KTB · Device, Iontophoresis, Specific Uses

Physical Medicine · 21 CFR 890.5525 · Class 2

Overview

Product CodeKTB
Device NameDevice, Iontophoresis, Specific Uses
Regulation21 CFR 890.5525
Device ClassClass 2
Review PanelPhysical Medicine
3rd-Party ReviewableYes

Identification

An iontophoresis device is a device that is intended to use a direct current to introduce ions of soluble salts or other drugs into the body and induce sweating for use in the diagnosis of cystic fibrosis or for other uses if the labeling of the drug intended for use with the device bears adequate directions for the device's use with that drug. When used in the diagnosis of cystic fibrosis, the sweat is collected and its composition and weight are determined. Additionally, an iontophoresis device intended for any other purposes is a prescription device that is intended to use a current to introduce ions of drugs or non-drug solutions into the body for medical purposes other than those specified in paragraph (a) of this section, meaning that the device is not intended for use in diagnosis of cystic fibrosis, or a specific drug is not specified in the labeling of the iontophoresis device.

Classification Rationale

Class II (special controls). The device is classified as class II.

Special Controls

*Classification.* Class II (special controls). The device is classified as class II. The special controls for this device are:(i) The following performance testing must be conducted: (A) Testing using a drug approved for iontophoretic delivery, or a solution if identified in the labeling, to demonstrate safe use of the device as intended; (B) Testing of the ability of the device to maintain a safe pH level; and (C) If used in the ear, testing of the device to demonstrate mechanical safety. (ii) Labeling must include adequate instructions for use, including sufficient information for the health care provider to determine the device characteristics that affect delivery of the drug or solution and to select appropriate drug or solution dosing information for administration by iontophoresis. This includes the following: (A) A description and/or graphical representation of the electrical output; (B) A description of the electrode materials and pH buffer; (C) When intended for general drug delivery, language referring the user to drug labeling approved for iontophoretic delivery to determine if the drug they intend to deliver is specifically approved for use with that type of device and to obtain relevant dosing information; and (D) A detailed summary of the device-related and procedure-related complications pertinent to use of the device, and appropriate warnings and contraindications, including the following warning: *Warning:* Potential systemic adverse effects may result from use of this device. Drugs or solutions delivered with this device have the potential to reach the blood stream and cause systemic effects. Carefully read all labeling of the drug or solution used with this device to understand all potential adverse effects and to ensure appropriate dosing information. If systemic manifestations occur, refer to the drug or solution labeling for appropriate action.(iii) Appropriate analysis/testing must demonstrate electromagnetic compatibility, electrical safety, thermal safety, and mechanical safety. (iv) Appropriate software verification, validation, and hazard analysis must be performed. (v) The elements of the device that may contact the patient must be demonstrated to be biocompatible. (vi) The elements of the device that may contact the patient must be assessed for sterility, for devices labeled as sterile. (vii) Performance data must support the shelf life of the elements of the device that may be affected by aging by demonstrating continued package integrity and device functionality over the stated shelf life.

Recent Cleared Devices (16 of 16)

RecordDevice NameApplicantDecision DateDecision
K180627Macroduct Advanced Model 3710Elitechgroup, Inc.Jul 27, 2018SESE
K033192RH-950Iomed, Inc.Dec 22, 2003SESE
K031551NORTHSTAR LIDOCAINE IONTOPHORETIC CONTROLLER (NORTHSTAR CONTROLLER-D)Vyteris, Inc.Aug 20, 2003SESE
K031115RH-900Iomed, Inc.Jul 10, 2003SESE
K010031NANODUCT NEONATAL SWEAT ANALYSIS SYSTEMWescor, Inc.Mar 20, 2001SESE
K001522TRANSQ3Iomed, Inc.Oct 18, 2000SESE
K001410PHORESOR MODEL PM2000Iomed, Inc.Aug 1, 2000SESE
K992874Q-SWEAT QUANTITATIVE SWEAT MEASUREMENT SYSTEMWr Medical Electronics Co.Nov 18, 1999SESE
K974855PHORESOR II, MODEL PM900Iomed, Inc.Mar 27, 1998SN
K954126TRANSQ ELECTRODE PHORESOR IIIomed, Inc.Jan 19, 1996SN
K895775CF INDICATOR MODEL 9800 SWEAT TEST SYSTEMMedtronic VascularApr 23, 1990SESE
K853973WESCOR MODEL 3700 WEBSTER SWEAT INDUCERWescor, Inc.Oct 16, 1985SESE
K840472SYS MACRODUCT SWEAT COLLECTION SYS 3600Wescor, Inc.Mar 19, 1984SESE
K832059IONOPHORELIC SWEAT STIM. CHLORIDE-Medtronic VascularAug 24, 1983SESE
K790205ELECTROAPPLICATOR MODEL C-1Mcg, Inc.Mar 19, 1979SESE
K781700IONOTPHORETIC APPLICATORMcghan Medical Corp.Nov 3, 1978SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...