MAL · Graft, Vascular, Synthetic/Biologic Composite

Cardiovascular · 21 CFR 870.3450 · Class 2

Overview

Product CodeMAL
Device NameGraft, Vascular, Synthetic/Biologic Composite
Regulation21 CFR 870.3450
Device ClassClass 2
Review PanelCardiovascular
ImplantYes

Identification

A vascular graft prosthesis is an implanted device intended to repair, replace, or bypass sections of native or artificial vessels, excluding coronary or cerebral vasculature, and to provide vascular access. It is commonly constructed of materials such as polyethylene terephthalate and polytetrafluoroethylene, and it may be coated with a biological coating, such as albumin or collagen, or a synthetic coating, such as silicone. The graft structure itself is not made of materials of animal origin, including human umbilical cords.

Classification Rationale

Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular Prostheses 510(k) Submissions.”

Special Controls

*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular Prostheses 510(k) Submissions.”

Recent Cleared Devices (8 of 8)

RecordDevice NameApplicantDecision DateDecision
K122612HEMASHIELD WOVEN DOUBLE VELOUR VASCULAR GRAFT MODEL M00202175XXXXX; M00202166XXXXXMaquet Cardiovascular, LLCSep 10, 2012SESE
K103080ALBOGRAFT VASCULAR PROSTHESISLeMaitre Vascular, Inc.Jan 19, 2011SESE
K093231ALBOGRAFT VASCULAR PROSTHESISLeMaitre Vascular, Inc.Jan 14, 2010SESE
K052302HEMASHIELD PLATINUM WOVEN DOUBLE VELOUR TAAA GRAFT CONFIGURATIONBoston Scientific CorpSep 12, 2005SESE
K021213MODIFICATION TO HEMASHIELD PLATINUM WOVEN/MICROVEL DOUBLE VELOUR VASCULAR GRAFTSBoston Scientific CorpApr 19, 2002SESE
K954848HEMASHIELD MICROVEL VELOUR KNITTED VASCULAR GRAFTMeadox Medicals, Div. Boston Scientific Corp.Feb 1, 1996ST
P920027ALBUMIN COATED DEBAKEY(R) VASCULAR(R) VASCULAR-IIC.R. Bard, Inc.Oct 21, 1994APRL
P890045GELSEAL TM TRIAXIAL VASCULAR GRAFTCarbomedics, Inc.Jan 11, 1993APRL

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...