GE ADVANTAGE WINDOWS REVIEW WORKSTATION
Device Facts
| Record ID | K960613 |
|---|---|
| Device Name | GE ADVANTAGE WINDOWS REVIEW WORKSTATION |
| Applicant | GE Medical Systems |
| Product Code | LLZ · Radiology |
| Decision Date | Apr 30, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 892.2050 |
| Device Class | Class 2 |
Intended Use
The GE Advantage Windows Review Workstation is a two dimensional review station which allows selection and review of DICOM images from Computed Tomography (CT), Magnetic Resonance (MR), X-Ray (XR), Computed Radiography (CR) and Secondary Capture (SC) modalities.
Device Story
Workstation for review of medical images; inputs DICOM data from CT, MR, XR, CR, and SC modalities via Ethernet or ATM network; hardware platform utilizes Sun Microsystems Sparc 4, 5, 20, or UltraSparc Unix architecture; software application enables image selection and 2D visualization on color landscape or high-resolution monochrome monitors; used by radiologists and clinicians in clinical settings; facilitates diagnostic review and clinical decision-making by providing access to multi-modality imaging data.
Clinical Evidence
Bench testing only. System design verification tests performed to ensure conformance with design specifications; additional validation conducted to assess user satisfaction.
Technological Characteristics
Hardware: Sun Microsystems Sparc 4, 5, 20, or UltraSparc Unix workstation; 32-128 MB RAM; 1-4 GB mass storage; Ethernet/ATM networking; color landscape or high-resolution monochrome monitors. Software: GE Advantage Windows application. Connectivity: DICOM standard.
Indications for Use
Indicated for clinicians requiring selection and review of 2D DICOM images from CT, MR, XR, CR, and SC modalities.
Regulatory Classification
Identification
A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.
Special Controls
*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).
Predicate Devices
- Advantage CT/MR Radiology Diagnostic Workstation (K913770)
- Advantage Windows Diagnostic X-Ray Workstation (K942120)
Related Devices
- K020483 — ADVANTAGE WORKSTATION 4.1 · GE Medical Systems · Feb 28, 2002
- K063470 — AYCAN WORKSTATION OSIRIX · Aycan Digitalsysteme GmbH · Jan 5, 2007
- K022970 — AMICAS LIGHT BEAM WORKSTATION, MODEL 1.0 · Amicas, Inc. · Nov 22, 2002
- K962589 — AURORA DIAGNOSTIC WORKSTATION · Aurora Technology, Inc. · Sep 20, 1996
- K103546 — AYCAN WORKSTATION OSIRIX PRO · Aycan Digitalsysteme GmbH · Mar 17, 2011