Access Intrinsic Factor Ab

K240800 · Beckman Coulter, Inc. · LIG · May 3, 2024 · Clinical Chemistry

Device Facts

Record IDK240800
Device NameAccess Intrinsic Factor Ab
ApplicantBeckman Coulter, Inc.
Product CodeLIG · Clinical Chemistry
Decision DateMay 3, 2024
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1810
Device ClassClass 2

Indications for Use

The Access Intrinsic Factor Ab assay is a paramagnetic particle, chemiluminescent immunoassay for the detection of intrinsic factor antibody in human serum and plasma using the Access Immunoassay Systems. It is intended for in vitro diagnostic use as an aid in the diagnosis of pernicious anemia.

Device Story

Access Intrinsic Factor Ab is a competitive binding immunoenzymatic assay; utilizes paramagnetic particles and chemiluminescence for detection. Input: human serum or plasma samples. Process: competitive binding reaction performed on Dxl 9000 Access Immunoassay Analyzer; analyzer automates sample processing, incubation, and signal measurement. Output: intrinsic factor antibody concentration (AU/mL). Used in clinical laboratory settings by trained laboratory personnel. Results interpreted by clinicians to aid in diagnosis of pernicious anemia. Benefits: provides standardized, automated diagnostic testing for pernicious anemia.

Clinical Evidence

Bench testing only. Method comparison study of 128 serum samples between Dxl 9000 and Access 2 systems showed 100% negative agreement and 97.5% positive agreement (total agreement 96.9%). Precision study (CLSI EP05-A3) demonstrated within-laboratory imprecision (total CV) ≤ 4.4% across concentrations ranging from 1.0 to 14.0 AU/mL, meeting the ≤ 10.0% CV design goal.

Technological Characteristics

Paramagnetic particle, chemiluminescent immunoassay. Competitive binding immunoenzymatic assay. Analyte: Intrinsic factor antibody. Sample matrix: serum and plasma. Instrument: Dxl 9000 Access Immunoassay Analyzer. Substrate: Lumi-Phos Pro. Calibration: single-level liquid synthetic matrix (1.0 AU/mL).

Indications for Use

Indicated for the detection of intrinsic factor antibodies in human serum and plasma to aid in the diagnosis of pernicious anemia.

Regulatory Classification

Identification

A vitamin B12 test system is a device intended to measure vitamin B12 in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of anemias of gastrointestinal malabsorption.

Related Devices

Submission Summary (Full Text)

{0} 1 # 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION ## TRIAGE-QUICK REVIEW DECISION SUMMARY 510(k) Number: K240800 This 510(k) was reviewed under the OHT7/OHT8 OIR’s Triage-Quick Review Program. This program represents an internal workload management tool intended to reduce internal FDA review resources for 510(k) applications that are of good quality upon receipt by FDA. The information in the 510(k) is complete and supports a substantial equivalence (SE) determination. Please refer to the applicant’s 510(k) summary for a summary of the information that supports this SE determination.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...