FRC · Indicator, Biological Sterilization Process

General Hospital · 21 CFR 880.2800 · Class 2

Overview

Product CodeFRC
Device NameIndicator, Biological Sterilization Process
Regulation21 CFR 880.2800
Device ClassClass 2
Review PanelGeneral Hospital
3rd-Party ReviewableYes

Identification

Biological sterilization process indicator: A device intended for use by a health care provider to accompany products being sterilized through a sterilization procedure and to monitor adequacy of sterilization. The device consists of a known number of microorganisms, of known resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent growth or failure of the microorganisms to grow under suitable conditions indicates the adequacy of sterilization. Physical/chemical sterilization process indicator: A device intended for use by a health care provider to accompany products being sterilized through a sterilization procedure and to monitor one or more parameters of the sterilization process. The adequacy of the sterilization conditions as measured by these parameters is indicated by a visible change in the device.

Classification Rationale

Class II (performance standards).

Recent Cleared Devices (20 of 206)

Showing 20 most recent of 206 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K260766Celerity 5 HP Biological Indicator (LCB052)STERIS CorporationApr 8, 2026SESE
K252680Celerity™ 20 HP Biological IndicatorSTERIS CorporationSep 24, 2025SESE
K251122Terragene® Bionova® BT20 Biological IndicatorTerrageneAug 4, 2025SESE
K251452Celerity 5 HP Biological Indicator (LCB052); Celerity 5 HP Challenge Pack (LCB059); Celerity 20 HP Biological Indicator (LCB044); Celerity 20 HP Challenge Pack (LCB045)SterisJun 6, 2025SESE
K250061Celerity IncubatorSTERIS CorporationFeb 6, 2025SESE
K250044Celerity 5 HP Biological Indicator (LCB052); Celerity 5 HP Challenge Pack (LCB059); Celerity 20 HP Biological Indicator (LCB044); Celerity 20 HP Challenge Pack (LCB045)STERIS CorporationFeb 6, 2025SESE
K2435013M™ Attest™ Super Rapid Steam Extended Cycle Clear Challenge Pack 1492PCDE; 3M™ Attest™ Auto-reader 490; 3M™ Attest™ Auto-reader 490H; 3M™ Attest™ Mini Auto-reader 490M3M CompanyJan 28, 2025SESE
K242453Terragene® Bionova® Photon Process Challenge Device with unique-point integrator (PCD225-2);Terragene® Bionova® Photon Process Challenge Device with moving-front integrator (PCD225-C)Terragene S.A.Dec 12, 2024SESE
K2425383M™ Attest™ Super Rapid Readout Biological Indicator 1493; 3M™ Attest™ Super Rapid Steam Gravity Clear Challenge Pack 1493PCDG; 3M™ Attest™ Auto-reader 490; 3M™ Attest™ Auto-reader 490H; 3M™ Attest™ Mini Auto-reader 490M3M CompanyNov 25, 2024SESE
K2419593M™ Attest™ Super Rapid Steam Clear Challenge Pack (1492PCD); 3M™ Attest™ Auto-reader (490); 3M™ Attest™ Auto-reader (490H); 3M™ Attest™ Mini Auto-reader (490M)3M CompanyOct 18, 2024SESE
K231383Terragene® Bionova® Self-Contained Biological Indicator (BT95), Terragene® Bionova® Self-Contained Biological Indicator (BT96), Terragene® Chemdye® Chemical Process Indicator (CD42), Terragene® Cintape® Chemical Process Indicator Tape (CT40)Terragene S.A.Sep 18, 2024SESE
K2417103M™ Attest™ Super Rapid Readout Biological Indicator 1492V; 3M™ Attest™ Auto-reader 490; 3M™ Attest™ Auto-reader 490H; 3M™ Attest™ Mini Auto-reader 490M3M CompanySep 12, 2024SESE
K2415423M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack 1295PCD (1295PCD)3M CompanyJun 27, 2024SESE
K2407173M™ Attest™ Rapid Readout Biological Indicator 1295 and 3M™ Attest™ Vaporized Hydrogen Peroxide Tri-Metric Chemical Indicator 1348/1348E3M CompanyJun 27, 2024SESE
K2338143M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack (1295PCD); 3M™ Attest™ Auto-reader (490); 3M™ Attest™ Auto-reader (490H); 3M™ Attest™ Mini Auto-reader (490M)3M CompanyMar 15, 2024SESE
K233681ConFirm 20 Minute IncubatorSTERIS CorporationDec 15, 2023SESE
K231490Celerity 20 HP Biological Indicator; VERIFY V24 Self-Contained Biological IndicatorSTERIS CorporationAug 7, 2023SESE
K223717Celerity 5 HP Biological Indicator; Celerity 5 HP Challenge PackSTERIS CorporationJun 15, 2023SESE
K223715Celerity IncubatorSTERIS CorporationJun 15, 2023SESE
K223023Terragene Bionava SCBI (BT96), Terragene Bionova Reader Incubators (IC10/20FRLCD, Mini-bio), Terragene Chemdye (CD42), Terragene Cintape (CT40)Plasmapp Co,., Ltd.May 9, 2023SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.