KRO · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer

Orthopedic · 21 CFR 888.3510 · Class 2

Overview

Product CodeKRO
Device NameProsthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
Regulation21 CFR 888.3510
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device limits translation or rotation in one or more planes and has components that are linked together or affined. This generic type of device includes prostheses composed of a ball-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a ball at the head of a column rising from the stemmed tibial component. The ball, the column, the tibial plateau, and the stem for fixation of the tibial component are made of an alloy, such as cobalt-chromium-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the femoral component's flat outer surface. The flat outer surface of the tibial component abuts both a reciprocal flat surface within the cavity of the femoral component and flanges on the femoral component designed to prevent distal displacement. The stem of the femoral component is made of an alloy, such as cobalt-chromium-molybdenum, but the socket of the component is made of ultra-high molecular weight polyethylene. The femoral component has metallic runners which align with the ultra-high molecular weight polyethylene tracks that press-fit into the metallic tibial component. The generic class also includes devices whose upper and lower components are linked with a solid bolt passing through a journal bearing of greater radius, permitting some rotation in the transverse plane, a minimal arc of abduction/adduction. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).

Classification Rationale

Class II.

Recent Cleared Devices (20 of 87)

Showing 20 most recent of 87 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K261898Triathlon® Knee System; Triathlon® Hinge Knee System; Scorpio® Total Knee SystemHowmedica Osteonics Corp. dba Stryker OrthopaedicsAug 6, 2026SESE
K252898Triathlon® Tritanium® Asymmetric Patella; Triathlon® Tritanium® Symmetric Patella; Triathlon® Symmetric Patella; Triathlon® Asymmetric Patella; Scorpio® Universal Dome Patella; Triathlon® Hinge BumperHowmedica Osteonics Corp., Dba Stryker OrthopaedicsDec 15, 2025SESE
K252303Stem Extension Line (USTAR II System)United Orthopedic CorporationAug 22, 2025SESE
K251665Triathlon® Hinge Knee SystemHowmedica Osteonics Corp., Dba Stryker OrthopaedicsJul 25, 2025SESE
K242871ATTUNE™ Revision Hinge KneeDepuy Ireland UCNov 21, 2024SESE
K240043EVOLUTION® Hinge Knee System;GUARDIAN™ limb Salvage System;DCW Modular Distal Femoral System;REPIPHYSIS™ Limb Salvage System;EVOLUTION® MP Total Knee System; EVOLUTION® MP Total Knee System; EVOLUTION® MP Adaptive CS Insert; EVOLUTION® MP Adaptive PS Tibial Insert; EVOLUTION® MP CS/CR Porous Femur/EVOLUTION® Adaptive CS and PS Inserts; EVOLUTION® Revision CCK System; ADVANCE® Double High Insert; ADVANCE® A-CLASS® Tibial Insert; ADVANCE® Knee System; ADVANCE® Ultra-Congruent Tibial InseMicroport Orthopedics, Inc.Apr 1, 2024SESE
K233980ATTUNE Total Knee System, ATTUNE Cementless Knee System, LPS Limb Preservation System, Sigma High Performance (HP) Partial Knee SystemDepuy Ireland UCMar 21, 2024SESE
K230563EVOLUTION® Hinge Knee SystemMicroport Orthopedics, Inc.Sep 27, 2023SESE
K230416Triathlon® Hinge Knee System; Triathlon® Revision Insert X3®StrykerMay 19, 2023SESE
K223069Modular Rotating Hinge Knee Systems and Compatible ComponentsHowmedica Osteonics Corp., Dba Stryker OrthopaedicsApr 21, 2023SESE
K223528Triathlon® Hinge Knee SystemHowmedica Osteonics Corp., Dba Stryker OrthopaedicsJan 20, 2023SESE
K220628LINK Endo-Model EVO Knee SystemWaldemar Link GmbH & Co. KGMay 3, 2022SESE
K211677ELEOS Limb Salvage SystemOnkos SurgicalJul 28, 2021SESE
K211768LINK Endo-Model Knee System, Femoral Segments (Augments), UHMWPEWaldemar Link GmbH & Co. KGJun 30, 2021SESE
K210010GMK Revision & Hinge Extension - TiNbN CoatingMedacta International S.A.Mar 2, 2021SESE
K192798Zimmer Segmental SystemZimmer, Inc.Dec 10, 2020SESE
K190181Instruments for LINK MEGASYSTEM-C FamilyLinkBio Corp.Oct 25, 2019SESE
K191779Attune Revision LPS InsertsDepuy(Ireland)Oct 8, 2019SESE
K190100USTAR II SystemUnited Orthopedic CorporationSep 23, 2019SESE
K172347GMK Hinge, GMK RevisionMedacta International S.A.Nov 1, 2017SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...