PBF · Orthopaedic Surgical Planning And Instrument Guides

Orthopedic · 21 CFR 888.3030 · Class 2

Overview

Product CodePBF
Device NameOrthopaedic Surgical Planning And Instrument Guides
Regulation21 CFR 888.3030
Device ClassClass 2
Review PanelOrthopedic

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Classification Rationale

Class II.

Recent Cleared Devices (20 of 27)

Showing 20 most recent of 27 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K252064MedCAD® AccuStride™ SystemMedcadMar 27, 2026SESE
K250711VSP Orthopedics System3D Systems, Inc.Dec 5, 2025SESE
K242603MyPAO SA guidesMedacta International S.A.Nov 19, 2025SESE
K251709MedCAD® AccuStride™ SystemMedcadNov 4, 2025SESE
K250394Fine TTO™Bodycad Laboratories, Inc.Oct 21, 2025SESE
K250767Newclip Patient-matched instrumentation non sterile PSINewclip TechnicsOct 1, 2025SESE
K250921CORIOGRAPH Pre-Op Planning and Modeling ServicesBlue Belt Technologies, Inc.Jun 25, 2025SESE
K241811MedCAD® AccuStride™ SystemMedcadMar 13, 2025SESE
K243912Newclip Patient-matched instrumentation non sterile PSINewclip TechnicsFeb 13, 2025SESE
K240415Newclip Patient-matched instrumentation non sterile PSINewclip TechnicsNov 7, 2024SESE
K240113CORIOGRAPH Knee Pre-Op PlanSmith & Nephew, Inc.Mar 18, 2024SESE
K240066Fine Osteotomy™Bodycad Laboratories, Inc.Feb 9, 2024SESE
K221615Newclip Patient-matched instrumentation non sterile PSINewclip TechnicsOct 25, 2023SESE
K223421MedCAD AccuPlan Orthopedics SystemMedcadSep 20, 2023SESE
K231314Fine Osteotomy™Bodycad Laboratories, Inc.Jun 2, 2023SESE
K220706MyPAO GuidesMedacta International S.A.May 30, 2023SESE
K221943EmbedMed3D Lifeprints UK , Ltd.Feb 1, 2023SESE
K211614CenterMed Patient Matched Assisted Surgical Planning (ASP) SystemCentermed, Inc.Aug 4, 2022SESE
K211076Patient Specific Marking GuidesAdditive Orthopaedics, LLCJun 28, 2022SESE
K220717RedPoint Medical's Better Bunion SystemRedpoint Medical, LLCJun 9, 2022SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...