edora 8
P
95
0037
Siello S 45 leads and Solia S 45 leads
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL
P
95
0037
Dromos DR/SR Rate Adaptive Pacing Systems
P
95
0037
Edora 8 DR-T, Evity 8 DR-T, Enitra 8 DR-T, Enticos 8 DR-T, Evity 6 DR-T, Enitra 6 DR-T, Edora 8 DR, Enitra 6 DR, Edora 8
P
95
0037
Home Monitoring System Version 3.48
P
88
0086
Assurity, Assurity+, and Endurity
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL
P
95
0029
Reply SR, Reply DR, Esprit SR, and Esprit DR Pacemakers
P
95
0029
Reply SR and Reply DR Pacemakers
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
95
0037
PSW 1904.U
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL, Sustain XL DC, Sust
P
88
0086
Assurity, Endurity Core Family of Pacemakers
P
95
0037
Pulse Generator, Permanent, Implantable
P
95
0037
Pulse Generator, Permanent, Implantable
P
95
0029
Reply SR and Reply DR Pacemakers
P
95
0037
Pulse Generator, Permanent, Implantable
P
95
0029
Reply SR and Reply DR Pacemakers
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL, Sustain XL DC, Sust
P
95
0037
Drug Eluting Permanent Right Venticular/Right Atrial Pacemaker Electrodes, Stylets, Stylet, Catheter, Blind Plug, Perman
P
88
0086
Endurity, Endurity Core, and Assurity pacemakers
P
88
0086
Endurity, Assurity, and Accent
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemaker
P
95
0037
Siello/Solia S Leads Tip
P
88
0086
Endurity, Endurity Core, Assurity and Assurity +
P
95
0037
Pulse Generator, Permanent Implantable DR-T/SR-T
P
95
0037
Pulse Generator, Permanent Implantable, Pulse-Gererator, Pacemaker External, Adapter and Drug Eluting Permanent Right Ve
P
88
0086
Assurity Pacemaker & Endurity Pacemaker
P
14
0033
Assurity MRI Pacemakers and Endurity MRI Pacemakers
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
P
95
0029
Reply/Esprit (5th generation) Electric Hybrid Module
P
95
0037
Pulse Generator, Permanent, Inplantable
P
95
0037
PSW 1901 U
P
95
0037
Pulse Geneerator, Permanent, Implantable
P
95
0037
Setrox S 53; Safio S 53; Dextrus 4136;TILDA R53;Solia S 45/53/60, JT 45/53; Siello S53/60/45/53/60/,JT 45/53;
P
95
0037
Siello S45, S53, S60 and Solia S45, S53, S60
P
94
0031
Accessory Kit
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
95
0037
PSW 1803.U / HMSC 3.40.2 / CardioMessenger Smart
P
95
0037
Evia DR/SR; Evia DR-T/SR-T; Entovis DR/SR, Entovis DR-T/SR-T; Estella DR/SR; Estella DR-T/SR-T; Effecta D/S; Edora 8 DR/
P
14
0033
Quadra Allure/ Quadra Allure MP Cardiac Resynchronization Therapy-Pacemaker (CRT-Ps)
P
95
0037
Pulse Generator, Permanent Implantable, Drug-Eluting Permanent Right Ventricular (RV) or Right Atrial (RA) Pacemaker Ele
P
14
0033
Tendril STS 2088TC Lead
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity XL, Identity ADx XL, Verity ADx XL and Sustain XL DC, S
P
88
0086
Quartet, Victory, Zephyr, Accent, Assurity, Assurity+Endurity, Identity XL, Identity ADx XL, Verity ADx XL, Sustain XL D
P
95
0037
PSW 1802.U, ACTROS, AXOS, BA03, CYLOS, DROMOS, KAIROS, PHILOS, PHILOS II, PROTOS, EVIA, ENTOVIS, ECURO, EFFECTA, ESTELLA
P
95
0037
Siello S 45/53/60, Solia S 45/53/60, Siello T 53/60, Siello JT 45/53, Solia T 53/60, Solia JT 45/53, EFH-6F-W
P
88
0086
Assurity / Assurity+ / Endurity
P
95
0037
Siello T 53; Siello T 60; Siello JT 45; Siello JT 53; Solia T 53; Solia T 60; Solia JT 45; Solia JT 53
P
95
0037
PSW 1801.U
P
88
0086
Victory; Zephyr; Accent; Assurity; Assurity+; Endurity; Identity XL, Identity ADx XL; Verity ADxXL
P
95
0037
Selox ST/JT; Siello S; Solia S; Setrox S; Safio S; S 45-K/53-K; DH; DH IS-1/DF4; EFH-6F-W; S53-K; S 45-S; S 53-S; S 45-F
P
14
0033
Tendril MRI
P
95
0037
Evia DR,DR-T,SR,SR-T; Entovis DR,DR-T,SR-T; Estella DR,DR-T,SR,SR-T; Effecta D,S; Edora 8 DR, 8 SR; Etrinsa 8 DR-T,SR-T,
P
14
0033
Assurity MRI and Endurity MRI
P
88
0086
Assurity, Assurity +, Endurity, Accent and Victory XL
P
95
0037
Evia DR /DR-T /SR/SR-T ;/Entovis DR /DR-T /SR /SR-T; Estella DR / DR-T/ SR /SR-T; Effecta D /S ;/ Endora 8 DR/ 8 SR; /
P
95
0037
Siello S 45, Siello S 53, Siello S 60, Solia S 45, Solia S 53, Solia S 60
P
14
0033
Tendril MRI
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
P
88
0086
Assurity, Assurity +, Endurity
P
14
0033
Endurity MRI, Assurity MRI
P
88
0086
Assurity, Assurity +, Endurity, Endurity Core
P
14
0033
Assurity MRI, Endurity MRI
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
14
0033
Assurity MRI Endurity MRI family of Pacemakers
P
14
0033
Tendril MRI Leads (MRI)
P
14
0033
Tendril
P
95
0029
Pacemakers Reply SR/DR and Esprit SR/DR
P
14
0033
Tendril MRI
P
95
0029
Reply SR / Esprit SR / Reply DR / Esprit DR
P
14
0033
Assurity MRI, Endurity MRI
P
88
0086
Assurity, Endurity
P
14
0033
Assurity MRI, Endurity MRI, Tendril MRI
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity ADx, Verity ADx
P
95
0037
Selox ST/JT; Siello S; Setrox S, Solia S, Safio S
P
95
0037
Dromos DR/DR-A and Dromos SR/SR-B Cardiac Pacing System
P
14
0033
Accent MRI Pacemaker
P
14
0033
Assurity MRI and Endurity MRI
P
88
0086
Assurity, Assurity+, Endurity, Accent, Identity ADx XL, Sustain XL, Verity ADx XL, Victory XL, and Zephyr XL
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
P
95
0029
REPLY & ESPRIT SR & DR Pacemakers
P
14
0033
Tendril MRI Cardiac Lead
P
88
0086
Medical Adhesive
P
88
0086
Assurity, Assurity+, Endurity
P
95
0037
Siello, Solia, Setrox, and Safio
P
14
0033
Low Voltage Active Fixation Lead
P
95
0037
PSW 1704.U
P
14
0033
Tendril MRI Leads
P
14
0033
Tendril MRI
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
14
0033
Assurity MRI and Endurity MRI family of Pacemakers,
P
88
0086
Accent, Assurity, Endurity, Verity ADx, Zephyr, Identity ADx, Victory
P
14
0033
Assurity MRI, Endurity MRI
P
95
0037
Siello S and Solia S, EFH-6F-W and DH IS-1/DF4
P
14
0033
SJM MRI Activator
P
88
0086
Assurity, Endurity, Accent, AddVent, Identity, Entity, Paragon III Sustain
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
14
0033
Assurity MRI PM1272, PM2272; Endurity MRI PM1172, PM2172
P
88
0086
Victory 5816, 5810, 5610; Zephyr 5820, 5826, 5620, 5626; Accent PM1110, PM1210, PM2110, PM2210; Assurity PM1240, PM2240;
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
P
14
0033
Endurity MRI ,Assurity MRI Pacemaker
P
88
0086
Endurity Core, Endurity, Assurity+, Assurity, Sistain, Accent, Zephyr, Victory, Verify ADx XL, Identity Adx, Identity Pa
P
95
0037
PK-222 and PK-Electrode Clip (accessory to Renamic)
P
88
0086
Assurity, Assurity+, and Endurity
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
P
95
0037
PSW 1703.U
P
88
0086
Assurity, Assurity+, Endurity, Accent family of Pacemakers
P
14
0033
Assurity MRI, Endurity MRI family of Pacemakers
P
88
0086
Assurity, Assurity+, Endurity families of ICD Devices
P
95
0037
Setrox S53, S60, Safio S 53, S 60, Solia S 45, S 53, S 60, Siello S 45, S 53, s 60, Blind plug BS IS-1
P
14
0033
Endurity MRI, Assurity MRI
P
88
0086
Endurity, Endurity Core, Assurity, Assurity+
P
95
0029
Reply SR, Reply Dr, Esprit SR, Esprit DR (2nd generation , i.e. V2 ) & (5TH generation i.e.V5)
P
95
0037
Edora, Evity, Enitra, Enticos 8SR/ SR-T/ DR/ DR-T
P
95
0029
SMARTVIEW hotspot
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
P
95
0037
Siello S 45, S53, S60 / Solia S 45, S53, S 60
P
95
0037
Solia S
P
95
0037
Edora / Enitra /Enticos / Evity PSW 1701.U
P
95
0037
Pulse Generator, Permanent Implantable
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
P
88
0086
Accent, Identity, Verity, Victory And Zephyr Pacemakers
P
95
0037
PACEMAKER/ICD/CRT NON IMPLANTED COMPONENTS
P
95
0037
Pacemaker/ICD/CRT non implanted components PSW 1602.U, HMSC 3.34.0
P
88
0086
Victory, Zephyr, Accent, Assurity, Assurity+, Endurity, Identity ADx, Verity ADx
P
14
0033
Assurity MRI, Endurity MRI, Tendril MRI
P
95
0037
Edora 8 DR & DR-T, Evity 8 DR-T,Enitra 8 DR-T, Enticos 8 DR-T, Edora 8 SR-T and SR, Evity 8 SR-T, Enitra 8 SR-T,Enticos
P
14
0033
Tendril MRI leads (MRI)
P
14
0033
Assurity MRI and Endurity MRI Pacemakers, Tendril MRI Lead, MRI Activator, Merlin PCS Programer Software
P
88
0086
PM1160, PM1240, PM1260, PM2160, PM2240, PM2260, PM1152, PM2152
P
88
0086
AFFINITY/ INTEGRITY/ VICTORY/ ZEPHYR/ ACCENT FAMILY OF PACEMAKERS
P
14
0033
Tendril MRI
P
95
0037
PULSE GENERATOR, PERMANENT, IMPLANTABLE
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
P
95
0037
PULSE GENERATOR, PERMANENT, IMPLANTABLE
P
88
0086
ASSURITY, ASSURITY+, ENDURITY, ACCENT FAMILY OF PACEMAKERS
P
95
0037
Linox smart TD 75/18/ 65/18/ 65/16; Linox smart SD 75/18/ 65/18/ 65/16 60/16; Linox smart T65/ S75/ D65/S60; Linox smart
P
95
0029
Reply/Esprit Pacemakers Sorin CRM.
P
95
0029
Repy SR/DR & Esprit SR/DR Pacemakers
P
95
0037
Reocor S, Reocor D
P
88
0086
Assurity, Assurity+, Endurity, Endurity Core
P
95
0029
Reply Sr, Reply DR, Esprit SR, Esprit DR Pacemakers
P
98
0049
Platinum VR/DR ICDS,Paradym RF VR/ RF DR CRT-Ds, Intensia VR, Intensia DR
P
06
0027
Platinium, Paradym RF, RF VR, RF DR, Intensia CRT-Ds
P
88
0086
Assurity - PM1240, PM2240, Assurity+ - PM1260, PM2260, Endurity - PM1160, PM2160, Endurity Core - PM1152, PM2152
P
88
0086
ACCENT, IDENTITY, VERITY, VICTORY AND ZEPHYR PACEMAKERS
P
95
0037
Various models of Evia, Entovis, Estella, Effecta, Ecuro, Eluna, Etrinsa, Epyra Pulse Generator Families
P
95
0029
REPLY SR, REPLY DR, ESPRIT SR, ESPRIT DR Pacemakers
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
P
88
0086
Verity 5056, 5156, 5256, 5356, 5456, 5816; Zephyr 5826, 5626; Identity 5286, 5386; Sustain XL PM1134, PM1136, PM2134, PM
P
95
0029
Reply SR, Reply DR, Esprit SR, Esprit DR
P
91
0023
ST.JUDE MEDICAL ICDS/CRT-D
P
99
0001
VITATRON SOFTWARE MULTIPLE SOFTWARE MODELS
P
89
0003
CARELINK PROGRAMMER (MODEL 2090)/ANALYZER (MODEL 2290)
P
95
0029
SYMPHONY/ELA RHAPSODY PACEMAKER SYSTEM AND THE ORCHESTRA PROGRAMMER
P
88
0086
AFFINITY, IDENTITY, INTEGRITY, AND FRONTIER FAMILY OF DEVICES
P
88
0086
AFFINITY, IDENTITY, INTEGRITY, AND FRONTIER FAMILY OF DEVICES
P
98
0035
KAPPA 700/650/600, KAPPA 900/800 AND ENPULSE E1/E2
P
89
0003
2020A CARDIOSIGHT READER AND MODEL 2491 DEVICE DATA MANAGEMENT
P
89
0003
MEDTRONIC MODEL 2490G CARELINK MONITOR AND MODEL 2491 DDMA SOFTWARE
P
88
0086
PULSE GENERATOR
P
95
0037
PROTOS DR/CLS AND PROTOS VR/CLS
P
98
0035
AT500 DDDRP PACING SYSTEM (MODEL AT500) AND MODEL 9968 SOFTWARE POST-MARKET (RESPECT): ADDING THE ENRHYTHM MODEL P1501DR
P
91
0023
HOUSECALL PLUS TRANSTELEPHONIC MONITORING SYSTEM WITH MODEL 3180-R RECEIVER SOFTWARE (VERSION 2.1)
P
95
0037
IMPLANT CONTROL SYSTEM (ICS) 3000
P
91
0023
CADENCE (R) TIERED THERAPY DEFIBRILLATOR SYSTEM
P
98
0035
MEDTRONIC MODEL P1501DR ENRHYTHM IMPLANTABLE PULSE GENERATOR, MEDTRONIC MODEL 9987 APPLICATION SOFTWARE AND MEDTRONIC MO
P
95
0029
SYMPHONY DR 2550 MODE AND ELAVIEW 1.28 UG1 PROGRAMMING SOFTWARE
P
88
0086
PRE-MOLDED HEADER CONNECTOR DESIGN FOR THE INTEGRITY DR MODEL 5336, IDENTITY DR MODEL 5370, IDENTITY ADX DR MODEL 5380,
P
89
0003
MEDTRONIC MODELS 2490G AND 2490J CARELINK MONITORS AND MODEL 2491 DDMA SOFTWARE
P
99
0001
VITATRON C60 DR (MODEL C60A3) AND VITATRON C20 SR (MODEL C20A3) IMPLANTABLE PULSE GENERATORS AND THEIR ASSOCIATED SOFTWA
P
88
0086
SYCHRONY PULSE GENERATOR
P
91
0023
EPIC AND EPIC+ DR/VR ICD SYSTEMS WITH N2 CAPACITOR
P
95
0029
ELA MEDICAL RATE-RESPONSIVE PACEMAKERS
P
89
0003
MEDTRONIC MODEL 2090 CARELINK PROGRAMMER WITH TELEMETRY C
P
89
0003
CARELINK MONITOR MODELS 2490G, 2490H AND 2490J
P
91
0023
CADENCE TIERED-THERAPY DEFIBRILLATOR SYSTEM
P
91
0020
RELAY
P
98
0035
KAPPA 700, KAPPA 900, ENPULSE
P
99
0001
SELECTION AFM, VITATRON C60 DR, C20 SR, T60 DR, AND T20 SR PACING SYSTEMS
P
88
0086
IDENTITY/IDENTITY ADX, INFINITY AND INTEGRITY FAMILIES OF PACEMAKERS
P
91
0020
RELAY
P
95
0037
SELOX ST/JT STEROID-ELUTING PASSIVE-FIXATION ENDOCARDIAL PACKING LEAD MODELS SELOX ST 53, SELOX ST 60, SELOX JT 45 & 53
P
95
0029
SYMPHONY & ELA RHAPSODY PACEMAKERS
P
89
0003
2490D/E CARELINK MONITORS
P
89
0003
MODEL 2490G/ 2490H/2490J CARELINK MONITORS FOR USE WITH MODEL 2491 DDMA SOFTWARE
P
97
0012
MEDTRONIC KAPPA 400 SERIES PACEMAKERS
P
89
0003
VITATRON LEGACY 11 DR
P
98
0035
KAPPA 700, 800, 900/SIGMA/ENPULSE
P
89
0003
MODEL 9879 SOFTWARE FOR THERA/THERA-I/PRODIGY DEVICES, MODEL 9849 SOFTWARE FOR THE LEGACY II/VISA DEVICES, MODEL 9847...
P
98
0035
MEDTRONIC ENPULSE IMPLANTABLE PULSE GENERATOR AND MODEL 9991 APPLICATIONS SOFTWARE
P
88
0086
MODEL 3150 PACING SYSTEM ANALYZER WAND AND THE MODEL 3307 V4.7 PROGRAMMER SOFTWARE FOR USE WITH MODEL 3510 PROGRAMMERS
P
95
0029
SYMPHONY AND ELA RHAPSODY PACEMAKERS
P
99
0001
VITATRON T60 DR AND T20 SR SYSTEMS
P
98
0035
AT500 DDDRP PACING SYSTEM
P
91
0023
HOUSECALL PLUS TRANSTELEPHONIC MONITORING SYSTEM WITH MODEL 3180-T TRANSMITTER AND MODEL 3180-R RECEIVER SOFTWARE (VERS
P
91
0023
EPIC+ VR MODEL V-196T AND EPIC+ DR MODEL V-239T
P
88
0086
EPIC + DR/VR IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
P
98
0035
ENPULSE IMPLANTABLE PULSE GENERATOR, MODELS E1DR01, E1DR03, E1DR06, E1DR21 AND MODEL 9991 V 2.0 APPLICATION SOFTWARE
P
95
0037
PHILOS DR-T PULSE GENERATOR AND A-K00.1.U/5 PROGRAMMER SOFTWARE
P
95
0037
PHILOS II DR, PHILOS II D, PHILOS II DR-T, PHILOS II SLR, PHILOS II SR, PHILOS II S, AND PROGRAMMER SOFTWARE VERSION A-U
P
98
0035
MEDTRONIC MODEL 2490D CARELINK MONITORS AND MODEL 2491 DDMA SOFTWARE FOR ENPULSE MODELS
P
89
0003
MEDTRONIC MODEL 2490D CARELINK MONITOR
P
98
0035
MEDTRONIC ENPULSE IMPLANTABLE PULSE GENERATOR AND MODEL 9991 APPLICATION SOFTWARE
P
98
0035
MEDTRONIC SIGMA MODELS SS106, SSR306, SC203, SDR203, SD303, SDR303, DR353 AND SVDD303
P
95
0029
SYMPHONY/ELA RHAPSODY ROM MASK T3 (VERSION GXD T3)
P
88
0086
VERITY ADX XL VDR MODEL 5456I PULSE GENERATOR
P
89
0003
2490D/E CARELINK MONITORS & MODEL 2491 DDMA SOFTWARE FOR INSYNC MARQUIS & MAXIMO VR/DR CAPABILITY
P
98
0035
ENPULSE INPLANTABLE PULSE GENERATOR
P
95
0037
PHILOS DR-T PULSE GENERATOR/ICD BELOS VR-T,DR-T,ICD CARDIAC AIRBAG-T
P
89
0003
SYNERGYST PULSE II GENERATOR
P
98
0035
MEDTRONIC KAPPA 700/600 SERIES
P
97
0012
MEDTRONIC. KAPPA 400 SERIES PACEMAKERS
P
91
0023
HOUSECALL PLUS TRANSTELEPHONIC MONITORING SYSTEM WITH MODEL 3180-T TRANSMITTER (SOFTWARE VERSION 1.1) AND MODEL 3180-R
P
88
0086
SYNCHRONY MODEL 2020T PULSE GENERATOR
P
95
0029
SYMPHONY/ELA RHAPSODY PACEMAKER SYSTEM
P
88
0086
ATLAS+ DR/VR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND MODEL 3307 V.4.5A SOFTWARE
P
91
0023
ATLAS+ DR/BR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND MODEL 3307 V.4.5A SOFTWARE
P
98
0035
MEDTRONIC AT500 DDDRP PACING SYSTEM (MODEL AT501) AND MODEL 9968 SOFTWARE
P
89
0003
SYNERGYST II PULSE GENERATOR
P
99
0001
VITATRON DA+ C SERIES PULSE GENERATORS
P
91
0023
ADX PULSE GENERATOR
P
88
0086
ADX PULSE GENERATOR FIRMWARE ANOMALY CORRECTION
P
98
0035
MEDTRONIC KAPPA 900/800 PACEMAKER SERIES
P
95
0037
PHILOS DR ACC PACING SYSTEM AND PROGRAMMER SOFTWARE VERSION B-KAC.V.U/1
P
98
0035
MEDTRONIC SIGMA PACING SYSTEM AND MEDTRONIC 350 SERIES PACING SYSTEM
P
99
0001
MODEL VSA02/VSC02 V9.0 PROGRAMMING SOFTWARE FOR THE DIVA, DEMA, AND SELECTION AFM MODEL 902 PULSE GENERATORS
P
88
0086
IDENTITY ADX XL DC,& SR/ADX VDR/ADX XL DR,DR,SR/VERITY ADX XL VDR/ADX XL DR,DR,DC/ADX XLSR,SR,SC
P
91
0023
IDENTITY ADX XL DC,SR/ADX VDR/ADX XL DR,DR,SR/VERITY ADX XL VDR/ADX XL DR,DR,DC/ADX XLSR,SR,SC
P
88
0086
EPIC PLUS VR/DR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
P
98
0035
AT500DDDRP PACING SYSTEM & MODEL 9968 SOFTWARE
P
88
0086
IDENTITY ADX MODELS XL DR 5386 AND DR 5380 PULSE GENERATORS AND PROGRAMMER SOFTWARE MODEL 3307 V4.2A
P
95
0037
CARDIOMESSENGER HOME MONITORING SYSTEM
P
98
0035
MODEL 2490D/E CARELINK MONITORS AND THE SERVER-BASED MODEL 2491 DEVICE DATA MANAGEMENT SOFTWARE APPLICATION (DDMA)
P
97
0012
KAPPA 400
P
99
0001
DIVA PLATFORM,DERMA PLATFORM
P
98
0035
KAPPA 700/600, 900/800, SIGMA/MEDTRONIC 350
P
88
0086
APPLICATION SOFTWARE MODEL 3307 (VERSION 4.1A)
P
95
0037
PROTOS FAMILY OF PULSE GENERATORS
P
95
0029
TALENT II DUAL-SENSOR IMPLANTABLE CARDIAC PACEMAKERS, MODELS DR233 AND SR133
P
95
0037
PROTOS PULSE GENERATOR (PROTOS VR AND PROTOS DR) AND B-K00.P.U AND A-K00.0.U PROGRAMMER SOFTWARE
P
88
0086
MODEL 3307, V4.0A PROGRAMMING SOFTWARE AND MODEL 3160 ECG ADAPTER CABLE
P
88
0086
ST JUDE MEDICAL EPIC VR/DR IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (MODELS V-197 AND V-235)
P
89
0003
MODEL 9896 SOFTWARE FOR THE JEWEL MODEL 7218
P
98
0035
MEDTRONIC KAPPA 700 SERIES OF IPGS
P
98
0035
MEDTRONIC KAPPA 700 SERIES PULSE GENERATOR PRODUCT FAMILY
P
98
0035
MEDTRONIC KAPPA 700/600/800/900 PULSE GENERATORS
P
93
0022
LEGEND PLUS PACEMAKER FAMILY
P
97
0012
KAPPA 400 PACEMAKER FAMILY
P
98
0035
MEDTRONIC KAPPA/SIGMA PACEMAKER FAMILIES
P
99
0001
DEMA/DIVA IMPLANTABLE PULSE GENERATORS
P
89
0003
MEDTRONIC/VITATRON CARELINK PROGRAMMER
P
89
0003
MEDTRONIC PACING LEADS
P
98
0035
MEDTRONIC KAPPA 900/800 SERIES PLUSE GENERATORS
P
99
0001
PROVIT MODEL VSA02 VERSION 6.1 SOFTWARE BUILD 63 SERVICE RELEASE FOR DEMA, DIVA AND SELECTION AFM FAMILIES OF PULSE GENS
P
98
0035
KAPPA 900/800 IMPLANTABLE PULSE GENERATOR FAMILY SERIES
P
89
0003
THERA/THERA-I
P
98
0035
MEDTRONIC SIGMA AND MEDTRONIC 350 SERIES PULSE GENERATORS
P
88
0086
ATLAS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SYSTEM
P
98
0035
MEDTRONIC KAPPA 900/800 SERIES PACING SYSTEM
P
89
0003
THERA/THERA-I FAMILY OF PULSE GENERATORS
P
98
0035
KAPPA 700/600, SIGMA AND 350 SERIES FAMILIES OF PULSE GENERATORS
P
97
0012
KAPPA 400
P
99
0001
DEMA/DIVA IMPLANTABLE PULSE GENERATORS
P
88
0086
IDENTITY XL DR MODEL 5376 PULSE GENERATOR
P
95
0029
TALENT AND BRIO PACEMAKERS
P
98
0035
MEDTRONIC KAPPA 700/600 PULSE GENERATOR
P
99
0001
DEMA/DIVA IMPLANTABLE PULSE GENERATORS
P
97
0012
KAPPA 400 IMPLANTABLE PULSE GENERATOR
P
88
0086
INTEGRITY AFX DR MODEL 5346
P
88
0086
MODEL 3307 VERSION 2.4A PROGRAMMER SOFTWARE
P
89
0003
MEDTRONIC PACING LEADS
P
88
0086
INTEGRITY AFX DR MODEL 5346 DUAL CHAMBER PULSE GENERATOR AND PROGRAMMER SOFTWARE MODEL 3307, V2.2A
P
95
0029
TALENT PULSE GENERATOR MODELS DR233 AND SR 133 AND PROGRAMMER SOFTWARE CSO 4.18 UG
P
89
0003
MEDTRONIC REVEAL PLUS INSERTABLE LOOP RECORDER (ILR) WITH UPDATED TO THE APPLICATION SOFTWARE (MODEL 09-9 SERIES 2.0)
P
89
0003
9767/9767L PROGRAMMING HEAD AND MODEL9990 DESKTOP SOFTWARE
P
97
0012
MEDTRONIC KAPPA 400 PACING SYSTEM WITH MODEL 9952 VISION - SERIOE 1.3 SOFTWARE
P
99
0001
DEMA, DIVA AND AFM PULSE GENERATORS
P
88
0086
VENTRITEX ICD'S USING MODEL 3307, V2.1A PROGRAMMER SOFTWARE
P
95
0029
BRIO, TALENT, AND OPUS PACEMAKERS AND PROGRAMMER SOFTWARE
P
99
0001
VITATRON DIVA PLATFORM
P
88
0086
INTEGRITY U DR MODEL 5336 AND SR MODEL 5136 PULSE GENERATORS
P
88
0086
VENTRITEX ICD'S
P
88
0086
AFFINITY FAMILY OF PULSE GENERATORS
P
99
0001
VITATRON(R) DEMA PACING SYSTEM
P
95
0029
ELA RATE-RESPONSIVE PACEMAKERS
P
95
0029
TALENT AND BRIO PACEMAKERS (RIGID CONNECTOR)
P
88
0086
INTEGRITY AFX DR/INTEGRITY SR
P
89
0003
MEDTRONIC 9790/9790C PROGRAMMER
P
95
0029
ELA RATE-RESPONSIVE PACEMAKERS
P
88
0086
AV PLUS DX
P
88
0086
AV PLUS DX MODEL 1368 LEAD
P
88
0086
AFFINITY PULSE GENERATORS
P
99
0001
VITATRON DIVA PACING SYSTEM
P
89
0003
SYNERGYST II PMA FAMILY OF IMPLANTABLE PULSE GENERATORS
P
88
0086
MODEL 3307 V1.2A PROGRAMMER SOFTWARE FOR THE MODEL 3500/3510 PROGRAMMERS
P
88
0086
MODEL 3264 REV. B PROGRAMMER SOFTWARE FOR THE APSU MODEL 3250 PROGRAMMER
P
95
0029
TALENT MODEL 213 DUAL-CHAMBER, DUAL SENSOR, IMPLANTABLE CARDIAC PACEMAKER, ELA MEDICAL PROGRAMMER
P
88
0086
INTEGRITY AFX DR (MODEL 5342) & SR (MODEL 5142) PULSE GENERATORS
P
88
0086
AFFINITY VDR MODEL 5430 PULSE GENERATOR
P
88
0086
TRILOGY/SOLUS/PARAGON III/PHOENIX III/SYNCHRONY II,III/ADDVENT TEMPO
P
88
0006
REGENCY SC+, REGENCY SC, REGENCY SCX
P
88
0086
3500/3510 PROGRAMMER
P
89
0003
REVEAL PLUS INSERTABLE LOOP RECORDER MODEL 9809 SOFTWARE
P
97
0012
MEDTRONIC VISION SOFTWARE
P
95
0029
MULTI-PARTITION OPERATING ENVIRONMENT FOR ELA PROGRAMMERS
P
91
0020
IMPLANTABLE PACEMAKER LEADS
P
95
0029
PROGRAMMING SOFTWARE UPGRADE (CSO 4.10 UG)
P
99
0001
VITATRON DIVA IMPLANTABLE PULSE GENERATORS
P
99
0001
VITATRON DIVA
P
88
0086
TENDRIL/PASSIVE PLUS/AV PLUS DX
P
88
0038
NETWORK PROGRAMMER
P
88
0006
SOFTWARE MODEL 3264 REV A
P
88
0086
CARDIAC PACEMAKER PROGRAMMER & BASE STATION
P
90
0070
R5.111WE(REVISION OF R5.85WE)
P
95
0029
BRIO CARDIAC PACEMAKERS
P
88
0086
POLARITY PULSE GENERATOR MODELS 209K AND 2091M/S
P
95
0029
BRIO CARDIAC PACEMAKERS DUAL CHAMBER/DUAL CHAMBER RATE RESPONSIVE
P
95
0037
ACTROS+ FAMILY OF PULSE GENERATORS
P
95
0037
ACTROS SLR+,KAIROS SL PULSE GENERATORS;SL 60-11,13,15 BP SINGLE PASS PACING LEAD;SWM 1000 B-G01.0.U
P
88
0086
AFFINITY/ENTITY DR,DC,SR
P
88
0086
ADDVENT/AV PLUS DX
P
95
0037
ACTROS DR+ -B PULSE GENERATOR
P
88
0086
ADDVENT MODEL 2060LR PULSE GENERATOR AV PLUS SINGLE PASS LEAD MODEL 1328C
P
97
0012
MEDTRONIC KAPPA 400 SERIES IPG'S
P
88
0086
AFFINITY SR MODELS 5130 (LS,RS,L,R)PULSE GENERATORS AFFINITY DR MODELS 5330 (LS, RS,L,R)PULSE GENERATORS
P
88
0086
AFFINITY DR & AFFINITY SR PULSE GENERATORS
P
95
0037
ACTROS+
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
P
95
0037
KAIROS
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
P
95
0029
OPUS RM 4534 AND CHORUS RM 7034 PACEMAKERS
P
89
0039
POLY-SAFE(TM) A-TRACK(TM) PACING LEADS
P
88
0086
TRILOGY FAMILY OF PULSE GENERATORS
P
90
0070
TEMPO FAMILY OF PULSE GENERATORS
P
88
0086
APS III PROGRAMMER WITH SOFTWARE MODEL 3302 REV.D (V1.04)
P
97
0012
MEDTRONIC VISION SOFTWARE MODEL 9952-SERIES 2.1 AND MEDTRONIC. VISION SOFTWARE MODEL 9952A-SERIES 2.1
P
88
0086
SYNCHRONY, SOLUS, PHOENIX, PARAGON AND TRILOGY FAMILY OF PULSE GENERATORS
P
90
0070
TEMPO AND META PULSE GENERATORS
P
88
0006
REGENCY SC, SC+, AND SCX FAMILY OF PULSE GENERATORS
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
P
95
0037
ACTROS DR,D,SR, AND S PULSE GENERATORS AND PMS 1000C PROGRAMMING AND MONITORING SYSTEM
P
89
0003
MODEL 8090 ANALYZER MODEL 5436 ANALYZER PATIENT CABLE, 5104/5104ANALYZER ADAPTORS, AND 8190 ANALYZER SOFTWARE
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
P
88
0006
APSU PROGRAMMER, APSU SOFTWARE, BASE STATION
P
88
0086
APSU PROGRAMMER, APSU SOFTWARE, BASE STATION
P
88
0086
APSU PROGRAMMER, APSU SOFTWARE, BASE STATION
P
90
0070
TEMPO PULSE GENERATORS
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
P
95
0037
ACTROS DR,D,SR, AND S PULSE GENERATORS AND PMS 1000C PROGRAMMING AND MONITORING SYSTEM
P
89
0003
MODEL 9790C PROGRAMMER AND MODEL 9891 PE SOFTWARE
P
91
0020
COSMOS, STRIDE, DASH, DART, UNITY, NOVA, QUANTUM PULSE GENERATORS
P
88
0086
POLARITY PULSE GENERATOR MODELS 209K AND 2091M/S
P
88
0086
POLARITY PULSE GENERATOR MODELS 209K AND 2091M/S
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
P
89
0003
MODEL 9790C PROGRAMMER AND MODEL 9891 PE SOFTWARE
P
89
0003
MEDTRONIC MODEL 5038 CAPSURE VDD-2 LEAD
P
89
0003
MODEL 9790C PROGRAMMER AND MODEL 9891 PE SOFTWARE
P
97
0012
MEDTRONIC . KAPPA 400 SERIES PULSE GENERATORS
P
91
0020
COSMOS, STRIDE, DASH, DART, UNITY, NOVA, QUANTUM PULSE GENERATORS
P
88
0006
APS II 3003 PROGRAMMER WITH MODEL 3203A FUNCTION PACK
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
P
91
0020
MOMENTUM PACERS
P
89
0003
MODEL 9802 E REVEAL INSERTABLE LOOP RECORDER SOFTWARE
P
88
0086
TRILOGY DC+ MODEL 2318L PULSE GENERATOR
P
89
0003
PREVA, PRODIGY, VITATRON AND THERA PACEMAKERS
P
91
0020
EDGEBAND PACER RELAY MODEL 294-03E
P
96
0004
ADDITION OF ALTERNATE TUBING EXTRUDER
P
90
0070
TEMPO PULSE GENERATORS
P
90
0070
MODEL 1256D META MV CARDIAC PULSE GENERATOR
P
88
0086
APS III MODEL 3500 PROGRAMMER
P
96
0004
THINLINE ENDOCARDIAL PACING LEADS
P
90
0070
TEMPO VR 1102 AND TEMPO V 1902
P
90
0070
TEMPO DR 2102 AND TEMP D 2902
P
90
0070
META DDDR MODEL 1256 PULSE GENERATOR
P
91
0020
MOMENTUM PACERS
P
88
0086
TRILOGY DR+ PULSE GENERATOR MODELS 2360L AND 2364L PULSE GENERATORS MODELS 2360L AND 2364L
P
88
0006
APS II 3003 PROGRAMMER WITH MODEL 3203A FUNCTION PACK
P
88
0038
MODEL 9602 PROGRAMMER
P
90
0070
MODEL 1256D META MV CARDIAC PULSE GENERATOR
P
90
0070
MODEL 1256D META MV CARDIAC PULSE GENERATOR
P
88
0086
TRILOGY SR+ MODEL 2260L & 2264L CARDIAC PULSE GENERATORS WITH THE MODEL 3023 PDX FUNCTION PACK
P
95
0029
CHORUS RM MODEL 7034 DDDR PACEMAKER INCL. OPUS RM MODEL 4534 SSIR PACEMAKER
P
91
0020
MARATHON PACING SYSYTEM
P
88
0086
TRILOGY DC + PULSE GENERATOR, MODEL 2318L
P
90
0070
META DDDR PACEMAKER PULSE GENERATORS MODELS 1256, 1256D, & 1256B (FORMERLY 1256R)
P
88
0006
SENSOLOG(R) CARDIAC PACING SYSTEM
P
90
0070
TEMPO DR 2102 AND TEMP D 2902
P
89
0003
PREVA ST DR MODEL 7078 AND THE PREVA D MODEL 7068 IMPLANTABLE PULSE GENERATORS, AND MODEL 9559 SOFTWARE
P
89
0003
SYNERGYST II,ELITE & LEGEND PULSE GENERATORS
P
89
0003
MEDTRONIC 9766A/9766AL PROGRAMMING HEAD
P
88
0006
APS II 3003 PROGRAMMER WITH MODEL 3203A FUNCTION PACK
P
91
0020
MARATHON PACING SYSYTEM
P
95
0037
DROMOS DR/DR-A AND DROMOS SR/SR-B CARDIAC PACING SYSTEMS
P
88
0086
SYNCHRONY,SYNCHRONY II & III SOLUS, SOLUS II & TRIOLOGY PACEMAKERS
P
88
0038
META(TM) III PULSE GENERATOR MODELS 1206, 1206E, 1206M
P
88
0086
TRILOGY DR+ PULSE GENERATOR MODELS 2360L AND 2364L PULSE GENERATORS MODELS 2360L AND 2364L
P
89
0003
MEDTRONIC 9891 BASELINE SOFTWARE/9891 A EPS
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
P
89
0003
MEDTRONIC VDD STEROID-ELUTING LEAD
P
91
0020
UNITY MODEL 292-06 SINGLE PASS PULSE GENERATOR
P
90
0070
META DDDR PACING SYSTEM
P
88
0038
MEDA-MV PACING SYSTEM
P
90
0070
META DDDR PACING SYSTEM
P
88
0038
MEDA-MV PACING SYSTEM
P
89
0039
MAESTRO(R) II SAVVI(TM) PACING SYS MODEL 325 & 333
P
89
0003
MEDTRONIC THERA, PRODIGY AND PREVA PULSE GENERATORS
P
90
0070
NETWORK PROGRAMMER MODEL 9602
P
88
0038
NETWORK PROGRAMMER MODEL 9602
P
90
0070
META DDDR PACING SYSTEM
P
91
0020
MARATHON FAMILY OF PULSE GENERATORS AND THE MODEL 531-66
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
P
89
0003
MEDTRONIC(R) THERA(R) VDD, MODEL 896I, PRODIGY(TM) VDD, MODEL 8168 PULSE GENERATORS AND CAPURE(R) VDD, MODEL 5032 LEAD,
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
P
89
0003
MEDTRONIC SYNERGYST II PULSE GENERATOR SYSTEM
P
88
0006
AFP CARDIAC PACING SYSTEM, SENSOLOG CARDIAC PACING SYSTEM, AND SYNCHRONY CARDIAC PACING SYSTEM
P
88
0086
AFP CARDIAC PACING SYSTEM, SENSOLOG CARDIAC PACING SYSTEM, AND SYNCHRONY CARDIAC PACING SYSTEM
P
88
0086
TRILOGY PULSE GENERATOR MODELS 235OL, 2250L, AND 2308L
P
88
0086
SYNCHRONY III AND PARAGON III DUAL-CHAMBER PULSE GENERATORS
P
89
0003
SYNERGYST II MEDTRONIC MODEL 9889E SOFTWARE
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
88
0038
MEDA-MV PACING SYSTEM
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
87
0054
KELVIN(R) MODEL 513 UNIPOLAR AND MODEL 514 BIPOLAR CARDIAC PULSE GENERATORS.
K
94
0039
PELLETHANE 75D
P
90
0070
META DDDR PACING SYSTEM
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
94
0031
VIGOR(TM) DR PACEMAKER SYSTEM
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
89
0039
MAESTRO(R) II SAVVI(TM) PACING SYS MODEL 325 & 333
K
95
0751
TECOTHANE 75D POLYURETHANE RESIN FOR PULSE GENERATOR CONNECTOR MODULES
K
94
6188
CCDS MAESTRO(R) II SERIES 200 CADIAC PACEMAKER
K
95
0210
CCS MAESTRO(R) II SERIES 200 MODELS 235 AND 227 CARDIAC PACEMAKER
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
P
88
0006
SENSOLOG(R) CARDIAC PACING SYSTEM
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
91
0020
RELAY/DASH/STRIDE/DART PACING SYSTEMS
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
89
0003
MEDTRONIC DUAL CHAMBER PACEMAKERS
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
91
0020
UNITY - C MODEL 292-06 PULSE GENERATOR & ACCS.
P
91
0020
RELAY-DASH PACING SYSTEM
P
91
0020
RELAY-DASH PACING SYSTEM
P
88
0006
SENSOLOG (R) ULTILOG (TM) MODELS 2040K,2040T
P
89
0003
MEDTRONIC(R) MODEL 9870A SOFTWARE DISKETTES
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
89
0003
MEDTRONIC(R) THERA(TM) PULSE GENERATORS
P
89
0039
CCS MODEL 325 PACEMAKER SYSTEM
P
89
0003
MEDTRONIC(R) SYNERGYST II
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
88
0086
SYNCHRONY MODELS PARAGON III/PHOENIX III PACERS
P
89
0003
MEDTRONIC DUAL CHAMBER PACEMAKERS
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
88
0006
OG(R) CARDIAC PACING SYSTEM
P
89
0003
MEDTRONIC DUAL CHAMBER PACEMAKERS
K
94
1937
PIKOS E 01-B
P
88
0086
SYNCHRONY(R) CARDIAC PACING SYSTEM
P
88
0006
SENSOLOG (R)MODEL 3039 FUNCTION PACK
P
88
0086
SYNCHRONY PACING SYS. MODEL 3039 FUNCTION PACK
P
88
0086
SYNCHRONY PACING SYS. MODEL 385 FUNCTION PACK
P
91
0020
RELAY-DASH PACING SYSTEM
P
91
0020
RELAY/DASH/STRIDE & DART PACING SYSTEM
K
93
2884
MINIX/MINIX ST PULSE GENERATORS
P
89
0039
MAESTRO(R) II SAVVI(TM) PACING SYS MODEL 325 & 333
P
89
0003
MEDTRONIC ELITE II(TM) PULSE GENERATOR
P
88
0038
MEDA-MV PACING SYSTEM
P
90
0070
META DDDR PACING SYSTEM
P
89
0003
MEDTRONIC SYNERGYST II PULSE GENERATOR
P
89
0003
MEDTRONIC ELITE II MODEL 7086
P
89
0039
CCS MODEL 325 PACEMAKER SYSTEM
K
92
3026
PIKOS 01-A AND PIKOS E01-A IMPLANTABLE PACEMAKER
P
89
0003
MEDTRONIC MODEL 5424 ELECTROCARDIOGRAM CABLE
P
90
0070
META DDDR PACING SYSTEM MODEL 1254/FUNC.1250H
P
89
0039
CCS MODEL 333 PACEMAKER SYSTEM
P
88
0038
MODEL 9600 VERSION SC.11 PERSONALITY MODULE SOFT
P
88
0086
SOLUS (R) MODELS 2002,2003,SYNCHRONY(R)2022,2023
P
89
0003
MEDTRONIC MODEL 9858 A SOFTWARE DISKETTES
K
93
0770
MEDTRONIC MINIX & MINIX ST PULSE GENERATORS
K
92
3868
CCS MAESTRO II SERIES 200 CARDIAC PACEMAKER
P
90
0070
META DDDR PACING SYSTEM
P
88
0038
MEDA-MV PACING SYSTEM
P
88
0038
MODEL 9600 AUX.INSTRUMENTS INTERFACE CABLE
P
90
0070
CODEL 9600,4810,4510 5603,INTERFACE CABLE
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 305 VDD PACING SYSTEM
P
89
0003
MEDTRONIC MODEL 9858 SOFTWARE DISKETTES
P
89
0039
CCS MODEL 300 PACEMAKER MAESTRO
P
88
0086
SYNCHRONY(R)MODEL 2020T PULSE GEN.,& 3000 PROGRAMM
P
88
0086
SOLUS(R) II MODELS 2006L,2006T,2007K,2007M/S PULSE
P
88
0006
SENSOLOG (R) MODEL 3038 SOFTWARE MODIFICATION
P
91
0020
RELAY(TM) MODELS 294-03 & 293-03 & DASH MODELS
P
88
0086
SOLUS(TM) MODEL 2002L & SYNCHRONY II MODEL 2022L
P
88
0006
SENSOLOG III MODEL 2033B & DIALOG II MODEL 2037B
P
90
0070
MODEL 9600 PROG.,1250H GENERATOR SOFTWARE V4.10UE
P
88
0038
META III MODEL 1206,1206E,1206M PACING SYSTEMS
P
91
0020
RELAY(TM) MODELS 294-03 & 293-03 & DASH MODELS
P
89
0003
MODEL 9760 PROGRAMMING SYSTEM
P
89
0003
MEDTRONIC (R) ELITE II PULSE GENERATOR
P
88
0006
SENSOLOG (R) ALTERNATE PRODUCT TRAY
P
88
0086
SYNCHRONY(R)ALTERNATE PRODUCT TRAY
P
89
0003
MEDTRONIC MODELS ELITE,MINUET,& PRELUDE DR MODIF.
K
92
0601
ASTRA T2, ASTRA T4, ASTRA T6
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
P
89
0003
MEDTRONIC MODEL 9855 SOFTWARE CHANGE
P
88
0086
SYNCHRONY(R) SOFTWARE CHANGE
P
89
0039
CCS MODEL 333 PACEMAKER INTRO. 3 NEW MODELS
P
91
0020
RELAY(TM) MODELS 294-03 & 293-03 & DASH MODELS
P
89
0003
ELITE & PRELUDE DR PULSE GENERATORS
P
88
0086
MODEL 3038 FUNCTION PACK FOR APS-II 3003 PROGRAMME
P
88
0006
MODEL 3038 FUNCTION PACK FOR ASP-II 3003 PROGRAMME
P
89
0003
MODEL 7074, 7075 AND 7077 ELITE(TM) PULSE GENERATO
P
89
0003
MODEL 9760 PROGRAMMING SYSTEM
P
89
0003
MODELS 7107,7108 MINUET PULSE GENERATORS
K
92
0530
INTERMEDICS MODEL 366-15 VS 1 HEADER PLUG
K
92
0157
SCHNEIDER 8 FR. STAMINA(TM) GUIDING CATHETER
P
88
0038
META II MODEL 1204H CARDIAC PACING SYSTEM
P
89
0003
MODEL 7074, 7075 AND 7077 ELITE(TM) PULSE GENERATO
K
91
4109
PIKOS 01 & PIKOS E 01
P
88
0006
SENSOLOG(R)III & DIALOG(R)II PULSE GENERATORS
P
90
0070
META DDDR PACING SYSTEM
P
88
0038
META II MODEL 1204 CARDIAC PACING SYSTEM
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
P
89
0039
POLYSAFE(TM) A-TRACK(TM) MODEL AT-332 ENDOCARDIAL
P
88
0006
MODEL 3037A FUNCTION PACK
P
88
0086
MODEL 3037A FUNCTION PACK
P
89
0003
MODELS 7070,7071,7071M,SYNERGEST(TM)II PULSE GEN
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
P
89
0003
MODEL 9855 SOFTWARE SYSTEM
K
90
5403
MODEL 340 SERIES UNIPOLAR & MODEL 5000B PROGRAMMER
P
88
0038
META II MODEL 1204 CARDIAC PACING SYSTEM
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
P
89
0039
MAESTRO(R) SAVVI(TM) SERIES 300 VDD PACING SYSTEM
P
88
0086
SENSOLOG 2020T, SESOLOG II 2022T, SOLUS 200T
P
88
0086
APS-11 MODEL 3003 PROGRAMMER
P
88
0006
APS-II MODEL 3003 PROGRAMMER
P
88
0006
SENSOLOG III MODEL 2033B & DIALOG II MODEL 2037B
K
91
3134
MODEL 4220
P
88
0086
SOLUS 2002,2003 & SYNCHRONY II 2022,2023 PULSE GEN
P
89
0003
MODEL 9852 SOFTWARE SYSTEM
K
91
2545
MODEL 4205 PULSE GENERATOR SURGICAL EXTEN CABLE
P
89
0003
SYNERGYST(TM) II MODELS 7070/7071 (M) (A)
P
88
0086
SOLUS(TM) MODEL 2002L & SYNCHRONY II MODEL 2022L
K
91
1122
8MM QUANTUM PULSE/SUPRIMA II PULSE GENERATORS
K
90
5824
MAESTRO(R) SERIES 100/200 CARDIAC S/CHAMB PACEMAKE
K
90
5087
TRIOS 02
P
89
0039
MAESTRO(R) MODEL 1006P PACEMAKER PROGRAMMER
P
89
0003
MEDTRONIC ELITE(TM) MODELS 7074,7075,7076,& 7077
P
88
0086
SYNCHRONY II MODEL 2023M/S & SOLAS MODEL 2003M/S
P
88
0086
SYNCHRONY II MODEL 2023M/S & SOLAS MODEL 2003M/S
K
90
3186
OPTIMA SERIES II MODEL 147B SINGLE CHAMBER PULSE
K
90
4941
MAESTRO SERIES 100/200 CARDIAC SINGLE CHAMBER PACE
K
90
4602
MEDTRONIC MODEL 5301B TEST CABLE
P
89
0003
MEDTRONIC SYNERGYST II MODEL 7070 PULSE GENERATOR
K
90
4892
VACUUM BAKE CYCLE
P
88
0086
SYNCHRONY MODEL 2020T CARDIAC PACING SYSTEM
P
89
0003
MEDTRONIC SYNERGYST II MODEL 7070 PULSE GENERATOR
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
P
87
0054
MODEL K (UNIPOLAR) & M (BIPOLAR) ENDOCARDIAL LEADS
K
90
3919
IMPLANTABLE PULSE DEVICES
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
P
89
0039
MASTRO SAVVI SERIES 300 VDD PACING SYSTEM
P
88
0038
META MV MODEL 1202 CARDIAC PACING SYSTEM
K
90
3081
NEOS (TM) 02 B PULSE GENERATOR
P
88
0038
META DDD MODEL 1230 PACER
P
88
0038
META-MV,PACING SYSTEM
K
90
2134
MINIX, MINIX ST, NEW IC: L74
K
90
1535
MODIFIED MEDTRONIC CLASSIX MODEL 8438 PULSE GENE.
P
87
0054
MODEL Q (UNIPOLAR) & R (BIPOLAR) ENDOCARDIAL LEADS
P
88
0086
SYNCHRONY II MODELS 2022T & 2023M - 2002T & 2003M
P
88
0006
SENSOLOG III MODEL 2033B & DIALOG II MODEL 2037B
P
88
0038
META MV MODEL 1202 & 1202 PULSE GENERATORS
P
88
0086
MODEL 3033C FUNCTION PACT
P
88
0086
MODEL 3003 PROGRAMMER MODEL 3036B FUNCTION PACK
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
K
90
0622
MODIFIED MODEL 5401B TEST CABLE
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
P
88
0038
META DDD MODEL 1230 PACER
P
87
0054
KELVIN (R) PACING SYSTEM
K
90
0461
OPUS MODEL 4021, VVI, 5MM UNIPOLAR
K
89
7116
OPTIMA MPT MODEL 5281E AND MODEL 5282E
P
88
0038
META DDD MODEL 1230 PACER
K
89
6809
MEDTRONIC SPECTRAX SXT MODEL 8423M PULSE GENERATOR
P
88
0038
META-MV,PACING SYSTEM
P
89
0003
SYSNERGYST II PULSE GENERATOR MODELS 7070 & 7071
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
P
88
0086
SYNCHRONY II MODELS 2022T & 2023M - 2002T & 2003M
K
89
6184
KALOS 05 PULSE GENERATOR
P
89
0003
SYSNERGYST II PULSE GENERATOR MODELS 7070 & 7071
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
K
89
4239
NANOS
K
89
4240
NEOS 02
K
89
4494
LABELING CHANGES TO PULSE GENE. & PULSE GENE. LEAD
P
88
0038
META-MV,PACING SYSTEM
K
89
5495
ADD'L LABELING TO MINIX MODELS AND MINIX ST MODELS
K
89
4065
OPUS MODEL 4001
K
89
4267
OPUS MODELS 4033 AND 4034
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
P
88
0086
SYNCHRONY MODEL 2020T PULSE GENERATOR
P
88
0038
META-MV,PACING SYSTEM
K
89
1231
OPTIMA MPT AND SPT PACEMAKERS
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
K
89
4055
MINIX 8341M AND MINIX ST 8331M PULSE GENERATORS
K
88
4420
HOME BLOOD PRESSURE KIT, ANEROID
P
88
0086
ACCENT, IDENTITY, VERITY, VICTORY AND ZEPHYR PACEMAKERS
K
89
4185
OPTIMA MPT SERIES III PACEMAKER, UNIPOLAR/BIPOLAR
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
P
88
0038
META-MV,PACING SYSTEM
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
P
88
0038
META-MV,PACING SYSTEM
P
88
0038
META-MV,PACING SYSTEM
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
K
88
5267
VS-1 MODEL NUMBER 251K PULSE GENERATOR
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
K
89
0785
ASTRA T2, T3, T4, T6 PULSE GENERATORS NEW PACKAGE
P
88
0006
SENSOLOG MODEL 703 PULSE GENERATOR & P700 PROGRAMM
K
88
4733
AFP MODEL 262T PULSE GENERATOR
K
88
4411
OPTIMA MPT AND SPT PACEMAKERS
K
88
3037
UNILITH 3 MODELS 7580/7583/7680/7683
K
88
3750
VENTRALITH I
K
88
4215
MINIX 8340, 8341, 8342 MINIX-ST 8330, 8331
K
88
3755
MODIFIED SPECTRAX SX/SXT & PASYS/PASYS ST MODELS
K
88
2391
OPUS 3 PULSE GENERATORS MODELS 4003,4004,4023,4024
K
88
4023
MAESTRO(R) SERIES 100/200 SINGLE CHAMBER PACEMAKER
K
88
2427
CARDIAC PACE. OPUS 4000 MODELS 4043/4044/4063/4066
K
88
3087
PROLOG MP 658M PULSE GENERATOR
K
88
2474
OPUS PULSE GENERATORS MODELS 2001, 2003 AND 2004
K
88
2476
OPUS PULSE GENERATORS MODELS 3001, 3003 AND 3004
K
88
1904
CHANGE TO CATHODE POWDER SPECIFICATION
K
88
1837
OPTIMA MPT SERIES III PACEMAKER, 5281D AND 5282D
K
88
1711
VICOR MODELS 410B & 410D AND MODIFIED 410A PACEMA.
K
88
0898
MULTICOR AND PACEMAKERS
P
87
0054
KELVIN MODEL 500 UNIPOLAR CARDIAC PULSE GENERATOR
K
88
0326
MAESTRO(R) MODELS 115, 118, 215 AND 218 PACEMAKERS
K
88
0422
MAESTRO(R) MODEL 119, SINGLE-CHAMBER PACEMAKER
K
88
0432
VICOR PACER, MODEL 410A
K
87
3158
MODIFIED MULTICOR AND OMNI-STANICOR PACEMAKERS
K
87
4158
CCS IMPLANTABLE MAESTRO(R) SERIES 100/200 PACEMAK.
K
87
4394
QUANTUM(R) MODELS 253-19V & 254-20V PULSE GENERA.
K
87
2766
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE GENERATORS
K
87
2779
PROLOG MP PULSE GENERATORS 658K AND 658T
K
87
3202
VICOR, MODEL 410A
K
87
3528
MODIFIED MODELS 253-19 & 254-20 QUANTUM GENERATORS
K
87
1992
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE GENERATORS
K
87
1866
MEDTRONIC CLASSIX MODELS 8436/8437/8438
K
87
1861
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE GENERATORS
K
87
0142
PINNACLE SR 8701 - UNIPOLAR & 8702 - BIPOLAR
K
86
5013
ASTRA T2, T4 AND T6
K
86
3898
MULTILITH 3 MODELS 1350, 3350, 1370, 3370
K
86
2226
DIALOG MODELS 748, 748K AND 748T PULSE GENERATORS
K
86
0036
EDP-20 PACEMAKER
K
86
2459
MODIFIED CIRCUIT BURN-IN PROCESS IMPLANTABLE PULSE
K
86
3878
TRIOS-M VS-1 PULSE GENERATOR
K
86
3879
NEOS-M VS-1 PULSE GENERATOR
K
86
3582
MODEL 725TH HANDHELD TRANSCEIVER (PROGRAMMER)
K
86
3417
CORDIS MULTICOR II MODEL 402D PACER
K
86
3365
MODIFICATION OF STERILITY CYCLE PARAMETERS
K
86
3418
MODEL 352-01 SILICONE RUBBER ISOLATION SLEEVE
K
86
2974
ALTERNATE PACKAGE CONFIG. FOR IMPLANT. PULSE GEN.
K
85
4790
CERYX PACEMAKER MODELS 114, 314 & 614
K
86
0921
NEOS VS-1, PULSE GENERATOR
K
86
0922
MIKROS, MIKROS VS-1, PULSE GENERATOR
K
86
0585
ASTRA T2, T3, T4 & T6 MULTIPROGRAM PULSE GENERATOR
K
85
3771
PINNACLE MULTI-PROGRAMMABLE PACING SYS
K
86
1719
MODIFIED MODELS 8320/8322/8329/8316/8317/8318
K
86
1422
PACESETTER/SIEMENS PULSE GENERA W/VS-1 HEAD CAVITY
K
86
2071
MODIFIED LABEL FOR/SPECTRAX SXT IMPLANT. PULSE GEN
K
86
2038
MODIFY LABEL/SPECTRAX S & SX IMPLANT PULSE GENER
K
86
2037
MODIFY LABEL/PASYS & MOD 8316/17/18 IMPLAN PUL GEN
K
86
0573
IMPLANT PROG PULSE GENERATOR, UNIPOLAR & BIPOLAR
K
86
1559
SERIES (T) PROGRAMMABLE CARDIAC PULSE GENERATORS
K
86
1140
PROGRAMALITH III PULSE GENERATOR
K
86
1009
BIPOLAR CARDIAC PACEMAKER, MODEL 110
K
85
2973
UNILITH 2 PULSE GENERATORS #7550, 7552, 7760, 7762
K
85
5147
MEDTRONIC MODELS 8316,8317,8318 PULSE GENERATORS
K
85
5081
PHOENIX MODELS 250/251 PULSE GENERATORS
K
85
4482
ALTERNATE STERILE PKG IMPLANTABLE PULSE GENERATORS
K
86
0466
MODEL 329D, SERIERS R BIOPOLAR CARDIAC PUL. GEN.
K
86
0202
MODEL 327D, SERIES R UNIPOLAR CARDIAC PULSE GENER.
K
85
3471
CCS IMPLANTABLE MAESTRO 106/206/210 CARDIAC PACEMA
K
85
3400
CCS IMPLANTABLE MAESTRO SERIES 200 CARDIAC PACEMAK
K
85
5171
TELEMETRY WAND MODEL
K
85
4560
IMPLANTABLE PROGRAMMABLE PULSE GENERATOR
K
85
2641
ORION 40 CARDIAC STIMULATOR & PMP 200 PROGRAMMER
K
85
1968
CORDIS MULTICOR ST, MODEL 350A
K
85
4195
PROGRAMALITH III MODELS 238 & 239
K
85
4919
BIPOLAR CARDIAC PULSE GENERATOR WITH TELEMETRY
K
85
4214
MULTICOR II 402B & 402C MULTIPROGRAM. CARDIAC PACE
K
85
4132
COOK PACEMAKER 332T, SERIES R BIPOLAR CARDIAC PULS
K
85
1365
SORIN BIOMEDICA ORION 30/A CARDIAC STIMULATOR & PM
K
85
2339
SUPRIMA MODEL 254-22
K
85
2340
SUPRIMA MODEL 254-24
K
85
4143
BATTERY INSULATOR FOR USE W/IMPLANTABLE PACEMAKERS
K
85
2748
CORDIS MODELS 336A,336B,337A & 334 CARDIAC PACEMAK
K
85
2688
MEDTRONICS MODELS 8320/8322/8329
K
85
3651
COOK PACEMAKER 33IT R UNIPOLAR CARDIAC PULSE GENER
K
85
3590
COOK PACEMAKER CORP. 327T, SERIES R UNIPOLAR CARDI
K
85
3058
NEOS - M ABP
K
85
3206
IMPLANT PROGRAM CARDIAC PULSE GEN W/MOD SET SCREW
K
85
3057
TRIOS - M
K
85
3425
CARIO-PACE DURAPULSE P101 COATED PULSE GENERATOR
K
85
2435
CCS IMPLANTABLE MAESTRO SERIES 100 CARDIAC PACEMA
K
85
3034
#335-01 SILIC RUB ISOLA SLEEVE FOR INT #281-03 SIZ
K
85
3017
ELA MEDICAL CARDIAC PACEMAKERS MULTIL 2 #1251&2251
K
85
2431
SUPRIMA II MODEL 254-26
K
85
2430
SUPRIMA II MODEL 253-23
K
85
2432
SUPRIMA II MODEL 254-28
K
85
1420
MULTICOR S, MODELS 330A/331A
K
84
4360
CORDIS MULTICOR S 330A & 331A CARDIAC PACEMAKERS
K
85
1419
MULTICOR GAMMA 402 SERIES PACER
K
85
1418
OMNI-ATRICOR MODEL 308A
K
85
1417
MULTICOR GAMMA MODELS 336/337
K
85
1416
STANICOR GAMMA 333B/334A
K
85
1861
PROGRAMALITH III MODEL 249 PULSE GENERATOR
K
85
1699
COOK PACEMAKER CORP. 332T BIPOLAR CARDIAC PULSE GE
K
85
0464
PROGRAMALITH III 240 PULSE GENERATOR
K
84
4842
NEOS-LP PULSE GENERATOR
K
84
4841
KALOS-04 PULSE GENERATOR
K
84
4812
NEOS - PULSE GENERATOR
K
84
4794
LEPTOS PULSE GENERATOR
K
84
4795
NEOS-M PULSE GENERATOR
K
85
1081
IMPLANTABLE PROGRAM-CARDIAC PULSE GEN-OPTIMA MP II
K
85
0252
QMPLANTABLE PROGRAM. CARDIAC PULSE GEN. W/TELEMETR
K
85
0651
PROGRAMALITH III-3 MODEL 231 PULSE GENERATOR
K
85
0384
CCS IMPLANTABLE MAESTRO SERIES 100-HEART PACEMAKER
K
85
0656
COOK 331T UNIPOLAR CARDIAC PULSE GENERATOR W/TELEM
K
84
2051
EKG TRANSMITTER MODEL 5134
K
84
4958
MEDTRONIC MODELS 8432/8433/8434 - PACEMAKER PULSE
K
84
4957
MEDTRONIC MODEL 8436 -PACEMAKER PULSE GENERATOR
K
84
4793
SUPRIMA 253-21 IMPLANTABLE PULSE GENERATOR
K
84
4334
VIVALITH II 301 PULSE GENERATOR
K
84
2193
MULTILITH PULSE GENERATORS, 1141 & 2141
K
84
1230
PULSE GENERATOR 686, 686B 686L
K
84
1232
PULSE GENERATOR 696, 696B & 696L
K
84
1225
PULSE GENERATOR 689, 689B & 689L
K
84
2220
MULTILITH 2 PULSE GENERATOR 1141 & 2141
K
84
2473
IMPLANTABLE PROGRAMMABLE PULSE GENERAT
K
84
3837
MEDTRONIC 5984-5984LP-5985
K
84
2394
ASTRA 2, ASTRA 3, 4 & 6
K
84
3089
MEDTRONIC 8437/8438
K
84
1633
NEOS LP
K
84
1635
LEPTOS
K
84
0748
LITHIUM PACEMAKER 811-811L & 811XL
K
84
1983
COOK PACEMAKER 216 BIPOLAR CARDIAC -
K
84
1928
COOK PACEMAKER 215 UNIPOLAR CARDIAC-
K
84
2081
COOK PACEMAKER CORP. 115 UNIPOLAR CARDI
K
84
1233
PULSE GENERATOR 678L
K
84
1231
PULSE GENERATOR 688B & 688L
K
84
1226
PULSE GENERATOR 728, 728B & 728L
K
84
1228
PULSE GENERATOR 718B & 718L
K
84
1950
PULSE GENERATOR KALOS-04
K
84
1636
NEOS M
K
84
1229
PULSE GENERATOR 698, 698B & 698L
K
84
1404
PRIMA 236-02 NONPROGRAMMABLE CARDIAC
K
84
1073
QUANTUM, UNIPOLAR, MULTI-PROGRAMMABLE
K
84
1075
CARCIAC PULSE GENERATOR 254-20
K
84
1074
CARDIAC PULSE GENERATOR 254-18
K
84
0737
IMPLANTABLE PROGRAMMABLE PULSE GENER
K
84
0701
PACEMAKER 147 VVI-THE OPTINIA
K
83
3428
IMPLANTABLE UNIPOLAR CARDIAC PULSE GEN
K
83
3427
IMPLANTABLE BIPOLAR CARDIAC PULSE GEN
K
83
3519
PULSE GENERATOR MODEL 688
K
83
4096
IMPLANTABLE PULSE GENERATOR
K
83
3798
OPTIMA MDT PULSE GENERATOR W/TELEMETRY
K
83
2914
PRIMA-UNIPOLAR CARDIAC PULSE GENERAT
K
83
3199
SILICONE RUBBER ISOLATION SLEEVE 350-01
K
83
3198
SILICONE RUBBER ISOLATION SLEEVE 351-01
K
83
1860
GENERATOR, PULSE, PACEMAKER #532
K
83
1859
PACEMAKER PROGRAMMER #2032
K
83
1633
QUANTUM BIPOLAR CARDIAC PULSE GENERATOR
K
83
2893
MODEL 329T PROGRAMMABLE, BIPOLAR CARDI
K
83
1771
IMPLANTABLE PROGRAM. CARDIAC PULSE GEN
K
83
2052
MODEL 327T UNIPOLAR CARDIAC PULSE GEN
K
83
1216
COMMAND ULTRA II
K
83
1161
COMMAND ULTRA I
K
83
0344
SIEMENS-ELMA PULSE GENERATOR #718
K
83
0862
NEDS-01 & EPR-500
K
83
0390
IMPLANTABLE BIPOLAR CARDIAC PULSE GEN
K
82
3878
IMPLANTABLE PACEMAKER PULSE GEN, MODELS 241 & 242
K
83
0401
UNILITH PULSE GENERATOR VVI #7542
K
83
0382
COMMAND ULTRA II
K
82
3831
MEDTRONIC MODELS 59401 5941
K
82
3863
CYBERLITH IX QUANTUM-UNIPOLAR CARDIAC
K
82
3559
AFP PULSE GENERATOR
K
82
2639
AFP SYSTEM PULSE GENERATOR MODEL 261/262
K
82
3678
TELEMETRY DECODER #540-02
K
82
3371
DURAPULSE
K
82
2791
CORATOMIC #VX5-105 & VX5-205 PULSE GEN.
K
82
2907
KALOS-03 BIPOLAR
K
82
2904
MODEL 325D UNIPOLAR CARDIAC PULSE GEN
K
82
2652
JAIN INSULATING BOOT MODEL 225B
K
82
2297
ENERTRAX MODEL 7100E
K
82
2309
COMMAND NP
K
82
2147
MEDTRONIC ENERTRAX MODEL 7100
K
82
0939
C-101-P
K
82
1033
CORATOMIC MODEL OVALITH-920
K
82
1014
CORATOMIC MODEL OVALITH 920BP
K
82
1147
COOK #326T PROGRAM/TELEMETRY BIPOLAR
K
82
1073
PULSE GENERATOR
K
82
1003
PROGRAMMALITH II, #225 & 226
K
82
0657
PULSE GENERATOR 678 B
K
82
0853
QUANTUM MODELS 253-09, 254-09 254-10
K
82
0774
IMPLANTABLE, MULTIPROGRAMMABLE
K
82
0356
MULTICOR (GAMMA) 402 CARDIAC PACER
K
82
0231
COMMAND ULTRA I
K
81
3246
MEDICAL MULTILITH PULSE GENERA-1140
K
81
3576
SIEMENS-ELEMA PULSE GENERATOR 659
K
81
3534
COMMAND P5
K
81
3079
BIPOLAR OPTIMA MP #255
K
81
2610
SIEMENS-ELEMA PULSE GENERATOR 668 B
K
81
3150
DIRECTIONAL BOOT
K
81
3101
CARDIOBEEPER MEMORY MONITOR
K
81
2464
SYNTHEMED PULSE GENERATOR VVI MODEL 1000
K
81
2832
MODEL 325C UNIPOLAR CARDIAC PULSE GEN.
K
81
2790
IMPLANTABLE VENTRICULAR-INHIBITED CARDI
K
81
2358
MODEL 325T PROGRAMMABLE PULSE GENERATOR
K
81
2218
KALOS-03
K
81
2580
MEDTRONIC MODEL 2409
K
80
1339
TELEMETRY DECODER
K
80
1337
CYBERLITH IX IMPLANTABLE PULSE GENERATOR
K
81
2096
MEDTRONIC ENERTRAX MODEL 7100
K
81
2153
MEDTRONIC SPECTRAX
K
81
1402
COMMAND P5(BIPOLAR PULSE GENERATOR)
K
81
1768
CORATOMIC MODEL OVALITH-920BP
K
81
1691
CORDIS OMNI-ARTICOR CARDIAC PACER #308
K
81
0887
ELA MEDICAL UNILITH 7540 PULSE GENERATOR
K
81
1350
UNIPOLAR SPECTRAX IMPL. PULSE GENERAT.
K
81
0884
#325 PROGRAMMABLE CARD. PULSE GENERATOR
K
81
0885
#326 PROGRAMMABLE CARD. PULSE GENERATOR
K
81
0489
MULTILITH PULSE GENERATOR #1140
K
81
0142
ELA MEDICAL UNILITH PULSE GENERATOR
K
81
1221
INTERMEDICS CYBERLITH BIPOLAR CARDIAC
K
81
1123
MEDTRONIC PULSE GENERATOR
K
81
0677
MODELS 5976/5977 PACEMAKER PULSE GENER
K
81
0808
CORATOMIC MODEL OVALITH-920
K
81
0734
MODELS 8420 THRU 8423 PACEMAKER GENER
K
81
1066
MODEL 230-06 CYBERLITH TM I BIPOLAR IN
K
81
0800
MODEL 230-05 CYBERLITH I BIPOL. PULSE G.
K
81
0752
THINLITH III UNIPOLAR CARDIAC PULSE GEN.
K
81
0901
INSULATIVE COATING FOR CARD. PULSE GEN
K
81
0603
IMPLANTABLE PROGRAMMABLE CARDIAC PULSE
K
81
0383
INTERMEDICS CYBERLITH I BIOPOLAR CARDI
K
81
0385
CYBERLITH I PULSE GENERATOR MODEL 253-04
K
81
0386
THINLITH II PULSE GNEERATOR MODEL 227-05
K
81
0410
STERILE PACKAGING
K
81
0121
UNIFOCAL 3
K
80
1584
MULTI-PROGRAMMABLE PACEMAKER & PROGRMR.
K
80
2864
SIEMENS-ELEMA PULSE GENERATOR 678
K
81
0036
SIEMENS-ELEMA MYOCARDIAL LEAD
K
80
3197
IMPL. PROGRAMMABLE BIPOLAR CARD.GEN.#274
K
80
1338
CYBERLITH PROGRAMMER
K
80
3035
MICROTHIN-PII BIPOLAR PULSE GEN. #0621
K
80
3034
MICROTHIN-PII BIPOLAR PULSE GEN. #0623
K
80
2353
MICRO THIN-PII, #0523
K
80
2352
MICRO THIN-DII, #0521
K
80
0746
UNIFOCAL VP, MODELS 7501 AND 7502
K
80
1324
SIEMENS-ELEMA PULSE GENERATOR 668
K
80
2588
MODEL 3003 UNIPOLAR DEMAND CARDIAC GEN.
K
79
2609
LITHICRON 0520 P-SYNCHRONEOUS PULSE GEN.
K
80
2410
MICROTHIN-PI BIPOLAR PULSE GENERATOR
K
80
2409
MICROTHIN-DI BIPOLAR PULSE GENERATOR
K
80
1640
SORIN PULSE GENERATOR, MODEL #LIT-214
K
80
2028
IMPLANTABLE VENTRICULAR-INHIB. C.P. GEN
K
80
1978
PROGRAMALITH #'S 221, 222, 221A & 222A
K
80
0379
BIFOCAL 2 8200 SERIES (A,B C,D)
K
80
0793
IMPLANTABLE PROGRAM. CARDIAC PACEMAKER
K
80
1508
SIEMENS-ELEMA PULSE GENERATOR 625
K
80
1910
INSULATING SHEATH
K
80
2040
BATTERY FOR #229-01 PULSE GENERATOR
K
80
1806
EXTERNAL SILASTIC BOOT FOR CARDIAC PULSE
K
80
0226
MEDTRONIC MODEL 2409
K
80
1763
VIVALITH 5, - MDL-201A & TDL-201A
K
80
1647
SONACOLOR 6100
K
80
1450
INTERMEDICS THIN LITH IV SERIES UNIPOLAR
K
80
1106
MULTICOR (GAMMA) MODEL 336 & MODEL 337
K
80
1241
UNIPOLAR PROGRAMMABLE LITHIUM CARD. GEN.
K
80
1122
MICROTHIN-D1 (MOD. 0620)
K
80
1121
MICROTHIN-P1 (MOD. 0622)
K
80
0837
PROGRAMMABLE BIPOLAR CARDIAC GENERATOR
K
80
0069
MEDTRONIC MODELS 5966/5967, ETC.
K
80
0838
ARCOLITH 3022&ARCOLITH 3023 CARDIAC GEN.
K
80
0285
MODEL 5985 PACEMAKER PULSE GENERATOR
K
80
0387
PULSE GENERATORS MODELS 657 & 677
K
80
0895
MODEL 253-11 CYBERLITH PULSE GENERATOR
K
80
0644
CYBERLITH IMPLANTABLE PULSE GEN. #253-02
K
80
0375
NOMOS-01 PULSE GENERATOR
K
80
0645
CYBERLITH IMPLANTABLE PULSE GEN. #253-04
K
80
0573
IMPLANTABLE PROGRAMMABLE BIPOLAR CARDIAC
K
80
0326
ARCOLITH 3021-CARDIAC PULSE GENERATOR
K
80
0194
OVALITH P-BP BIPOLAR CARDIAC PACEMAKER
K
79
2526
PULSE GENERATOR, MODEL NO. LIT 222
K
79
2565
SORIN PULSE GENERATOR MODEL # LIT 214 H
K
80
0026
MICROTHIN-DI
K
80
0027
MICROTHIN-PI
K
80
0030
IMPLANTABLE BIPOLAR CARDIAC PULSE GEN.
K
79
2519
IMPLANTABLE PROGRAMMABLE UNIPOLAR
K
79
2299
ARCOLITH 3020-CARDIAC PULSE GENERATOR
K
79
2216
ARCOLITH 2100-CARDIAC PULSE GENERATOR
K
79
1920
CARDIAC PACEMAKER P4000 SER. & P1000
K
79
2232
UNIFOCAL 3-2 MODELS UNIPOLAR & BIPOLAR
K
79
2199
UNIFOCAL 2-UNIPOLAR & BIPOLAR
K
79
1955
UNIFOCAL 1 UNIPOLAR DEMAND R WAVE
K
79
1316
MEDTRONIC MODELS 5984/5985
K
79
1921
CARDIAC PACEMAKER C4000, C1000 SER.
K
79
2052
IMPLANTABLE PROGRAMMABLE UNIPOLAR CARD
K
79
1783
OMNI-STANICOR (THETA) MOD 237A
K
79
0792
PULSE GENERATOR MODEL 637
K
79
1784
CORDIS BIPOLAR PACER CONNECTOR SYSTEM
K
79
0068
PULSE GENERATORS, MODELS 5983, 5989
K
79
1715
ARCOLITH 2000
K
79
1727
IMPLANTABLE VENTRICULAR-INHIBITED
K
79
1751
EDWARDS PACEMAKER 30 UNIPOLAR GENERATOR
K
79
1181
PROGRAMMER, MEDTRONIC MODEL 5984/5985
K
79
0873
MODEL 221 PROGRAMALITH PULSE GENERATOR
K
79
1568
IMPLANTABLE PULSE GENERATOR PACEMAKERS
K
79
1379
MODEL 228-02 THINLITH II PACEMAKER, BIPO
K
79
1678
LITHICRON II 0403 IMPLANTABLE PACEMAKER
K
79
1417
IMPLANTABLE PULSE GENERATOR PACEMAKER
K
79
1225
BJORK-SHILEY AORTIC GRAFT VALVE PROSTH
K
79
1095
LITHICRON MODEL 0401, PACEMAKER
K
79
0428
MDL-201A & T DL-201A PULSE GENERATOR
K
79
0141
PULSE GENERATOR, R WAVE DEMAND
K
79
1147
ARCO PROGAMMABLE PACEMAKER SYSTEM
K
79
1219
UNILITH PULSE GENERATOR
K
79
0446
OVALITH-300
K
78
2162
BATTERY CHARGER, 171 PACEMAKER
K
78
2161
PULSE GENERATOR, MODEL 171
K
79
1165
ARCOLITH 4000
K
79
0670
PULSE GENERATOR MODEL 629
K
79
1093
MODELS 2411/2418 VENTRICULAR-INHIBITED
K
79
0666
VITALITH S 3000 SERIES
K
79
0867
CARDIAC PULSE GENERATOR, 16 SERIES
K
79
0868
GENERATOR, 16 SERIES, MODIFIED TOP CAP
K
79
0690
OMNI-STANICOR-(THETA) MODEL 217
K
79
0562
PULSE GENERATOR MODEL 61 AND 128
K
79
0452
28 UNIPOLAR AND BIPOLAR PULSE GENERATORS
K
79
0764
PACEMAKERS WITHOUT SILASTIC COATING
K
78
1973
CARDIOPHONE
K
79
0432
MICROLITH MODELS 505;605;507;607;703;803
K
79
0566
PACEMAKER, OVALITH-D CARDIAC
K
79
0276
MINILITH AND MICROLITH
K
79
0014
BIPOLAR, STANICOR LAMBDA MODEL 236,235
K
78
2149
PULSE GENERATOR, IMPLANTABLE CARDIAC
K
79
0101
ISOLATION SLEEVE, MODEL 346-01
K
79
0100
ISOLATION SLEEVE, MODEL 348-01
K
79
0099
ISOLATION SLEEVE, MODEL 347-01
K
79
0098
ISOLATION SLEEVE, MODEL 349-01
K
78
2146
PACEMAKER, MODEL DDP ELECTRONIC CIRCUIT
K
78
2023
MICROLITH A MODEL 803
K
78
2022
MICROLITH A MODEL 703
K
78
0430
LITHICRON F PROGRAMMABLE PULSE GEN
K
78
1835
PULSTRON MODEL 100
K
78
1738
PACEMAKER, MODEL 229-01
K
78
0897
GENERATOR, PULSE, SORIN MODEL DL-1
K
78
1377
OVALITH 10BP
K
78
1252
GENERATOR, PULSE, MODEL 5997
K
78
1208
GENERATORS, PULSE, MODELS 5988/5989
K
78
0776
ARCOBIOLITH PACEMAKER MODEL
K
78
1424
GENERATORS: UDL-201B, BDL-201B, MDL-201B
K
78
0940
GENERATOR, PULSE, MODEL 160B
K
77
2226
PACEMAKER, MODEL 225 & 227
K
78
1426
CARDIAL PULSE GENERATORS
K
78
1178
PULSE GENERATOR MODEL 208
K
78
1090
GENERATOR, CARDIAC PULSE, 250B
K
78
1168
GENERATOR, PULSE, PACEMAKER
K
78
0809
GENERATOR, PULSE MODELS 5920/5921
K
78
0741
GENERATOR, PULSE, DEMAND, MODEL 5996
K
78
1042
PROLITH 23S PACEMAKER
K
78
0781
STILITH CARDIAC PACEMAKERS-M. 60 & 120
K
78
0561
VENTRICULAR INHIBITED PULSE GENERATOR
K
78
0420
GENERATOR, PULSE, CARDIAC, IMPLANTABLE
K
78
0421
GENERATOR, PULSE, CARDIAC, IMPLANTABLE
K
78
0780
MICROPULSE 22S PACEMAKER
K
78
0453
STANICOR THETA MODEL 221 CARDIAC PACER
K
78
0327
GENERATORS, ATRIAL INHIBITED PULSE
K
78
0777
BAGS, PLASTIC, STERILE FOR GENERATORS
K
78
0437
PACEMAKER, MODEL 252, C-MOS
K
78
0238
PACEMAKER, PROLITH 23U. PULSE GENERATOR
K
78
0113
CARDIAC PULSE GENERATOR, MODEL 160B
K
78
0091
MICROPULSE 22U
K
78
0066
CARDIAC PACER, MODEL 208
K
77
2239
PULSE GENERATOR, BIPOLAR, PROGRAMMABLE
K
77
2238
PULSE GENERATOR, UNIPOLAR, PROGRAMABLE
K
77
2241
PULSE GENERATOR, BIPOLAR, DEMAND
K
77
2240
PULSE GENERATOR, UNIPOLAR, DEMAND
K
77
2050
TDL-100 B
K
77
2051
MDL-201
K
78
0061
PULSE GENERATORS, MODELS 5972/5973
K
77
2357
PULSE GENERATORS
K
77
1786
CARDIAC PULSE GENERATORS 5982/5983
K
77
1770
XYREL-RA MODELS 5994/5995
K
77
2202
PULSE GENERATOR, A-V SEQ.
K
77
2010
CARDIAC PACEMAKER C2001
K
77
2009
CARDIAC PACEMAKER S6001
K
77
2057
BIPOLAR PACEMAKER MODEL 224
K
77
2026
CARDIAC PULSE GENERATOR, MODEL 150L
K
77
1992
L-501 CARDIAC PACEMAKER
K
77
1987
MICROPULSE 26U PULSE GENERATOR
K
77
1670
IMPLANTED PACEMAKER PLUSE GENERATOR
K
77
1626
PACEMAKER MODEL 251
K
77
1538
LITHICRON MODEL 3-70C-B PULSE GENERATOR
K
77
1262
PACEMAKER & CARDIAC LEAD, BIPOLAR
K
77
0951
CARDIAC PACERS W/NARROW PULSE WIDTH
K
77
0881
GENERATOR, PULSE, BIPOLAR 3608
K
77
0880
GENERATOR, PULSE, UNIPOLAR, #508
K
77
0716
GENERATOR, PULSE, UNIPOLAR, MODEL #504
K
77
0661
GENERATOR, PULSE, IMPLANTABLE
K
77
0657
GENERATOR, PULSE, CARDIAC 2LU
K
77
0656
GENERATOR, PULSE, CARDIAC 20U
K
77
0715
GENERATOR, PULSE, BIPOLAR, MODEL #604
K
77
0507
PULSE GENERATOR, LITKICRON MODEL 3-70H
K
77
0419
CENTURION
K
77
0559
C-L0L CARDIAC PACEMAKER
K
77
0212
PROLITH MODEL 21S CARDIAC PULSE GEN.
K
77
0211
MICROPULSE MODEL 20S
K
77
0328
PACEMAKER, ANTRIO-VENTRICULAR SEQ.
K
77
0005
PACEMAKER 208S
K
77
0198
BIPOLAR ASYNCHRONOUS PULSE GENERATOR
K
77
0197
UNIPOLAR, ASYNCHRONOUS PULSE GENERATOR
K
77
0135
LEAD MODIFICATION
K
76
1143
LITHIUM IODIDE BATTERY PACEMAKER (#201)
K
76
1237
ELEC. CIR. PACE. MO. LI-2,LI-3,LI-4,LI-5
K
76
0670
PACEMAKERS, VITATRONS (SERIES 2000)
K
76
0669
PACEMAKERS, VITATRON'S
K
76
0671
PACEMAKERS, VITATRONS (SERIES 3000)
K
76
0757
MODEL 100 CARDIAC PACEMAKER
DXZ
Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene
DYE
Replacement Heart-Valve
DYF
Prosthesis, Vascular Graft, Of Less Then 6mm Diameter
KFJ
Materials, Repair Or Replacement, Pacemaker
KRD
Device, Vascular, For Promoting Embolization
KRE
Analyzer, Pacemaker Generator Function, Indirect
KRF
Charger, Pacemaker
KRG
Programmer, Pacemaker
KRH
Ring, Annuloplasty
LDF
Electrode, Pacemaker, Temporary
MAB
Marker, Cardiopulmonary Bypass (Vein Marker)
MAL
Graft, Vascular, Synthetic/Biologic Composite
MFX
Vessel Guard Or Cover, To Facilitate Revision Surgeries
MOP
Rotator, Prosthetic Heart Valve
MZY
Graft, Vascular, Stainless Steel Tunneler
NHW
Electrode, Pacing And Cardioversion, Temporary, Epicardial
NKO
System, Balloon, Intra-Aortic And Control, Reprocessed
OKR
Ventricular Bypass (Assist) Device
OMH
Pericardial Patch To Facilitate Revision Surgeries
OMR
Vessel Guard Or Cover
OTD
Endovascular Suturing System
OVJ
Pulse Generator, External Pacemaker, Dual Chamber
PAL
Pulmonic Replacement Heart Valve
PCK
Pediatric Ventricular Assist Device
PNJ
Leadless Pacemaker
PNS
Short-Term Intravascular Filter Catheter
PSQ
Intracardiac Patch Or Pledget, Biologically Derived
PST
Aortic Annuloplasty Ring
QAB
Pacing System Analyzer
Subpart E—Cardiovascular Surgical Devices
Subpart E—Surgical Devices
Subpart F—Cardiovascular Therapeutic Devices
Subpart F—Therapeutic Devices
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
CV
/
subpart-d—cardiovascular-prosthetic-devices
/
DXY
/
K853017
View Source
ELA MEDICAL CARDIAC PACEMAKERS MULTIL 2 #1251&2251
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K853017
510(k) Type
Traditional
Applicant
ELA MEDICAL, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
7/25/1985
Days to Decision
8 days