VITROS CHEMISTRY PRODUCTS D%A1C REAGENT KIT, MODEL 680 2314; VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 18, MODEL 680 1702
Device Facts
| Record ID | K060650 |
|---|---|
| Device Name | VITROS CHEMISTRY PRODUCTS D%A1C REAGENT KIT, MODEL 680 2314; VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 18, MODEL 680 1702 |
| Applicant | Ortho-Clinical Diagnostics, Inc. |
| Product Code | LCP · Hematology |
| Decision Date | Apr 6, 2006 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 864.7470 |
| Device Class | Class 2 |
Indications for Use
VITROS Chemistry Products d%A1c Reagent Kit is used to determine the percent glycated hemoglobin (%A1c) in human whole blood by quantitative measurement of hemoglobin (Hb) and hemoglobin A1c (HbA1c). Measurements of percentage Alc are effective in monitoring long-term glycemic control in individuals with diabetes mellitus. VITROS Chemistry Products Calibrator Kit 18 is used in conjunction with VITROS Chemistry Products FS Calibrator 1 to calibrate VITROS 5,1 FS Chemistry Systems for the calculation of percent glycated hemoglobin (%A1c). VITROS Chemistry Products FS Calibrator 1 is used in conjunction with VITROS Chemistry Products Calibrator Kits 16, 17, 18, 19 and 28 to calibrate VITROS 5,1 FS Chemistry Systems.
Device Story
The VITROS d%A1c assay is an in vitro diagnostic test for monitoring long-term glycemic control in diabetic patients. The system utilizes whole blood samples (EDTA) processed on the VITROS 5,1 FS Chemistry System. Unlike the predicate, which required manual sample pretreatment, this device automates hemolysis on-board using a hemolyzing reagent (containing TTAB) integrated into the reagent pack. The assay employs a turbidimetric inhibition immunoassay principle to measure HbA1c and total Hb. The system calculates %A1c based on these measurements. The device is intended for use in clinical laboratory settings by trained laboratory personnel. Results assist healthcare providers in assessing long-term glucose control, enabling adjustments to diabetes management plans. The system includes specific calibrator kits (Kit 18 and FS Calibrator 1) to ensure measurement accuracy.
Clinical Evidence
Bench testing only. Includes precision testing, accuracy testing, method comparison, and stability testing to verify performance following process modifications.
Technological Characteristics
Turbidimetric inhibition immunoassay. Reagents: dual-chambered packs containing ovine HbA1c antibody, polyhapten, buffers, stabilizers, preservatives, and TTAB-based hemolyzing reagent. Instrumentation: VITROS 5,1 FS Chemistry System. Sample type: EDTA whole blood. Calibration: lyophilized hemolysate calibrators. Connectivity: system-integrated.
Indications for Use
Indicated for the quantitative measurement of hemoglobin A1c (HbA1c) and total hemoglobin (Hb) in human whole blood to determine percent glycated hemoglobin (%A1c). Used for monitoring long-term glycemic control in individuals diagnosed with diabetes mellitus.
Regulatory Classification
Identification
A glycosylated hemoglobin assay is a device used to measure the glycosylated hemoglobins (A1a , A1b , and A1c ) in a patient's blood by a column chromatographic procedure. Measurement of glycosylated hemoglobin is used to assess the level of control of a patient's diabetes and to determine the proper insulin dosage for a patient. Elevated levels of glycosylated hemoglobin indicate uncontrolled diabetes in a patient.
Predicate Devices
- k041764
- k052645
Related Devices
- K041764 — THE VITROS 5,1 FS CHEMISTRY SYSTEM · Ortho-Clinical Diagnostics · Sep 9, 2004
- K142595 — VITROS Chemistry Products HbA 1c Reagent Kit, VITROS Calibrator Kit 31, VITROS Chemistry Products %A1c Performance Verifiers I and II · Ortho Clinical Diagnostics · Jun 4, 2015
- K102045 — DIMENSION VISA HBA1C, MODEL K3105A · Siemens Heatlhcare Diagnostics, Inc. · Feb 14, 2011