DXZ · Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene

Cardiovascular · 21 CFR 870.3470 · Class 2

Overview

Product CodeDXZ
Device NamePatch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene
Regulation21 CFR 870.3470
Device ClassClass 2
Review PanelCardiovascular
ImplantYes

Identification

An intracardiac patch or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric device placed in the heart that is used to repair septal defects, for patch grafting, to repair tissue, and to buttress sutures.

Classification Rationale

Class II (performance standards).

Recent Cleared Devices (20 of 90)

Showing 20 most recent of 90 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K240775PeriBeam® Pericardial MembraneTamabioApr 18, 2025SESE
K200955Vascutek Gelseal Patch, Vascutek Gelsoft Patch, Vascutek Thin Wall Carotid PatchVascutek, Ltd.Jul 8, 2020SESE
K162506PhotoFix Decellularized Bovine PericardiumCryolife, Inc.Mar 9, 2017SESE
K162579VascuCelAdmedus Regen Pty, Ltd.Oct 14, 2016SESE
K152127CorMatrix TykeCormatrix Cardiovascular, Inc.Feb 4, 2016SESE
K151865PremiPatch PTFE PledgetAesculap, Inc.Oct 27, 2015SESE
K142447PERI-GUARD Repair Patch & SUPPLE PERI-GUARD Repair PatchSynovis Life Technologies, Inc.Jan 7, 2015SESE
K142461VASCU-GUARD Peripheral Vascular PatchSynovis Life Technologies, Inc.Nov 25, 2014SESE
K140789CORMATRIX ECM FOR VASCULAR REPAIRCormatrix Cardiovascular, Inc.Jul 15, 2014SESE
K130872CARDIOCELCelxcel Pty, Ltd.Jan 30, 2014SESE
K122306SYNOVIS COLLAGEN MATRIX (TBD)Synovis Surgical InnovationsMar 8, 2013SESE
K122105SMI CARDIOVASCULAR PATCHSolinas Medical, Inc.Dec 7, 2012SESE
K112683SMI CARDIOVASCULAR PACHSolimas Medical, Inc.Dec 14, 2011SESE
K111187PATCH, PLEDGET AND INTRACARDIACCormatrix Cardiovascular, Inc.Jul 26, 2011SESE
K101740ALBOSURE POLYESTER VASCULAR PATCHLeMaitre Vascular, Inc.Sep 20, 2010SESE
K101866CRYOPATCH SG PULMONARY HUMAN CARDIAC PATCHCryolife, Inc.Jul 23, 2010SESE
K090637CARDIO-WRAPMast Biosurgery USA, Inc.Jan 7, 2010SESU
K091626CRYOPATCH SG PULMONARY HEMI-ARTERY; TRUNK; BRANCHCryolife, Inc.Aug 7, 2009SESE
K082139EDWARDS BOVINE PERICARDIAL PATCH, MODEL 4700Edwards Lifesciences, LLCOct 23, 2008SESE
K081438MATRACELL DECELLULARIZED PULMONARY ARTERY PATCH ALLOGRAFTLifenet HealthOct 17, 2008SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...