A4907 LENS CLEANING SHEATH

K961860 · Olympus America, Inc. · HET · Aug 29, 1996 · Obstetrics/Gynecology

Device Facts

Record IDK961860
Device NameA4907 LENS CLEANING SHEATH
ApplicantOlympus America, Inc.
Product CodeHET · Obstetrics/Gynecology
Decision DateAug 29, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 884.1720
Device ClassClass 2

Indications for Use

The A4907 Lens Cleaning Sheath has been specifically designed to be used with the Olympus A4908 Valve and LTF-V OES V Laparo-Thoraco Videoscope to clean of the objective lens surface.

Device Story

Lens cleaning sheath; attaches to Olympus LTF-V OES Laparo-Thoraco Videoscope; provides irrigation and suction capabilities; enables cleaning of objective lens surface during endoscopic procedures; used by clinicians in surgical/endoscopic settings; maintains clear visualization; improves procedural efficiency.

Clinical Evidence

No clinical data; bench testing only.

Technological Characteristics

Accessory for endoscope; provides irrigation and suction channels for lens cleaning; compatible with Olympus A4908 Valve and LTF-V OES Laparo-Thoraco Videoscope.

Indications for Use

Indicated for cleaning the objective lens surface of the Olympus LTF-V OES Laparo-Thoraco Videoscope during endoscopic procedures.

Regulatory Classification

Identification

A gynecologic laparoscope is a device used to permit direct viewing of the organs within the peritoneum by a telescopic system introduced through the abdominal wall. It is used to perform diagnostic and surgical procedures on the female genital organs. This generic type of device may include: Trocar and cannula, instruments used through an operating channel, scope preheater, light source and cables, and component parts.

Predicate Devices

Submission Summary (Full Text)

{1} K961860 AUG 29 1996 510 (k) SUMMARY # Olympus A4907 Lens Cleaning Sheath | Device Name: | Olympus A4907 Lens Cleaning Sheath | | --- | --- | | Common/Usual Name: | Lens Cleaning Tube | | Classification Name: | Endoscope and Accessories 21 CFR 876 1500, Class II | | Predicate Devices: | Cook Lens Cleaner (Unknown) Wiest Optic Shaft (Unknown) DevMed Lap wash (Unknown) | | Submitted By: (Contact Person) | Subhash Patel Olympus America Inc. Endoscope Division Two Corporate Center Drive Melville, New York 11747-3157 (516) 844-5481 | | Summary Preparation Date: | May 8, 1996 | ## Statement of Intended Use: The A4907 Lens Cleaning Sheath has been specifically designed to be used with the Olympus A4908 Valve and LTF-V OES V Laparo-Thoraco Videoscope to clean of the objective lens surface. ## Device Description The A4907 Lens Cleaning Sheath has been specifically designed for use with the Olympus A4908 Valve and LTF-V OES Laparo-Thoraco Videoscope. It will be included in the standard set of LTF-V Laparo-Thoraco Videoscope and will also be marketed separately. When connected to the main body of LTF-V videoscope, it offers lens cleaning, irrigation, and suction capabilities to the user during endoscopic procedures. It is substantially equivalent in design, intended use, and method of operation to the “Lens Cleaner” manufactured by Cook, “Optic Shaft” manufactured by Wiest, and “Lap Wash System” manufactured by DevMed Group Inc. ## General Safety When compared with the predicate devices, Olympus A4907 Lens Cleaning Sheath does not incorporate any significant change in intended use, method of operation, material, or design that could affect the safety or effectiveness of the subject device. 41
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...