VitalSigns 1-Lead Holter (VSH101)

K243003 · VitalSigns Technology Co., Ltd. · DXH · Jun 17, 2025 · Cardiovascular

Device Facts

Record IDK243003
Device NameVitalSigns 1-Lead Holter (VSH101)
ApplicantVitalSigns Technology Co., Ltd.
Product CodeDXH · Cardiovascular
Decision DateJun 17, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.2920
Device ClassClass 2

Intended Use

The VSH101 is designed to record, transmit, and store single channel electrocardiogram (ECG) data via Bluetooth communication to compatible Bluetooth enabled devices. The device is intended for use by healthcare professionals, individuals with known or suspected cardiac conditions, and health-conscious users. The ECG data serves as a supplementary source of patient information and is not intended for automated analysis.

Device Story

VitalSigns 1-Lead Holter (VSH101) is an ambulatory ECG monitoring system consisting of a chest-worn electrode patch (VSP101), an ECG recorder host (VSH101), and a mobile application (VSHealth). The device captures single-channel ECG signals via the electrode patch, which are transmitted via Bluetooth Low Energy to the VSHealth app for display, recording, and storage. The system supports up to 24 hours of continuous recording in home or clinical environments. It is operated by healthcare professionals or patients. The output is raw ECG data intended for manual interpretation by a clinician to supplement patient information; the device does not perform automated analysis. The system provides a supplementary diagnostic tool for cardiac monitoring.

Clinical Evidence

Bench testing only. No clinical data provided. Testing included biocompatibility (cytotoxicity, irritation, sensitization), electrical safety (IEC 60601-1, IEC 60601-1-11), electromagnetic compatibility (IEC 60601-1-2), performance testing (IEC 60601-2-47, ANSI/AAMI EC12), and software/cybersecurity validation.

Technological Characteristics

Single-channel ECG recorder; Bluetooth Low Energy (2402–2480 MHz) connectivity. Electrode patch uses 3M Single-Coated Medical Tan Elastic Nonwoven Tape and AmGel AG600 Series Sensing Hydrogels. Powered by 3.7V/160mAh rechargeable lithium battery. Complies with IEC 60601-1, IEC 60601-1-2, IEC 60601-1-11, IEC 60601-2-47, and ANSI/AAMI EC12. Software validated per IEC 62304.

Indications for Use

Indicated for patients 21 years of age or older with known or suspected cardiac conditions. Contraindicated for patients with chronic disease, polyester allergies, pregnancy, breastfeeding, infants/children, patients with pacemakers or ICDs, and patients undergoing defibrillation or AED rescue.

Regulatory Classification

Identification

A telephone electrocardiograph transmitter and receiver is a device used to condition an electrocardiograph signal so that it can be transmitted via a telephone line to another location. This device also includes a receiver that reconditions the received signal into its original format so that it can be displayed. The device includes devices used to transmit and receive pacemaker signals.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION June 17, 2025 VitalSigns Technology Co., Ltd. Leon Chuang Chief of Technology Officer 3F., No. 153, Ziqiang S. Rd., Zhubei City Hsinchu County, 302042 Taiwan Re: K243003 Trade/Device Name: VitalSigns 1-Lead Holter (VSH101) Regulation Number: 21 CFR 870.2920 Regulation Name: Telephone electrocardiograph transmitter and receiver Regulatory Class: Class II Product Code: DXH Dated: May 23, 2025 Received: May 23, 2025 Dear Leon Chuang: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1} K243003 - Leon Chuang Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory- {2} K243003 - Leon Chuang Page 3 assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Jennifer W. Shih -S Jennifer Kozen Assistant Director Division of Cardiac Electrophysiology, Diagnostics, and Monitoring Devices Office of Cardiovascular Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. Submission Number (if known) K243003 Device Name VitalSigns 1-Lead Holter (VSH101) Indications for Use (Describe) The VSH101 is designed to record, transmit, and store single channel electrocardiogram (ECG) data via Bluetooth communication to compatible Bluetooth enabled devices. The device is intended for use by healthcare professionals, individuals with known or suspected cardiac conditions, and health-conscious users. The ECG data serves as a supplementary source of patient information and is not intended for automated analysis. Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) # CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {4} VitalSigns K243003 # 510(K) Summary ## 1. Submitter | 510(K) Sponsor | VitalSigns Technology Co., Ltd | | --- | --- | | Address | 3F., No. 153, Ziqiang S. Rd., Zhubei City, Hsinchu County 302042, Taiwan (R.O.C.) | | Applicant | JIH-LIANG, JUANG | | Contact Information | TEL: +886-3-6682091 Mail: jl_juang@vsigntek.com | | Correspondent Person | JIH-LIANG, JUANG | | Contact Information | TEL: +886-3-6682091 Mail: jl_juang@vsigntek.com | | Date | 2025/05/23 | ## 2. Subject device | Device Name | VitalSigns 1-Lead Holter | | --- | --- | | Regulation Name | Telephone electrocardiograph transmitter and receiver | | Regulation Number | 21 CFR870.2920 | | Product Code | DXH | | 510(k) review | Cardiovascular | | Regulatory Class | Class II | ## 3. Predicate device | Device Name | eCordum™ Cardiac Monitor | | --- | --- | | Regulation Name | Telephone electrocardiograph transmitter and receiver | | Regulation Number | 21 CFR870.2920 | | Product Code | DXH | | 510(k) review | Cardiovascular | | Regulatory Class | Class II | | 510(k) number | K193296 | {5} VitalSigns K243003 # 4. Device Description ![img-0.jpeg](img-0.jpeg) ECG recorder host ![img-1.jpeg](img-1.jpeg) Bluetooth ![img-2.jpeg](img-2.jpeg) iOS APP VSHealth Figure-1 Illustration of VitalSigns 1-Lead Holter VitalSigns 1-Lead Holter is an ambulatory and Bluetooth-based wireless communication ECG measurement solution designed to allow users to record, store, transmit, and display single-channel ECG data. VitalSigns 1-Lead Holter consists of the following three components: (1) VS Electrode Patch "VSP101" (2) ECG Recorder Host "VSH101" (3) iOS APP "VSHealth" When the ECG Recorder Host "VSH101" is fully charged and connected wirelessly via Bluetooth to the iOS app "VSHealth", it can instantly obtain the user's ECG data. VSHealth assists in transmitting, displaying, recording, and storing ECG data. After the "VSH101" is fully charged, the device, through the VSHealth app, allows users to continuously use and record ECG data for 24 hours in their daily routines, whether at home or in a work environment. # 5. Intended Use/ Indication for Use The VSH101 is designed to record, transmit, and store single channel electrocardiogram (ECG) data via Bluetooth communication to compatible Bluetooth enabled devices. The device is intended for use by healthcare professionals, individuals with known or suspected cardiac conditions, and health-conscious users. The ECG data serves as a supplementary source of patient information and is not intended for automated analysis. Page 2 of 8 {6} VitalSigns K243003 # 6. Contraindications VSH101 is contraindicated for those patients with the following conditions: - Chronic Disease patients - Allergic to polyester patient - Pregnant women, breastfeeding women, infants or children - Patients with implanted pacemakers or implantable cardioverter defibrillators (ICDs). The device should not be used in the presence of these implants. - Patients during defibrillation or AED rescue. The device must be removed prior to such procedures. Caution: The ECG data acquired by the subject device is a non-traditional lead intended only for manual interpretation. # 7. Target Population This product is intended for use in patients 21 years of age or older. Page 3 of 8 {7} K243003 Page 4 of 8 | Device Name | VitalSigns 1-Lead Holter | eCordum™ Cardiac Monitor | Substantial equivalence of difference determination | | --- | --- | --- | --- | | Applicant | VitalSigns Technology Co., Ltd | eCordum, Inc. | -- | | 510(k) Number | K243003 | K193296 | -- | | Regulation Number | 21 CFR 870.2920 | 21 CFR 870.2920 | SE | | Product Code | DXH | DXH | SE | | Classification | Class II | Class II | SE | | Indication for use | The VSH101 is designed to record, transmit, and store single- channel electrocardiogram (ECG) data via Bluetooth communication to compatible Bluetooth enabled devices. The device is intended for use by healthcare professionals, individuals with known or suspected cardiac conditions, and health-conscious users. The ECG data serves as a supplementary source of patient information and is not intended for automated analysis. | The eCordum™ Cardiac Monitor is intended to record, transfer and store single- channel electrocardiogram (ECG) data via Bluetooth transmission to Bluetooth enabled devices. The monitor is intended for use by healthcare professionals, patients with known or suspected heart conditions and health-conscious individuals. The ECG data is intended to supplement other patient data and is not intended for automated analysis. The device has not been tested and it is not intended for pediatric use. | SE | | Number of ECG | 1 channel | 1 channel | SE | | Power source | Rechargeable Lithium battery pack 3.7V/160mAh/ 0.59Wh | Replaceable Coin Battery (CR2032) | Different The battery has been tested and met its pre- defined criteria, and it does not raise new issues of safety and effectiveness. | {8} K243003 Page 5 of 8 | Intended use environment | Healthcare and home environments | Healthcare | Similar Predicate device allows ambulatory use and by healthcare professionals. Although home use is not explicitly stated, the functional environment overlap supports similar use conditions | | --- | --- | --- | --- | | Communication Protocol | Bluetooth Low Energy (2402 – 2480 MHz) | Class II Bluetooth | Similar transmission type | | Data storage | 24 hours | Not provided | Different There is no change in the safety and effectiveness of the device. Performance is equivalent to IEC 60601-2-47 for all devices. | | Viewing software platform | Mobile app | Mobile app | SE | | Application/wear | Chest-based, single channel | Chest for ambulatory OTS electrodes | Similar region | | Electrodes | The VS Electrode Patch is composed of 3M™ Single-Coated Medical Tan Elastic Nonwoven Tape on Line and AmGel AG600 Series Sensing Hydrogels. Both materials are widely utilized in electrode applications. | Attachable standard ambulatory OTS electrodes with conductive gel. | Different The VS Electrode Patch has been tested in accordance with ANSI/AAMI EC12, confirming compliance with established safety and performance standards. The patch provides stable conductivity, low impedance, and biocompatibility. | {9} K243003 Page 6 of 8 | **Compliance standard** | IEC 60601-1 | IEC 60601-1 | **Similar** The predicate device does not reference ANSI/AAMI EC12 and IEC 60601-1-11. To address the required signal quality, evidence will be generated through the proposed performance verification protocol in this submission. | | --- | --- | --- | --- | | | IEC 60601-2-47 IEC 60601-1-11 IEC 10993-1 ANSI/AAMI EC12 FCC testing per part 15 | IEC 60601-1-2 IEC 60601-2-47 IEC 10993-1 FCC testing per part 15 | | The VitalSigns 1-Lead Holter has been compared with a predicate device. The subject device has the same indications for use, similar technology/mechanism of action, and similar safety and performance as the predicate device. Although there are some different specifications between two devices, the software validation, performance test and usability test have been completed to demonstrate that the differences between these parameters would not impact the safety and effectiveness of the subject device. The subject device has also undergone all safety and performance tests, and the results complied with the test requirements. Therefore, the difference between the subject device and the predicate device did not raise any problem of substantial equivalence. The subject device is substantially equivalent to the predicate device in intended use, safety and performance claims. Continued on the next page {10} VitalSigns K243003 # 9. Summary of Non-Clinical Testing The VitalSigns 1-Lead Holter meet all requirements for all design, biocompatibility, electrical, EMC safety and cybersecurity protection. The VitalSigns 1-Lead Holter pass all testing and supports the claims of substantial equivalence and safe operation. The VitalSigns 1-Lead Holter was designed and tested for compliance with the applicable clauses of the following standards and USFDA guidance: - ISO 10993-1 - IEC 60601-1 Note: VSH101 has been tested and complies with the requirements of Clause 8.5.5.2 – Energy reduction test. - IEC 60601-1-2 - IEC 60601-2-47 - IEC 60601-1-11 - IEC 62304 - ISO 14971 - IEC 62366-1 - ANSI/AAMI EC 12 - IEEE/ANSI C63.27 - USFDA Guidance, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process" - USFDA Guidance, Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions. - USFDA Guidance for the Content of Premarket Submissions for Software Contained in Medical Device. ## Biocompatibility test - Biological evaluation of medical device - In vitro cytotoxicity - Skin irritation - Skin sensitization were conducted. ## Electromagnetic compatibility and electrical safety test - IEC 60601-1 test - IEC 60601-1-11 test - Lithium battery safety test - IEC 60601-1-2 test ## Performance testing - IEC 60601-2-47 test - Disposable ECG electrode test ## Software - Recorder-VSH101 validation - APP-VSHealth validation - Cybersecurity-Cybersecurity management ## HFE/UE ## RF Wireless test {11} VitalSigns ## 10. Conclusion The VitalSigns 1-Lead Holter is substantially equivalent with respect to safety and effectiveness to the legally marketed predicate device for its intended use. Minor differences between the VitalSigns 1-Lead Holter and the predicate device have no effect on safety or effectiveness, as established through various performance tests. Page 8 of 8
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...