EASYPLUS MINI R9N SELF MONITORING BLOOD GLUCOSE SYSTEM MODEL EPS10031
Device Facts
| Record ID | K101457 |
|---|---|
| Device Name | EASYPLUS MINI R9N SELF MONITORING BLOOD GLUCOSE SYSTEM MODEL EPS10031 |
| Applicant | Eps Bio Technology Corp. |
| Product Code | NBW · Clinical Chemistry |
| Decision Date | Jul 1, 2010 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 862.1345 |
| Device Class | Class 2 |
| Attributes | Pediatric |
Indications for Use
The EasyPlus mini R9N SMBG Test System is intended for the quantitative measurement of glucose in fresh capillary whole blood samples drawn from the fingertips or forearm. Testing is done outside the body (In Vitro diagnostic use). It is indicated for use at home (over the counter [OTC]) by persons with diabetes, or in clinical settings by healthcare professionals, as an aid to monitor the effectiveness of diabetes control. This device is not intended for the diagnosis or screening of diabetes mellitus and is not intended for use in neonates. Alternate Site Testing (AST) in the EasyPlus mini R9N Blood Glucose Monitoring System can be used only during steady-state blood glucose conditions.
Device Story
EasyPlus mini R9N SMBG system measures glucose in fresh capillary whole blood; samples obtained via fingerstick or forearm. System comprises meter, test strips, and control solutions. Used by patients at home or healthcare professionals in clinical settings to monitor diabetes management. Principle of operation involves electrochemical measurement of glucose concentration in blood sample applied to test strip. Meter processes electrical signal to calculate glucose level; displays result on screen. Provides quantitative data to assist in diabetes control; not for diagnostic or screening purposes. Requires steady-state conditions for alternate site testing.
Clinical Evidence
No clinical data provided. Substantial equivalence supported by design control activities, risk analysis (FMEA), and verification/validation testing of the modified hardware components.
Technological Characteristics
Electrochemical glucose monitoring system; consists of handheld meter, disposable test strips, and control solutions. Operates via enzymatic reaction on test strip; electrical signal measured by meter. Battery-powered. No connectivity features described.
Indications for Use
Indicated for quantitative glucose measurement in fresh capillary whole blood (finger, palm, forearm, upper arm, calf, thigh) for home use by individuals with diabetes to monitor glycemic control. Not for diabetes diagnosis, screening, or neonatal use.
Regulatory Classification
Identification
A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.
Special Controls
*Classification.* Class II (special controls). The device, when it is solely intended for use as a drink to test glucose tolerance, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.
Related Devices
- K091481 — EASYPLUS MINI R13N SELF MONITORING BLOOD GLUCOSE SYSTEM · Eps Bio Technology Corp. · Aug 18, 2009
- K063212 — CLEVER CHEK TD-4231 AND TD-4223 BLOOD GLUCOSE MONITORING SYSTEM · Taidoc Technology Corporation · Nov 22, 2006
- K092894 — EASYMAX V SELF MONITORING BLOOD GLUCOSE SYSTEM · Eps Bio Technology Corp. · Feb 24, 2010
- K094005 — FORA G31A/TD-4256A BLOOD GLUCOSE MONITORING SYSTEM AND FORA G31B/TD-4256B BLOOD GLUCOSE MONITORING SYSTEM · Taidoc Technology Corporation · May 5, 2010
- K093506 — CLEVER CHOICE AUTO-CODE PRO BLOOD GLUCOSE MONITORING SYSTEM MODEL TD-4267 · Taidoc Technology Corporation · Apr 1, 2010