K180767 · Life Science Technology, Inc. · FLL · Jan 22, 2019 · General Hospital
Device Facts
Record ID
K180767
Device Name
FEMON Banana Thermometer
Applicant
Life Science Technology, Inc.
Product Code
FLL · General Hospital
Decision Date
Jan 22, 2019
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.2910
Device Class
Class 2
Attributes
Pediatric
Intended Use
The FEMON Banana Thermometer is a battery operated electronic device with intended use of measuring human body temperature. This device is intended for armpit temperature measurement for patients from ages 29 days and older.
Device Story
FEMON Banana Thermometer is a wearable, battery-operated electronic thermometer; consists of a body patch applied directly to the patient's armpit skin. Device measures body temperature and transmits data wirelessly via Bluetooth (2.4G BLE) to a mobile application on iOS or Android smart devices. Intended for home use; allows continuous monitoring. User selects from four measurement interval options (e.g., intensive monitoring every second for 20 seconds, or default 5-second intervals, 30-second, or 60-second intervals) to balance battery life and monitoring needs. Healthcare providers or patients view temperature data on the mobile app interface to track body temperature trends. Benefits include non-invasive, continuous temperature monitoring for patients 29 days and older.
Clinical Evidence
Bench testing only. Performance supported by clinical accuracy testing per ISO 80601-2-56, EMC and electrical safety testing (IEC 60601-1, IEC 60601-1-2), software verification and validation, and biocompatibility testing (cytotoxicity, sensitization, irritation) per ISO 10993.
Technological Characteristics
Wearable patch form factor; 3.0V DC lithium button cell power; Bluetooth 2.4G BLE connectivity. Standards: IEC 60601-1 (safety), IEC 60601-1-2 (EMC), IEC 60601-1-6 (usability), ISO 80601-2-56 (thermometer performance), ISO 10993-1/5/10 (biocompatibility). Measurement range 35-42°C; accuracy ±0.1°C. Software-based data transmission to mobile app.
Indications for Use
Indicated for armpit temperature measurement in patients aged 29 days and older.
Regulatory Classification
Identification
A clinical electronic thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electronic signal amplification, conditioning, and display unit. The transducer may be in a detachable probe with or without a disposable cover.
Special Controls
(1) Device is not a clinical thermometer with telethermographic functions;
(2) Device is not a clinical thermometer with continuous temperature measurement functions; and
(3) Appropriate analysis and testing (such as that outlined in the currently FDA-recognized editions, as appropriate, of ISO 80601-2-56, “Medical electrical equipment—Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement,” or ASTM E1965, “Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature,” or ASTM E1112, “Standard Specification for Electronic Thermometer for Intermittent Determination of Patient Temperature,” or ASTM E1104, “Standard Specification for Clinical Thermometer Probe Covers and Sheaths”) must validate specifications and performance of the device.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains two logos. The logo on the left is the Department of Health & Human Services - USA logo. The logo on the right is the FDA U.S. Food & Drug Administration logo. The FDA logo is in blue.
January 22, 2019
Life Science Technology Inc. % Priscilla Chung Regulatory Affairs Consultant LK Consulting Group USA Inc. 690 Roosevelt Irvine, California 92620
Re: K180767
Trade/Device Name: FEMON Banana Thermometer Regulation Number: 21 CFR 880.2910 Regulation Name: Clinical Electronic Thermometer Regulatory Class: Class II Product Code: FLL Dated: December 19, 2018 Received: December 21, 2018
Dear Priscilla Chung:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmp/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal
{1}------------------------------------------------
statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/CombinationProducts/GuidanceRegulatoryInformation/ucm597488.htm); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely.
# Sapana Patel -S
for Tina Kiang, Ph.D. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K180767
Device Name FEMON Banana Thermometer
#### Indications for Use (Describe)
The FEMON Banana Thermometer is a battery operated electronic device with intended use of measuring human body temperature. This device is intended for armpit temperature measurement from ages 29 days and older.
| Type of Use (Select one or both, as applicable) | |
|-------------------------------------------------|--|
|-------------------------------------------------|--|
Prescription Use (Part 21 CFR 801 Subpart D)
X Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW *
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
# 510(k) Summary
(K180767)
This summary of 510(k) is being submitted in accordance with requirements of 21 CFR Part 807.92.
Date: January 22, 2019
#### 1. 510K Applicant / Submitter:
Life Science Technology Inc. Suite B-1207, Gangseo Hangang Xi Tower, Yangcheon-ro 401, Gangseo-gu, Seoul, South Korea, 07528 Tel: +82-70-8620-8021
#### 2. Submission Contact Person
LK Consulting Group USA, Inc. 690 Roosevelt, Irvine CA 92620 Priscilla Juhee Chung Phone: 714.202.5789 Fax: 714-409-3357 Email: juhee.c@lkconsultinggroup.com
#### 3. Device
- Proprietary Name: FEMON BananaThermometer .
- . Common Name: Electronic Thermometer
- Classification: Class II (21 CFR 880.2910), Clinical Electronic Thermometer .
- Product Code: FLL .
#### 4. Predicate Device
- . Primary Predicate Device: Fever Scout by VivaLink (K162137)
#### 5. Description:
The FEMON Banana Thermometer is a thermometer composed of a body patch to be directly attached to the patient's skin on armpit. The temperature information is then to be retrieved from the patch to the mobile phone application via Bluetooth.
{4}------------------------------------------------
## 8. Indications for Use
The FEMON Banana Thermometer is a battery operated electronic device with intended use of measuring human body temperature. This device is intended for armpit temperature measurement for patients from ages 29 days and older.
## 9. Substantial Equivalence Discussion:
The subject device, FEMON Banana Thermometer, has same intended use as the predicate device, and employs similar technology. The differences in the indications for use statement do not raise any different questions of safety or effectiveness.
The differences in technology do not raise different questions of safety and effectiveness. Like the predicate, the subject device functions to transmit continuous measurements of body temperature wirelessly to a mobile app. The device utilizes an adhesive that was evaluated for biocompatibility.
The technical specifications such as display device, working voltage, signal transmission, and receiver between the subject device and the predicate device are similar. The performance specifications such as measurement and accuracy range are similar as well.
The difference is that the subject device has 4 measurement interval options, whereas, the predicate device has only one option. The interval options of the subject device are offered to save battery life and also to choose intensive monitoring. This difference does not raise different questions in safety and performance because the user can choose the interval option for each situation.
| | Subject Device | Primary Predicate Device |
|----------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device Name | FEMON<br>Banana Thermometer | Fever Scout |
| Manufacturer | LIFE SCIENCE<br>TECHNOLOGY Inc. | VivaLink |
| 510(k) Number | K180767 | K162137 |
| Product Code | FLL | FLL |
| Indications for<br>Use | The FEMON Banana Thermometer<br>is a battery operated electronic<br>device with intended use of<br>measuring human body temperature.<br>This device is intended for armpit<br>temperature measurement for<br>patients from ages 29 days and<br>older. | The wireless Fever Scout<br>Continuous<br>Monitoring thermometer is a<br>noninvasive and re-usable<br>electronic device for home use.<br>This product is intended for non-<br>urgent ambulatory continuous armpit<br>body temperature<br>monitoring from ages 29 days and<br>older. |
| Display Use<br>Specification | iOS device display<br>and Android device<br>display | iOS device display |
| Working Voltage | 3.0V DC | 3.0V DC |
| Battery | 3.0v Lithium Button Cell | MS Lithium Rechargeable Battery<br>3.0V |
| Reusability | Yes | Yes |
| Measurement<br>Range (°C) | 35~ 42°C | 35~ 42°C |
| Accuracy (°C) | ±0.1°C: 35~42°C | ±0.1°C: 37 ~39°C.<br>±0.2°C: 35 ~ 37°C and 39<br>~42°C |
| Temperature<br>Unit | °C or °F | °C or °F |
| Signal<br>Transmission | Wireless 2.4G<br>Bluetooth BLE | Wireless 2.4G<br>Bluetooth BLE |
| Receiver | Wireless 2.4G Bluetooth BLE<br>enabled smart devices running<br>Apple operating system iOS 9+ or<br>Android operating system 4.4+ | Wireless 2.4G Bluetooth BLE<br>enabled smart devices running Apple<br>operating system<br>iPhone 5S+ or newer. |
| Operating<br>Condition | 5~40°C<br>15-90% RH | 10~40°C<br>15-85% RH |
| Anatomical<br>Application | Armpit peel-and-<br>stick<br>contact thermometer<br>sensor | Armpit peel-and-<br>stick<br>contact thermometer<br>sensor |
| Temperature<br>Measurement<br>Interval | • Fever Check option for intensive<br>monitoring: continuous<br>measurement every second for 20<br>secs.<br>• Continuous transmitter measures<br>body temperature every 5<br>seconds (default setting). User can<br>change the setting to 30 seconds<br>or 60 seconds. | Continuous transmitter<br>measures body<br>temperature every 15<br>seconds |
| Standard<br>Conformance | IEC 60601-1,<br>IEC 60601-1-2,<br>IEC 60601-1-6,<br>ISO 80601-2-56,<br>ISO 10993-1,<br>ISO 10993-5,<br>ISO 10993-10 | IEC 60601-1,<br>IEC 60601-1-2,<br>ISO 10993-1,<br>ISO 10993-5,<br>ISO 10993-10 |
{5}------------------------------------------------
{6}------------------------------------------------
## 10. Performance Tests
The following performance testing was included to support a determination of substantial equivalence of the device to the predicate:
- Clinical Accuracy Performance Testing (per ISO80601-2-56) ●
- . The EMC and Electrical Safety Testing (per IEC 60601-1 and IEC 60601-1-2
- Software Verification and Validation Testing in according with FDA Guidance for ● Software in Medical Devices
- Biocompatibility Tests (Cytotoxicity, Sensitization, Irritation) per ISO 10993. ●
The test results of the above tests performed on the subject device supported that it is substantially equivalent to the predicate device.
#### 11. Conclusions:
Based on the information provided in this premarket notification, Life Science Technology Inc. concludes that the FEMON Banana Thermometer is substantially equivalent to the predicate device as described herein in.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.