Traufix osteosynthesis, osteotomy, and arthrodesis devices
K201510 · Fixier S.A. DE C.V. · HRS · Feb 18, 2022 · Orthopedic
Device Facts
Record ID
K201510
Device Name
Traufix osteosynthesis, osteotomy, and arthrodesis devices
Applicant
Fixier S.A. DE C.V.
Product Code
HRS · Orthopedic
Decision Date
Feb 18, 2022
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3030
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Traufix medical devices are intended for fixation of fractures and osteotomies of various bones including the pelvis, clavicle, scapula, humerus, ulna, radius, femur, tibia, olecranon, and fibula.
Device Story
Traufix devices are metallic bone fixation implants (plates and screws) used for treatment and consolidation of fractures, osteotomies, and joint ossification. Implants are fixed adjacent to bone to provide stabilization. Used in clinical settings by surgeons. Output is physical stabilization of bone segments; affects clinical decision-making by enabling bone healing and structural support. Benefits include restoration of skeletal integrity.
Clinical Evidence
No clinical data. Substantial equivalence demonstrated via non-clinical bench testing, including single-cycle bend testing (ASTM F382), breaking torque testing (ISO 6475), and engineering analysis comparing structural properties (bending stiffness, structural stiffness, and strength) against predicate devices.
Technological Characteristics
Materials: Stainless steel (ASTM F138, ASTM F139) or titanium-alloy (ASTM F136). Components: Various plates and screws for mini, small, and large fragment fixation. Mechanical fixation principle. Sterilization method not specified.
Indications for Use
Indicated for patients requiring fixation of fractures and osteotomies of the pelvis, clavicle, scapula, humerus, ulna, radius, femur, tibia, olecranon, and fibula.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Predicate Devices
AUXEIN BRAND Of Bone Plates and Bone Screws & AUXEIN BRAND Of DCS Plate System AUXEIN brand of Locking Plates and Locking Screws (K141680)
Synthes (USA) Modular Mini Fragment LCP System (K063049)
Synthes (USA) LCP Proxima Humerus Plates, Long (K041860)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the date March 18, 2022. The text is written in a clear, sans-serif font. The date is written in the standard US format, with the month first, followed by the day and year. The text is centered and takes up most of the image.
FDA U.S. FOOD & DRUG
ADMINISTRATION
Fixier, S.A. de C.V. % Aurelia Brownridge Regulatory Affairs Consultant Aurelia Brownridge 11594 Cesped Drive San Diego, California 92124
Re: K201510
Trade/Device Name: Traufix osteosynthesis, osteotomy, and arthrodesis devices Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: Class II Product Code: HRS, HWC
Dear Aurelia Brownridge:
The Food and Drug Administration (FDA) is sending this letter to notify you of an administrative change related to your previous substantial equivalence (SE) determination letter dated February 18, 2022. Specifically, FDA is updating this SE Letter as an administrative correction, as two copies of the SE letter were sent in error along with the Indications for Use statement for K201510, but not the 510(k) Summary.
Please note that the 510(k) submission was not re-reviewed. For questions regarding this letter please contact Shumaya Ali, M.P.H., OHT6: Office of Orthopedic Devices, (301) 796-2356, shumaya.ali@fda.hhs.gov.
Sincerely,
Shumaya Ali -S
Shumaya Ali, MPH Assistant Director DHT6C: Division of Restorative, Repair and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
{1}------------------------------------------------
February 18, 2022
Image /page/1/Picture/1 description: The image shows the logos of the Department of Health & Human Services and the U.S. Food & Drug Administration (FDA). The Department of Health & Human Services logo is on the left and features a stylized depiction of a human figure. The FDA logo is on the right and includes the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text.
Fixier, S.A. de C.V. % Aurelia Brownridge Regulatory Affairs Consultant Aurelia Brownridge 11594 Cesped Drive San Diego, California 92124
Re: K201510
Trade/Device Name: Fixier osteosynthesis, osteotomy, and arthrodesis devices Regulation Number: 21 CFR 888.3030 Regulation Name: Single/Multiple Component Metallic Bone Fixation Appliances And Accessories Regulatory Class: Class II Product Code: HRS, HWC Dated: January 15, 2022 Received: January 20, 2022
Dear Aurelia Brownridge:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE(@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
# Shumava Ali -
Shumaya Ali, MPH Assistant Director DHT6C: Division of Restorative, Repair and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
# Indications for Use
510(k) Number (if known) K201510
Device Name
Traufix osteosynthesis, osteotomy, and arthrodesis devices
#### Indications for Use (Describe)
Traufix medical devices are intended for fixation of fractures and osteotomies of various bones including the pelvis, clavicle, scapula, humerus, ulna, radius, femur, tibia, olecranon, and fibula.
| Type of Use (Select one or both, as applicable) |
|---------------------------------------------------------------------------------------------------------------------------------------|
| <span style="font-size: 10pt;"> <span style="font-family: Wingdings;">☑</span> Prescription Use (Part 21 CFR 801 Subpart D) </span> |
| <span style="font-size: 10pt;"> <span style="font-family: Wingdings;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) </span> |
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW *
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
# 510(k) Summary - K201510
The following 510(k) summary has been prepared pursuant to requirements specified in 21 CFR 807.92.
510(k) Bundle: This submission includes a range of Fixier's products with the same regulation classification and regulation code name.
Date Summary Prepared: February 15, 2022
## Manufacturer and Contact Information:
| Submitter's<br>Name | Submitter's<br>Physical Address | Submitter's<br>Contact Information |
|-------------------------|------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Fixier, S.A. de<br>C.V. | Carretera Doctor Mora a San Miguel<br>de Allende km 3.4, C.P. 37967<br>Comunidad de San Rafael, Doctor<br>Mora, Guanajuato, México | Primary Official Contact:<br>Aurelia Brownridge<br>Regulatory Affairs (Consultant)<br>Telephone: 760-497-4354<br>Secondary Contact:<br>Vianey Mariana Perez Suarez<br>Biological and Pharmaceutical<br>Chemistry<br>Regulatory Affairs Chief |
| | | Telephone: 011-52-419-688-11-91 |
## Device and Classification Information:
| Proprietary Name: | Traufix osteosynthesis, osteotomy, and arthrodesis devices |
|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------|
| Common Name: | Plate, Fixation, Bone (primary)<br>Screw, Fixation, Bone |
| Classification Name: | Single/multiple component metallic bone fixation appliances and<br>accessories (primary)<br>Smooth or threaded metallic bone fixation fastener |
| Regulatory Class: | II |
| Product Codes: | HRS (primary)<br>HWC |
| Regulation Number: | 21 CFR 888.3030 (primary)<br>21 CFR 888.3040 |
{5}------------------------------------------------
Indications for Use: Traufix medical devices are intended for fixation of fractures and osteotomies of various bones including the pelvis, clavicle, scapula, humerus, ulna, radius, femur, tibia, olecranon, and fibula.
Description: Traufix osteosynthesis medical devices are metal implants (stainless steel per ASTM F138, or ASTM F139, or titanium-alloy per ASTM F136) fixed adjacent to the bone for the treatment and consolidation of fractures, osteotomies, and/or joint ossification. The devices include different types and sizes of plates and screws. The product's list is shown below:
| Plate<br>type | Plate<br>code | Plate<br>description | Screw<br>code | Screw description | Surgical<br>technique # | Surgical technique<br>name |
|--------------------|-------------------------------------|-----------------------------------------------------------------|---------------|------------------------------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------------------|
| Mini<br>fragments | 017 | 2.7 DCP Plates | 064 | 2.7mm cortex screw | | DCP plates |
| | 207 | 2.0 DCP Plates | 079 | 2.0mm cortex screw | TQ-005 | |
| | 202<br>&<br>203 | 2.7mm L-plate | 064 | 2.7mm cortex screw | TQ-032 | T and L plates for<br>3.5mm, 2.7mm, and<br>2.0mm screws |
| | 016 | 3.5mm One-<br>third tubular<br>plate | 057 | 3.5mm cortex screw | TQ-004 | 3.5mm One-third<br>tubular plate |
| | | | 058 | 4.0mm cancellous screw<br>partially threaded | | |
| | | | 059 | 4.0mm cancellous screw<br>fully threaded | | |
| Small<br>fragments | 110,<br>111,<br>172,<br>&<br>173 | ALP titanium<br>distal tibia<br>plates TIDIS &<br>TIDIS-III | 112 | 3.5mm titanium cortex<br>screw | | ALP titanium distal<br>tibia plate<br>TIDIS I AND<br>TIDIS III |
| | | | 106 | 3.5mm titanium cortex<br>locking screw | TQ-011 | |
| | | | 107 | 3.5mm titanium<br>cancellous locking<br>screw | | |
| | 129 | ALP titanium<br>proximal<br>humerus plate<br>PROH-LOCK<br>LARGE | 112 | 3.5mm titanium cortex<br>screw | TQ-014 | ALP titanium<br>humerus plate<br>PROH-LOCK and<br>PROH-LOCK<br>LARGE |
| | | | 106 | 3.5mm titanium cortex<br>locking screw | | |
| | | | 107 | 3.5mm titanium<br>cancellous locking<br>screw | | |
| | 144<br>&<br>145 | ALP titanium<br>distal lateral<br>humerus plate<br>DH-LOCK | 112 | 3.5mm titanium cortex<br>screw | TQ-017 | ALP titanium distal<br>lateral humerus<br>plate and ALP<br>titanium<br>Distal medial<br>humerus plate DH-<br>LOCK |
| | | | 106 | 3.5mm titanium cortex<br>locking screw | | |
| | | | 107 | 3.5mm titanium<br>cancellous locking<br>screw | | |
| | | | 170 | 2.7mm titanium cortex<br>locking screw | | |
| | 148,<br>148S,<br>149,<br>&<br>149S. | ALP titanium<br>distal radius<br>plate LIONTER | 154X | 2.5mm titanium cortex<br>screw Torx drive | TQ-018 | ALP titanium distal<br>radius plate |
| | | | 155X | 2.5mm titanium cortex<br>locking screw Torx<br>drive | | |
{6}------------------------------------------------
| Fixier |
|-----------------------------------------------------------|
| Traufix osteosynthesis, osteotomy and arthrodesis devices |
| Plate<br>type | Plate<br>code | Plate<br>description | Screw<br>code | Screw description | Surgical<br>technique # | Surgical technique<br>name |
|--------------------|-----------------|--------------------------------------------------|---------------|----------------------------------------------------------|-------------------------|----------------------------------------------------|
| | 164<br>&<br>165 | ALP titanium<br>distal tibia<br>plates TIDIS-III | 112 | 3.5mm titanium cortex<br>screw | TQ-023 | ALP titanium distal<br>plate TIDIS II |
| | | | 106 | 3.5mm titanium cortex<br>locking screw | | |
| | | | 107 | 3.5mm titanium<br>cancellous locking<br>screw | | |
| | 023 | 4.5mm<br>Reconstruction<br>plates | 056 | 4.5mm cortex screw | TQ-009 | Reconstruction<br>plates |
| | | | 060 | 6.5mm cancellous screw<br>16mm thread | | |
| | | | 061 | 6.5mm cancellous screw<br>32mm thread | | |
| | | | 062 | 6.5mm cancellous screw<br>fully threaded | | |
| Large<br>fragments | 150<br>&<br>151 | ALP titanium<br>proximal femur<br>plate TLP | 126 | 4.5mm titanium cortex<br>screw | TQ-019 | ALP titanium<br>proximal femur<br>plate TLP |
| | | | 108 | 5.0mm titanium cortex<br>locking screw | | |
| | | | 171 | 5.0mm titanium<br>cannulated cortex<br>locking screw | | |
| | | | 109 | 5.5mm titanium<br>cancellous locking<br>screw | | |
| | | | 156 | 7.3mm titanium<br>cannulated cancellous<br>locking screw | | |
| | 152<br>&<br>153 | ALP titanium<br>proximal tibia<br>plate OPTIMUS | 126 | 4.5mm titanium cortex<br>screw | TQ-020 | ALP titanium<br>proximal<br>Tibia plate<br>OPTIMUS |
| | | | 108 | 5.0mm titanium cortex<br>locking screw | | |
| | | | 109 | 5.5mm titanium<br>cancellous locking<br>screw | | |
| Substantial<br>Equivalence: | Traufix osteosynthesis, osteotomy, and arthrodesis devices and<br>predicate devices have the same indications for use, target<br>population, patient contact, materials, and sterilization methods. |
|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| | Traufix subject devices, and predicate devices are intended for<br>fracture fixation and minor differences exist in the physical shape<br>and dimension characteristics of the plates and screws. However,<br>these minor dimensional differences do not raise any new<br>questions of safety or effectiveness. |
| Primary Predicate<br>Device: | AUXEIN BRAND Of Bone Plates and Bone Screws & AUXEIN<br>BRAND Of DCS Plate System AUXEIN brand of Locking Plates<br>and Locking Screws, (K141680) |
{7}------------------------------------------------
| Other Predicate<br>Devices: | -Synthes (USA) Modular Mini Fragment LCP System, (K063049)<br>-Synthes (USA) Medial Distal Tibia Plates, (K001945)<br>-Synthes Variable Angle Locking Compression Plate (VA-LCP),<br>(K071184)<br>-Synthes One-Third Tubular DCL Plate, (K011335)<br>-Synthes 4.5mm LCP Straight Reconstruction Plates, (K051986)<br>-Synthes (USA) LCP Proxima Humerus Plates, Long, (K041860) |
|----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Non-Clinical<br>(Performance Testing): | -Non-clinical testing was performed in the subject devices as<br>follows:<br>-Single cycle bend testing was performed according to ASTM<br>F382.<br>-Breaking torque testing was performed according to ISO 6475.<br>-Engineering analysis was performed to compare the<br>structural properties per ASTM F382 A1 (bending stiffness,<br>bending structural stiffness, and bending strength) of the proximal<br>tibia plate (subject device) and proximal tibia plate (predicate<br>device one).<br>-Engineering analysis and comparison of technology was also<br>provided to compare design and dimensions of the subject and<br>predicate plates and screws. |
| Clinical Testing: | Clinical testing is not a prerequisite, as osteosynthesis, osteotomy,<br>and arthrodesis implants conform to recognized standards and have<br>well established safety and performance characteristics. Therefore,<br>clinical information is not necessary to demonstrate safety and<br>effectiveness or substantial equivalence. |
| Conclusion: | The Traufix osteosynthesis, osteotomy, and arthrodesis devices<br>have been found to be substantially equivalent to the predicate<br>devices. Differences between the subject devices and the predicate<br>devices do not raise new questions of safety or effectiveness. |
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.