OQB · Intervertebral Body Graft Containment Device

Orthopedic · 21 CFR 888.3085 · Class 2

Overview

Product CodeOQB
Device NameIntervertebral Body Graft Containment Device
Regulation21 CFR 888.3085
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

An intervertebral body graft containment device is a non-rigid, implanted spinal device that is designed to contain bone graft within its internal cavity. The device is inserted into the intervertebral body space of the spine and is intended as an adjunct to intervertebral body fusion.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) Clinical performance testing must include an assessment of any adverse events observed during clinical use, as well as intervertebral body fusion, and compare this to a clinically acceptable fusion rate. (2) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant, as well as the ability of the device to be inserted, deployed, and filled with bone graft consistently. (3) Device must be demonstrated to be biocompatible. (4) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components, and device-specific instruments. (5) Design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (6) Labeling must bear all information required for the safe and effective use of the device, specifically including the following: (i) A clear description of the technological features of the device including identification of device materials, compatible components in the fusion construct, and the principles of device operation; (ii) Intended use and indications for use, including levels of fixation; (iii) Identification of magnetic resonance (MR) compatibility status; (iv) Cleaning and sterilization instructions for devices and instruments that are provided nonsterile to the end user; and (v) Detailed instructions of each surgical step, including device removal.

Recent Cleared Devices (4 of 4)

RecordDevice NameApplicantDecision DateDecision
K251302OptiMesh Multiplanar Expandable Interbody Fusion SystemSpineology, Inc.Dec 15, 2025SESE
K230927OptiMesh Multiplanar Expandable Interbody Fusion SystemSpineology, Inc.Nov 1, 2023SESE
K231781OptiMesh Multiplanar Expandable Interbody Fusion SystemSpineology, Inc.Oct 18, 2023SESE
DEN200010Spineology Interbody Fusion SystemSpineology, Inc.Sep 18, 2020DENG

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...