ESSENCE GUIDEWIRE
Device Facts
| Record ID | K955637 |
|---|---|
| Device Name | ESSENCE GUIDEWIRE |
| Applicant | Cordis Neurovascular, Inc. |
| Product Code | DQX · Cardiovascular |
| Decision Date | Mar 11, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 870.1330 |
| Device Class | Class 2 |
Intended Use
The ESSENCE™ Guidewires are intended for the introduction and positioning of catheters and interventional devices within the peripheral, coronary and neurovascular systems. The guidewires have a soft, flexible tip and may be used with intravascular devices what are indicated for use with such guidewires.
Device Story
Steerable guidewire; soft, flexible tip; facilitates introduction/positioning of catheters and interventional devices; used in peripheral, coronary, and neurovascular systems; operated by clinicians during interventional procedures; provides mechanical support/guidance for intravascular devices.
Clinical Evidence
No clinical data; biocompatibility testing performed.
Technological Characteristics
Stainless steel steerable guidewire; soft, flexible tip; mechanical device; no software or energy source.
Indications for Use
Indicated for introduction and positioning of catheters and interventional devices within peripheral, coronary, and neurovascular systems.
Regulatory Classification
Identification
A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel.
Special Controls
*Classification.* Class II (special controls). The device, when it is a torque device that is manually operated, non-patient contacting, and intended to manipulate non-cerebral vascular guide wires, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.
Predicate Devices
- Cordis Endovascular Systems, Inc. Instinct® Steerable Guidewire (K930982)
- Cordis Corporation Reflex Steerable Guidewire (K905432)
- Target Therapeutics Dasher Guidewire (K914030)
Related Devices
- K963214 — CORDIS ST STEERABLE GUIDEWIRE · Cordis Corp. · Nov 13, 1996
- K100470 — GTX 12 GIDEWIRE · Medtronic, Inc. · Apr 21, 2010
- K202522 — Synchro SELECT Guidewire · Stryker Neurovascular · Sep 25, 2020
- K992237 — MEDTRONIC GT2 FUSION GUIDE WIRES · Medtronic Vascular · Sep 9, 1999
- K140695 — COUGAR GUIDEWIRE, ZINGER GUIDWIRE, THUNDER GUIDEWIRE, PROVIA GUIDEWIRE, INTUITION GUIDEWIRE · Medtronic, Inc. · Jun 12, 2014