K131952 · Corin USA · LZO · Dec 16, 2013 · Orthopedic
Device Facts
Record ID
K131952
Device Name
CORIN METAFIX HIP STEM
Applicant
Corin USA
Product Code
LZO · Orthopedic
Decision Date
Dec 16, 2013
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3353
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The indications for the Corin MetaFix Hip Stem as a total hip arthroplasty and, when used in combination with Corin hemi-arthroplasty femoral heads, as a hemi-arthroplasty, include: - Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis . - . Rheumatoid arthritis - Correction of functional deformity - Treatment of non-union, femoral neck and trochanteric fractures of the proximal femur . - Developmental dysplasia of the hip (DDH) or congenital dysplasia of the hip (CDI-I) . The Corin MetaFix Hip Stem is intended for cementless use only.
Device Story
Corin MetaFix Hip Stem is a titanium alloy femoral implant for total or hemi-hip arthroplasty; features 12/14 tapered male trunnion for modular femoral head assembly; plasma-sprayed hydroxyapatite coating. Device is implanted by orthopedic surgeons in clinical/OR settings. Modification adds extra-long offset options for CoCrMo and BIOLOX delta ceramic femoral heads to accommodate patient anatomy. Stem provides structural support for hip joint replacement; modular heads allow surgeon to optimize joint biomechanics and stability. Benefits include restoration of hip function and pain relief in patients with degenerative or traumatic hip conditions.
Clinical Evidence
No clinical data. Substantial equivalence determined via non-clinical comparison of compatible components with predicate devices.
Technological Characteristics
Titanium alloy (TiAlV) femoral stem per ASTM F136-12a; plasma-sprayed hydroxyapatite coating per ASTM F1185-03(2009). Modular CoCrMo or BIOLOX delta ceramic femoral heads. 12/14 tapered trunnion connection. Cementless fixation.
Indications for Use
Indicated for total hip arthroplasty or hemi-arthroplasty in patients with non-inflammatory degenerative joint disease (osteoarthritis, avascular necrosis), rheumatoid arthritis, functional deformity, non-union, femoral neck/trochanteric fractures, or developmental/congenital hip dysplasia. Indicated for cementless use only.
Regulatory Classification
Identification
A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A12 03 ) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement.
Corin Trinity Acetabular System with XL Heads (K130343)
Submission Summary (Full Text)
{0}------------------------------------------------
DEC 16 2013
#### K131952
## 3. 510(K) SUMMARY 1. Applicant/Sponsor: Corin USA 5670 W. Cypress Street Suite C Tampa, Florida 33607 Establishment Registration No.:1056629 Contact Person: Lucinda Gerber 2. Regulatory Affairs Associate Corin USA 813-977-4469 lucinda.gerber@coringroup.com Kathy Trier VP US Regulatory and Global Clinical Affairs Corin USA 813-977-4469 kathy.trier@coringroup.com 3. Date: June 26, 2013 Corin MetaFix I-Iip Stem 4. Proprietary Name: Common Name: Hip Prosthesis 5. 6. Product Codes: LZO, KWL, KWY, MEH, OQI, 7. Classification Name: . Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis (21CFR 888.3390) . Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis (21CFR 888.3360) Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented .
prosthesis (21CFR 888.3353)
{1}------------------------------------------------
#### K131952
#### 8. Legally Matketed Devices to which Substantial Equivalence is claimed:
- Corin MetaFix Hip Stem (K082525) .
- Corin MetaFix size 1 (K121439) .
- Corin MetaFix Hip Stem with Hemi-Arthroplasty (K120362) ●
- Corin MetaFix Hip Stem (K130634) ●
- . Corin Trinity Acetabular System with XL Heads (K130343)
#### 9. Device Description:
The Corin MetaFix Hip Stem is a titanium femoral hip stem featuring a 12/14 tapered male trunnion for assembly with modular femoral head components. The stem is manufactured from Titanium (TiAl, V.) alloy for surgical implant applications, conforming to ASTM F136-12a and is coated with plasma sprayed hydroxyapatite conforming to ASTM F1185-03(2009). The Corin MetaFix Hip Stem is available in 10 sizes marked 1 through 10. With size 2 to 10 available in three offsets, including Standard (1359), Lateralized, (1359), and Standard (125°) and size 1 available in two offsets Standard (135°), Lateralized (135°). The Corin MetaFix Hip Stems were originally cleared in K082525 & K121439 and indications and contraindications of hemi arthroplasty and compatible components were added in K120362 & K130634.
Modular CoCrMo Femoral Heads are available in a diameter of 28mm with -3.5mm (short), 0.0mm (standard) and, +3.5mm (long) offsets and diameter of 32mm, 36mm and 40mm heads with offsets of -4mm (short), 0mm (standard) and +4mm (long) as previously cleared in K093472 and K110087 submissions. The 32mm with +7mm offset (extra-long), and the 36mm and 40mm with +8mm offset (extra-long), were added to the range of heads available in K130343.
Modular BIOLOX delta™ Ceramic Femoral Heads are available in a diameter of 28mm with -3.5mm (short), 0mm (standard) and, +3.5mm (long) offsets and diameters of 32mm, 36mm and 40mm heads with offsets of -4mm (short), 0mm (standard) +4mm (long) as previously cleared in K103120 and K110087 submissions. The 32mm with +7mm offset (extra-long), and the 36mm and 40mm with +8mm offset (extra-long), were added to the range of heads available in K130343.
The Corin MetaFix Hip Stern was originally cleared in K082525, K121439, K120362 and K130634 and as cleared, compauble with short, standard and long offsets modular femoral heads. The purpose of this submission is to modify the labeling for the Corin MeraFix Hip Stem to include an additional size of the compatible femoral heads. The addition is for three offsets in the CoCrMo and Ceramic extra-long heads, 32mm (+7mm), 36mm (+8mm) and 40mm (+8mm).
{2}------------------------------------------------
#### 10. Intended Use / Indications:
The indications for the Corin MetaFix Hip Stem as a total hip arthroplasty and, when used in combination with Corin hemi-arthroplasty femoral heads, as a hemi-arthroplasty, include:
- Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis .
- . Rheumatoid arthritis
- Correction of functional deformity �
- Treatment of non-union, femoral neck and trochanteric fractures of the proximal femur .
- Developmental dysplasia of the hip (DDH) or congenital dysplasia of the hip (CDI-I) .
The Corin MetaFix Hip Stem is intended for cementless use only.
#### 11. Summary of Technologies/Substantial Equivalence:
MetaFix Stems, subject of this submission, are identical to the predicate devices. This submission adds compatible modular femoral heads in an extra-long offset and is submitted for a modification of labeling. The additional compatible components of the Corin Metalix. Hip Sten, subject device, are identical to predicate Trinity Acetabular System with XL Heads (K1303-13). compatible components, in terms of materials, intended use and indications and similar in design. Based on these similarities, Corin believes the MetaFix Hip Stems, subject of this submission that they are substantially equivalent to the predicate devices.
#### 12. Non-Clinical Testing:
Non-clinical testing conducted to demonstrate substantial equivalence includes a comparison of compatible components with the predicate devices.
#### 13. Clinical Testing:
Clinical testing was not necessary to determine substantial equivalence between the additional compatible components of the Corin MetaFix Hip Stem and the predicate device.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is an abstract symbol resembling an eagle or bird in flight, composed of curved lines. The overall design is simple and monochromatic.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
December 16, 2013
Corin USA Lucinda Gerber, BA (Hons) Regulatory Affairs Associate 5670 West Cypress Street, Suite C Tampa, Florida 33607
Re: K131952 Trade/Device Name: Corin MetaFix Hip Stem Regulation Number: 21 CFR 888.3353 Regulation Name: Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis Regulatory Class: Class II Product Code: LZO, KWL, KWY, MEH, OQI Dated: November 7, 2013 Received: November 8, 2013
Dear Ms. Gerber:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{4}------------------------------------------------
### ······· Page 2-Lucinda Gerber, BA (Hons)
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 53.1-542 of the Act): 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note, the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industrv/default.htm.
Sincerely yours,
# Ronald BAJean -S for
- · Mark N. Melkerson Director Division of Orthopedic Devices
- Office of Device Evaluation Center for Devices and
- Radiological Health
Enclosure
{5}------------------------------------------------
#### INDICATIONS FOR USE 2.
510(k) Number (if known): K131952
Device Name: Corin Metafix Hip Stem
Indications for Use:
" ﻧﺴﺒﺔ ﺍﻟﺘﻬﺪﻳﺔ ﺍﻟﻤﻠﻜﺔ
The indications for the Corin Metafix Hip Stem as a total hip arthroplasty and, when used in combination with Corin hemi-atthroplasty femoral heads, as a hemi-arthroplasty, include:
- . Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis
- Rheumatoid arthritis .
- . Correction of functional deformity
- . Treatment of non-union, femoral neck and trochanteric fractures of the proximal femur
Developmental dysplasia of the hip (DDH) and congenital dysplasia of the hip � (CDH)
The Corin Metafix Hip Stem is indicated for cementless use only.
Prescription Use X AND/OR (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
### (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
# Elizabeth L. Frank -S
Page 1 of 1
Division of Orthopedic Devices
Page 6 of 210
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.