NITRA-TOUCH POWDER-FREE NITRILE MEDICAL EXAMINATION GLOVE
K965095 · Ansell Edmont Industrial, Inc. · LZA · Apr 22, 1997 · General Hospital
Device Facts
Record ID
K965095
Device Name
NITRA-TOUCH POWDER-FREE NITRILE MEDICAL EXAMINATION GLOVE
Applicant
Ansell Edmont Industrial, Inc.
Product Code
LZA · General Hospital
Decision Date
Apr 22, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.6250
Device Class
Class 1
Intended Use
Nitra-Touch™ examination gloves are disposable device intended for medical purposes that is worn on the examiners hand to prevent contamination between patient and examiner.
Device Story
Nitra-Touch™ is a disposable nitrile examination glove; worn by healthcare examiners to prevent cross-contamination between patient and examiner. Device provides barrier protection; features high puncture resistance (8x greater than vinyl, 2x greater than competitive nitrile) and chemical resistance to glutaraldehyde. Used in clinical settings; operated by healthcare professionals. Output is physical barrier protection; affects clinical decision-making by ensuring sterile/clean environment during patient examinations.
Clinical Evidence
No clinical data. Bench testing only. Performance verified via ASTM D 3578 (dimensions, physical properties), ASTM D 5151 (freedom from holes), ASTM F739-91 (glutaraldehyde resistance), and biocompatibility studies (primary skin irritation in rabbits, guinea pig sensitization).
Technological Characteristics
Nitrile film material. Dimensions and physical properties meet ASTM D 3578 (except ultimate elongation: 500% original, 400% aged). Puncture resistance 1625 lbf/in (ASTM D 120-87). Tensile strength 17.1 MPa. Powder-free (<2 mg residue). Biocompatible.
Indications for Use
Indicated for use as a patient examination glove to prevent contamination between patient and examiner.
Regulatory Classification
Identification
A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.
Related Devices
K213107 — Powder Free Blue Nitrile Examination Gloves · Novid Ppe Sdn. Bhd. · Feb 17, 2022
K192104 — Medline Sterile Power-Free Nitrile Examination Gloves - Blue (Test for Use with Chemotherapy Drugs) · Medline Industries, Inc. · Dec 23, 2019
K193581 — Non-Sterile, Powder Free Nitrile Exam Glove Tested for use with Chemotherapy Drugs - Lilac, Non-Sterile, Powder Free Nitrile Exam Glove Tested for use with Chemotherapy Drugs - Orchid, Non-Sterile, Powder Free Nitrile Exam Glove Tested for use with Chemotherapy Drugs - Oyster · Sri Trang Gloves (Thailand) Public Company Limited · Mar 20, 2020
K210578 — Medical Nitrile Examination Gloves (Power free, Blue) · Jiangxi Hongda Medical Equipment Group , Ltd. · Jul 10, 2021
K030075 — NITRILE POWDER-FREE MEDICAL EXAMINATION GLOVE (BLUE) (TEXTURED AND NON-TEXTURED) · Best Manufacturing Company-Distribution Center · Mar 5, 2003
Submission Summary (Full Text)
{0}
Ansell Edmont Industrial
Ansell Edmont Industrial Inc.
400 Northridge Rd.
Suite 800
Atlanta, Georgia 30350
Telephone: (770) 641-1900
FAX: (770) 641-1988
K965055
Nitra-Touch™
Checklist
Section 21.0
[1] 510 (k) Summary
[2] Ansell Edmont Industrial, Inc.
400 Northridge Road, Suite 800
Atlanta, GA 30350
APR 22 1997
Telephone: 770-641-1900
Fax: 770-641-1988
Contact: Mike W. Hagans
Telephone: 614-623-3595
Fax: 614-623-3515
December 12, 1996
[3] Trade Name: Nitra-Touch™
Common Name: Exam Gloves
Classification Name: Patient Examination Glove
[4] Nitra-Touch™ examination gloves, meet all of the requirements of ASTM D 3578 with the following variation.
[5] Nitra-Touch™ examination gloves meet all the current specifications for ASTM D 3578 Rubber Examination Gloves except for the ultimate elongation percentage before and after aging.
[6] Nitra-Touch™ examination gloves are disposable device intended for medical purposes that is worn on the examiners hand to prevent contamination between patient and examiner.
[7] Nitra-Touch™ examination gloves are summarized with the following technological characteristics compared to ASTM or equivalent standards.
| Characteristics | Standard |
| --- | --- |
| Dimensions | Meets ASTM D 3578 |
| Physical Properties | Meets ASTM D 3578 |
| Except Ultimate Elongation meets specifications described under Attachment II | Original Ultimate Elongation 500% minimum
Aged Ultimate Elongation 400% minimum |
Revised 2/21/97
{1}
Ansell Edmont
Industrial
Ansell Edmont Industrial Inc.
400 Northridge Rd.
Suite 800
Atlanta, Georgia 30350
Telephone: (770) 641-1900
FAX: (770) 641-1988
Nitra-Touch™
Freedom from holes
Meets ASTM D 3578
Meets ASTM D 5151
Powder-Free
Meets described test in Attachment V
Not more than 2 mg residue by mass.
Tensile Strength 60% higher than vinyl (synthetic) examination gloves
Puncture resistance of Nitra-Touch™ is eight (8) times greater than vinyl and nearly twice that of competitive nitrile gloves
Nitrile film provides excellent chemical resistance to glutaraldehyde.
Tensile Strength MPa
ASTM D 5250
ASTM D 3578
Vinyl = 10.5
Nitra-Touch™ = 17.1
Puncture lbf/in
ASTM D 120-87
Nitra-Touch™ = 1625
Blue Nitrile = 929
Vinyl (Synthetic) = 184
Glutaraldehyde Resistance
ASTM T F739-91
Source: TRI/Environmental, Inc.
Breakthrough Time = >480
Permeation Rate = <0.013 µg/cm²* min
Biocompatibility
Primary Skin Irritation in Rabbits
Guinea Pig Sensitization
Passes
Passes
[8] The performance test data of the non clinical tests are the same as mentioned immediately above.
[9] Clinical data is not needed for medical gloves or for most devices cleared by the 510(k) process.
[10] It is concluded that Nitra-Touch™ examination gloves are as safe, as effective, and perform as well as the glove performance standards referenced in Section 7 above and therefore meet:
ASTM listed standards,
FDA hole requirements, and
labeling claims for the product.
[11] This summary will include any other information reasonably deemed necessary by The FDA.
Revised 2/21/97
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.