BIPORE BALLOON DILATATION CATHETER
Device Facts
| Record ID | K961980 |
|---|---|
| Device Name | BIPORE BALLOON DILATATION CATHETER |
| Applicant | Bipore, Inc. |
| Product Code | LIT · Cardiovascular |
| Decision Date | Sep 12, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 870.1250 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Bipore Balloon Dilatation Catheter is indicated for Transluminal Percutaneous Angioplasty (PTA) of the iliac, femoral, and renal arteries, and for the treatment of obstructive lesions of autologous or synthetic arteriovenous dialysis fistulae.
Device Story
Double lumen balloon dilatation catheter; used for percutaneous transluminal angioplasty (PTA) in peripheral vessels. One lumen facilitates balloon inflation/deflation; second lumen allows tracking over guidewire to stenosis site. Available in 6mm, 8mm, and 10mm balloon diameters; 4cm balloon length; 5Fr catheter size; 100cm usable length. Operated by clinicians in clinical settings to dilate obstructive lesions. Benefits include restoration of vessel patency and improved blood flow in peripheral arteries and dialysis fistulae.
Clinical Evidence
Bench testing only. In vitro functional testing included balloon burst, multiple inflation, compliance, and inflation/deflation time. Biocompatibility testing included systemic toxicity, intracutaneous toxicity, implantation, hemolysis, and cytotoxicity.
Technological Characteristics
Double lumen catheter design. Materials unspecified. Available in 5Fr size, 100cm length. Balloon diameters: 6, 8, 10mm; length: 4cm. Mechanical inflation/deflation mechanism. No software or electronic components.
Indications for Use
Indicated for patients requiring Transluminal Percutaneous Angioplasty (PTA) of iliac, femoral, or renal arteries, or treatment of obstructive lesions in autologous or synthetic arteriovenous dialysis fistulae.
Regulatory Classification
Identification
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
Predicate Devices
- Medi-tech Ultra-Thin Balloon Dilatation Catheter (K897106)
- Medi-tech Ultra-Thin Balloon Dilatation Catheter (K920547)
Related Devices
- K020854 — MODIFICATION TO FOX PTA CATHETER · Jomed AG · Apr 11, 2002
- K050389 — ULTRA-SOFT SV BALLOON DILATATION CATHETER · Boston Scientific Corp · May 25, 2005
- K992825 — CORDIS EXTREME PTA BALLOON CATHETER · Cordis Corp. · Sep 15, 1999
- K202800 — Pacific Plus PTA Catheter · Medtronic Vascular,Inc(Formerly D.B.A Ev3 Inc.,Covidien, LLC) · Nov 18, 2020
- K980390 — PTA BALLOON CATHETER · Cook, Inc. · Aug 20, 1998