PHONAK MICROLINK, PERSONAL FM RECEIVER
Device Facts
| Record ID | K964035 |
|---|---|
| Device Name | PHONAK MICROLINK, PERSONAL FM RECEIVER |
| Applicant | Phonak, Inc. |
| Product Code | ESD · Ear, Nose, Throat |
| Decision Date | Dec 4, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 874.3300 |
| Device Class | Class 1 |
Indications for Use
To receive FM transmission from a same channel transmitter/microphone and feed it to the hearing aid. An example of such use would be a lecture hall setting with user receiving direct input from the person lecturing.
Device Story
Personal FM receiver; connects to Phonak BTE hearing instruments via audio input; receives FM signals from same-channel transmitter/microphone; feeds audio directly to hearing aid; powered by hearing aid battery; features FM-only or FM/M input selection switch; used in settings like lecture halls to improve speech intelligibility; operated by hearing aid user; delivered pre-assembled to dispensers or schools.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Personal FM receiver; 216 MHz frequency band; complies with FCC Part 90 rules; powered by hearing aid battery; audio input connection to BTE hearing instruments; manual input selection switch.
Indications for Use
Indicated for individuals using Phonak BTE hearing instruments requiring direct FM audio input for improved signal reception in environments like lecture halls.
Regulatory Classification
Identification
An air-conduction hearing aid is a wearable sound-amplifying device intended to compensate for impaired hearing that conducts sound to the ear through the air. An air-conduction hearing aid is subject to the requirements in § 800.30 or § 801.422 of this chapter, as applicable. The air-conduction hearing aid generic type excludes the group hearing aid or group auditory trainer, master hearing aid, and the tinnitus masker, regulated under §§ 874.3320, 874.3330, and 874.3400, respectively.
Related Devices
- K961143 — TELEX SELECT 2-40 WITH ADAPTIVE COMPRESSION S2-40 · Telex Communications, Inc. · May 7, 1996
- K974287 — FM RECEIVER - AUDITORY TRAINER · Phonic Ear, Inc. · Feb 10, 1998
- K970974 — WILLIAMS SOUND, PERSONAL FM SYSTEM, HEARING HELPER · Williams Sound, LLC · May 2, 1997
- K982683 — TELEX SELECT 1-40 WITH ADAPTIVE COMPRESSION · Telex Communications, Inc. · Oct 6, 1998
- K970687 — WILLIAMS SOUND, PERSONAL FM, HEARING HELPER · Williams Sound, LLC · May 2, 1997