NQP · Posterior Metal/Polymer Spinal System, Fusion

Orthopedic · 21 CFR 888.3070 · Class 2

Overview

Product CodeNQP
Device NamePosterior Metal/Polymer Spinal System, Fusion
Regulation21 CFR 888.3070
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

(1) Rigid pedicle screw systems are comprised of multiple components, made from a variety of materials that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of screws, longitudinal members (e.g., plates, rods including dual diameter rods, plate/rod combinations), transverse or cross connectors, and interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors).(2) Semi-rigid systems are defined as systems that contain one or more of the following features (including but not limited to): Non-uniform longitudinal elements, or features that allow more motion or flexibility compared to rigid systems.

Classification Rationale

Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls. (Also includes Class II designations for rigid systems for degenerative disc disease and semi-rigid systems).

Special Controls

*Classification.* (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:(i) Compliance with material standards; (ii) Compliance with mechanical testing standards; (iii) Compliance with biocompatibility standards; and (iv) Labeling that contains these two statements in addition to other appropriate labeling information: “Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.” “Precaution: The implantation of pedicle screw spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this pedicle screw spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.” (2) Class II (special controls), when a rigid pedicle screw system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion in the treatment of degenerative disc disease and spondylolisthesis other than either severe spondylolisthesis (grades 3 and 4) at L5-S1 or degenerative spondylolisthesis with objective evidence of neurologic impairment. These pedicle screw systems must comply with the following special controls: (i) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (ii) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant. (iii) Device components must be demonstrated to be biocompatible. (iv) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (v) Labeling must include the following: (A) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (B) Intended use and indications for use, including levels of fixation; (C) Identification of magnetic resonance (MR) compatibility status; (D) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user; and (E) Detailed instructions of each surgical step, including device removal. (3) Class II (special controls), when a semi-rigid system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion for any indication. In addition to complying with the special controls in paragraphs (b)(2)(i) through (v) of this section, these pedicle screw systems must comply with the following special controls: (i) Demonstration that clinical performance characteristics of the device support the intended use of the product, including assessment of fusion compared to a clinically acceptable fusion rate. (ii) Semi-rigid systems marketed prior to the effective date of this reclassification must submit an amendment to their previously cleared premarket notification (510(k)) demonstrating compliance with the special controls in paragraphs (b)(2)(i) through (v) and paragraph (b)(3)(i) of this section.

Recent Cleared Devices (20 of 22)

Showing 20 most recent of 22 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K203678CD HORIZON™ Spinal SystemMedtronic Sofamor Danek USA, Inc.Jan 15, 2021SESE
K191066CD Horizon™ Astute™ Spinal SystemMedtronic Sofamor Danek USA, Inc.Oct 3, 2019SESE
K182928CD Horizon™ Spinal SystemMedtronic Sofamor Danek USA, Inc.Jan 11, 2019SESE
K133164DYNESYS TOP-LOADING SPINAL SYSTEMZimmer Spine, Inc.Jan 16, 2014SESE
K101704ZIMMER DTO PIN PRESS INSTRUMENTZimmer Spine, Inc.Aug 18, 2010SESE
K101083DSS STABILIZATION SYSTEMParadigm Spine, LLCJul 2, 2010SESU
K092234DYNESYS TOP-LOADING SPINAL SYSTEMZimmer Spine, Inc.Oct 1, 2009SESE
K091944MODIFICATION TO: DSS STABILIZATION SYSTEMParadigm Spine, LLCAug 3, 2009SESE
K073439TRANSITION STABILIZATION SYSTEMGlobus Medical, Inc.Feb 20, 2009SESU
K080241DDS STABILIZATION SYSTEMParadigm Spine, LLCNov 28, 2008SESU
K080963DSS STABILIZATION SYSTEMParadigm SpineMay 2, 2008SESE
K071261ISOBAR SEMI-RIGID DUAL DAMPENERScient'XApr 17, 2008SESE
K072321BIOFLEXBiospine Co., Ltd.Mar 25, 2008SESE
K073347DYNESYS TOP-LOADING SPINAL SYSTEMZimmer Spine, Inc.Feb 8, 2008SESU
K072969DSSParadigm Spine, LLCJan 24, 2008SESU
K072685NGARDE SYSTEMN Spine, Inc.Oct 19, 2007SESU
K071879ZIMMER DTO IMPLANTZimmer Spine, Inc.Oct 5, 2007SESU
K061774NFIX II PEDICLE SCREW SYSTEMN Spine, Inc.Dec 13, 2006SESU
K061304CD HORIZON SPINAL SYSTEMMedtronic Sofamor DanekJul 18, 2006SESE
K060638DYNESYS SPINAL SYSTEM WITH HA COATED SCREWSZimmer Spine, Inc.Apr 6, 2006SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...