PORTAREM-3000, PFS-6000
Device Facts
| Record ID | K964340 |
|---|---|
| Device Name | PORTAREM-3000, PFS-6000 |
| Applicant | Starkey Laboratories, Inc. |
| Product Code | EWO · Ear, Nose, Throat |
| Decision Date | Jan 10, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 874.1050 |
| Device Class | Class 2 |
Intended Use
The portaREM-3000, PFS-6000 is a portable hearing aid dispensing system which allows the Hearing Health Care Professional to test hearing aids to IEC/ANSI standards. It also allows for Real Ear testing, and In Situ Audiometry via the use of the probe microphone, and offers a 2cc coupler conversion in which the 2cc coupler response desired can be determined from the audiogram. Standard puretone measurement is also available. With the PFS software, which will be standard with PFS-6000 and optional for the pR-3000, prescriptive formulas, matrix and hearing aid selection, order form printing, along with other options described in the user manual are available.
Device Story
Portable hearing aid dispensing system for clinical use by hearing health care professionals. Inputs: probe microphone signals (Real Ear/In Situ), puretone audiometry, and hearing aid test chamber measurements. System performs IEC/ANSI standard testing, intermodulation distortion analysis, and 2cc coupler conversions. PFS software provides prescriptive fitting formulas (NAL, POGO I/II, 1/2 Gain, 1/3 Gain, Berger), matrix selection, and order printing. Output: visual data on 4.7" LCD/external monitor, hard copy via built-in thermoprinter, and hearing aid performance metrics. Benefits: enables precise hearing aid calibration, fitting, and verification of performance against prescriptive targets.
Clinical Evidence
Bench testing only; system complies with IEC 601 and FCC Part 15 Class B standards. No clinical trial data provided.
Technological Characteristics
2-channel system; 4.7" 640x480 color LCD; built-in thermoprinter; 3.5" floppy drive; 2x RS-232 ports; 6W loudspeaker (50-15,000 Hz). Measurement range: 42-15,600 Hz; dynamic range 130 dB; accuracy ±0.2 dB. Electrical THD < 0.01%. Power: 110/220V AC. Complies with IEC 601 and FCC Part 15 Class B.
Indications for Use
Indicated for hearing health care professionals to perform hearing aid testing, real ear measurements, in situ audiometry, and hearing aid fitting/selection for patients requiring hearing aid calibration and adjustment.
Regulatory Classification
Identification
An audiometer or automated audiometer is an electroacoustic device that produces controlled levels of test tones and signals intended for use in conducting diagnostic hearing evaluations and assisting in the diagnosis of possible otologic disorders.
Related Devices
- K973320 — ARTICULATE FITTING SYSTEM · Decibel Instruments, Inc. · Nov 25, 1997
- K113831 — PRIMUS HEARING INSTRUMENT TEST UNIT · Auditdata A/S · Apr 19, 2012
- K110286 — GN OTOMETRICS TYPE 1053 FREEFIT · Gn Otometrics A/S · Apr 28, 2011
- K973880 — SONIX HEARING AID FITTING AND PROGRAMMING SYSTEM · Sonix Technologies, Inc. · Jan 12, 1998
- K103298 — ACAM 5 AUDIOMETER SYSTEM · Acousticon GmbH · Apr 8, 2011