ROCKWELL MEDICAL SUPPLY,LLC. BICARBONATE SOLUTION CONCENTRATES FOR BICARBONATE DIALYSIS
Device Facts
| Record ID | K971053 |
|---|---|
| Device Name | ROCKWELL MEDICAL SUPPLY,LLC. BICARBONATE SOLUTION CONCENTRATES FOR BICARBONATE DIALYSIS |
| Applicant | International Medical Products, Inc. |
| Product Code | KPO · Gastroenterology, Urology |
| Decision Date | Jun 16, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.5820 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Rockwell Medical Supply, LLC. Bicarbonate Solution Concentrates for Bicarbonate Dialysis are indicated for use in acute and chronic hemodialysis and to be used with the appropriate hemodialysis machine / monitor.
Device Story
Bicarbonate solution concentrates are chemical components used in hemodialysis procedures. The device is intended for use in clinical settings by trained healthcare professionals during acute or chronic hemodialysis. The solution is utilized by the hemodialysis machine to prepare the dialysate bath, which facilitates the removal of waste products and excess fluids from the patient's blood via a dialyzer. The healthcare provider monitors the dialysis process and machine parameters to ensure patient safety and therapeutic efficacy. The device provides the necessary chemical environment for bicarbonate-buffered dialysis, which helps maintain acid-base balance in patients with renal failure.
Clinical Evidence
No clinical data provided; substantial equivalence is based on the established nature of bicarbonate solution concentrates for hemodialysis.
Technological Characteristics
Chemical solution concentrate for hemodialysis; functions as a buffer component in dialysate preparation. Class II device (21 CFR 876.5820).
Indications for Use
Indicated for patients requiring acute or chronic hemodialysis treatment using compatible hemodialysis machines/monitors.
Regulatory Classification
Identification
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.
Related Devices
- K012547 — HEMO-LYTE HEMODIALYSIS GRADE SODIUM BICARBONATE SOLUTION · Di-Chem, Inc. · Jan 18, 2002
- K240920 — HemoCare Bicarbonate Concentrate Set (BCS) · Deka Research and Development · Jul 12, 2024
- K071387 — FRESENIUS NATURALYTE SODIUM BICARBONATE LIQUID CONCENTRATE, MODEL 08-4000-LB · Fresenius Medical Care North America · Jun 15, 2007
- K012328 — HEMO-LYTE HEMODIALYSIS GRADE SODIUM BICARBONATE POWDER · Di-Chem, Inc. · Jan 18, 2002
- K072760 — SOLCART B · B. Braun Medizintechnologie GmbH · Jan 29, 2008