FIRST PICC INTRODUCER CATHETER

K954906 · Becton Dickinson Vascular Access, Inc. · DYB · Apr 8, 1996 · Cardiovascular

Device Facts

Record IDK954906
Device NameFIRST PICC INTRODUCER CATHETER
ApplicantBecton Dickinson Vascular Access, Inc.
Product CodeDYB · Cardiovascular
Decision DateApr 8, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1340
Device ClassClass 2

Indications for Use

The intended use is to facilitate the placement of other devices such as guidewires, central venous catheters, peripherally inserted central venous catheters, and probes in the vascular system.

Device Story

FIRST PICC™ introducer catheter; short-term, single-use device. Inserted into vascular system over needle; designed to split and peel away after use. Facilitates placement of guidewires, central venous catheters, PICCs, and probes. Used by clinicians in clinical settings. Benefits patient by enabling secure, temporary vascular access for secondary device insertion.

Clinical Evidence

Bench testing only.

Technological Characteristics

Short-term, single-use intravascular catheter. Splittable design. Various gauges and lengths. Sterile.

Indications for Use

Indicated for patients requiring vascular access for the placement of guidewires, central venous catheters, peripherally inserted central venous catheters, and probes.

Regulatory Classification

Identification

A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.

Predicate Devices

Submission Summary (Full Text)

{1} K954906 # SUMMARY OF SAFETY AND EFFICACY A. The submitter’s name, address, telephone number, contact person, and date of preparation. Submitted by Becton Dickinson Vascular Access, 9450 South State Street, Sandy, UT 84070. Contact: C. J. Welle. Telephone: 801-565-2535. Prepared: October 24, 1995. B. The name of the device including trade or proprietary name if applicable, the common or usual name, and the classification name. Name: Introducer Catheter Brand: FIRST PICC™ Common Name: Introducer Catheter Classification Name: Intravascular Catheter (80 FOZ) C. An identification of the predicate or legally marketed device to which substantial equivalence is claimed: Predicate Device: The Becton Dickinson Vascular Access INSYTE® brand and SPLIT SECOND® brand introducer catheters and the Teleflex, Inc. Percutaneous Introducer Set. D. A description of the device that is the subject of the Premarket Notification submission. The subject catheter is a short term, single use introducer catheter of various gauges and lengths which is designed to split and peel away following use. It is inserted into the vascular system over a needle. E. Statement of intended use of the device. The intended use is to facilitate the placement of other devices such as guidewires, central venous catheters, peripherally inserted central venous catheters, and probes in the vascular system. F. A statement of how the technological characteristics compare to those of the predicate or legally marketed device identified in section C above. The proposed catheter differs from the INSYTE® brand introducer catheter in that it is splittable; however, the intended use is the same. It is similar to the SPLIT SECOND® brand introducer catheter and the Teleflex, Inc. Percutaneous Introducer Set in that both are splittable and both are introducer catheters. 001 86
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...