IMPAX VOLUME VIEWING

K111638 · Agfa Healthcare N.V. · LLZ · Jun 24, 2011 · Radiology

Device Facts

Record IDK111638
Device NameIMPAX VOLUME VIEWING
ApplicantAgfa Healthcare N.V.
Product CodeLLZ · Radiology
Decision DateJun 24, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.2050
Device ClassClass 2
AttributesSoftware as a Medical Device, 3rd-Party Reviewed

Intended Use

Impax Volume Viewing software is a visualization package for PACS workstations. It is intended to support radiographer, medical imaging technician, radiologist and referring physician in the reading, analysis and diagnosis of DICOM compliant volumetric medical datasets. The software is a general purpose digital medical image processing tool, with optional functionality to facilitate visualization and measurement of vessel features. Other optional functionality is intended for the registration of anatomical (CT) on functional volumerric image data (MR) to facilitate the comparison of various lesions. Volume and distance measurements are intended for evaluation and quantification of tumor measurements, and other analysis and evaluation of both hard and soft tissues. The software also supports interactive segmentation of a region of interest (ROI).

Device Story

Impax Volume Viewing is a software accessory for PACS workstations used by radiologists, technicians, and physicians. It inputs DICOM-compliant volumetric medical datasets (e.g., CT, MR). The software provides tools for 3D volume rendering, multi-planar reconstruction (MPR), curved planar reformation (CPR), and intensity projections (MIP/MiniP/AveIP). It enables automatic or manual registration/fusion of multi-modality datasets, interactive segmentation of regions of interest (ROI), and vessel analysis. Outputs include visualized images, color maps, subtraction views, and quantitative measurements (volume/distance) for tumor evaluation and tissue analysis. Clinicians use these outputs to assist in reading, analysis, and diagnosis of medical images. The device facilitates clinical decision-making by providing enhanced visualization and quantification of anatomical and functional data.

Clinical Evidence

No clinical trials were performed. Substantial equivalence is supported by verification and validation testing confirming the device meets performance, measurement, and usability requirements.

Technological Characteristics

Software accessory for PACS. Features: 3D volume rendering, MPR, CPR, MIP, fusion/subtraction, vessel segmentation, and measurement tools. Connectivity: DICOM-compliant. Standards: EN12435:2006, ISO 14971:2007, ISO 13485:2003. Operates on PACS workstations.

Indications for Use

Indicated for use by radiographers, medical imaging technicians, radiologists, and referring physicians to read, analyze, and diagnose DICOM-compliant volumetric medical datasets. Supports visualization/measurement of vessel features, registration of anatomical (CT) and functional (MR) data for lesion comparison, tumor quantification, and soft/hard tissue analysis.

Regulatory Classification

Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K 111638 ## JUN 2 4 2011 ## 510(K) SUMMARY: IMPAX VOLUME VIEWING Common/Classification Name: Picture Archiving and Communications System 21 CFR 892.2050 Proprietary Name: Impax Volume Viewing Agfa HealthCare N.V. Septestraat 27 B-2640 Mortsel Belgium Contact: Koen Cobbaert, Prepared: May 6, 2011 Telephone: 32 3 444 7539 #### LEGALLY MARKETED PREDICATE DEVICES A. This is a 510(k) for Agfa's Impax Volume Viewing software, which is an accessory to its Impax picture archiving and communications systems. It is substantially equivalent to Agfa's Registration and Fusion software (K080013) in the majority of its functionality and to the Voxar 3D Enterprise with ColonMetrix and PET/CT Perfusion (K070831) with respect to its vessel viewing functionality. #### B. DEVICE DESCRIPTION The new device is similar to the predicate devices. All are PACS system accessories that allow the user to view and manipulate three dimensional image data sets. Principles of operation and technological characteristics of the new and predicate devices are the same. The intended uses of the new and predicate devices are also the same. #### c. INTENDED USE Impax Volume Viewing software is a visualization package for PACS workstations. It is intended to support radiographer, medical imaging technician, radiologist and referring physician in the reading, analysis and diagnosis of DICOM compliant volumetric medical datasets. The software is a general purpose digital medical image processing tool, with optional functionality to facilitate visualization and measurement of vessel features. Other optional functionality is intended for the registration of anatomical (CT) on functional volumerric image data (MR) to facilitate the comparison of various lesions. Volume and distance measurements are intended for evaluation and quantification of tumor measurements, and other analysis and evaluation of both hard and soft tissues. The software also supports interactive segmentation of a region of interest (ROI). #### D. SUBSTANTIAL EQUIVALENCE SUMMARY Agfa's Impax Volume Viewing has an Indications For Use Statement largely similar to the statements for the two predicate. Intended uses are the same. As software accessories to PACS systems, the predicate and new devices have the same technological characteristics. Software is used to identify characteristic patterns within 3D image data which the user can then view and manipulate. Descriptive characteristics and performance data are adequate to ensure equivalence. Differences in the new device and the predicates do not alter their intended therapeutic/diagnostic effects. {1}------------------------------------------------ # Agfa HealthCare NV Premarket Notification: Impax Volume Viewing l | PRODUCT COMPARISON TABLE | | | | |----------------------------------------------------|-----------------------------------------|---------------------------------------------------------|----------------------------------------------------------------------------------------| | | Impax<br>Volume Viewing<br>(NEW DEVICE) | Impax<br>Registration and Fusion<br>(PREDICATE K080013) | Voxar 3D Enterprise<br>with ColonMetrix and<br>PET/CT Perfusion<br>(PREDICATE K070831) | | 3D Volume rendering | √ | √ | √ | | MPR CPR | √ | MPR | √ | | MIP MiniP AveIP | √ | MIP | √ | | Fusion and subtraction views | √ | √ | - | | Can load and register two data sets for comparison | √ | √ | - | | Multi-modality (CT and MR) image registration | √ | √ | - | | Vessel analysis | √ | - | √ | | Manual slice by slice volume-of-interest | √ | √ | - | | DICOM and AVI movie generation | √ | √ | √ | | Reformat to a new dataset | √ | √ | √ | | Color maps | √ | √ | √ | | Annotations and measurements | √ | √ | √ | | Automatic table top removal | √ | √ | √ | | User Interface | Impax | Impax | Voxar | · 5 - 4 · {2}------------------------------------------------ #### TECHNOLOGICAL CHARACTERISTICS C. Impax Volume Viewing is a software accessory to Agfa's Impax Picture Archiving and Communications system. It is a tool for conveniently viewing and manipulating cross-sectional image series' for display in any orientation and slice thickness. A second series can be registered or fused to the first automatically, manually or with user defined landmarks. Segmentation of blood vessels and airfilled structures facilitate the visualization of vessel features. Color maps, subtraction views, multiple screen layouts and tools for measurement, calculations and annotations are provided. #### F. TESTING Verification and validation testing confirm the device meets performance, measurement and usability requirements. No clinical trials were performed in the development of the device. The new device and Agfa's management systems conform to the following standards: - EN12435:2006 Health Informatics Expression of Results of Measurements in Health ● Sciences - . ISO 14971:2007 - Application of Risk Management to Medical Devices - ISO 13485:2003 Medical Devices Quality Management Systems Requirements For . Regulatory Purposes #### CONCLUSIONS G. This 510(k) has demonstrated Substantial Equivalence as defined and understood in the Federal Food Drug and Cosmetic Act and various guidance documents issued by the Center for Devices and Radiological Health. {3}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the logo of the U.S. Department of Health and Human Services. The logo consists of a stylized human figure with three arms, enclosed in a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" around it. The text "DEPARTMENT" is written in bold, sans-serif font to the right of the logo. ## DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002 AGFA Healthcare N.V. % Mr. Mark Job Responsible Third Party Official Regulatory Technology Services LLC 1394 25th Street NW BUFFALO NY 55313 AUG 2 3 2013 Re: K111638 Trade/Device Name: Impax Volume Viewing Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: June 10, 2011 Received: June 13, 2011 Dear Mr. Job: This letter corrects our substantially equivalent letter of June 24, 2011. We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The I va may a controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must or mr) 2 vith all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of {4}------------------------------------------------ medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely Yours, Janine M. Morris Acting Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ## Indications for Use 510(k) Number (if known): Device Name: Impax Volume Viewing ### Indications for Use: Impax Volume Viewing is a visualization package for PACS workstations. It is intended to support radiographer, medical imaging technician, radiologist and referring physician in the reading, analysis and diagnosis of DICOM compliant volumetric medical datasets. The software is intended as a general purpose digital medical image processing tool, with optionality to facilitate visualization and measurement of vessel features. Other optional functionality is intended for the registration of anatomical (CT) on functional volumetric image data (MR) to facilitate the comparison of various lesions. Volume and distance measurements are intended for evaluation and quantification of tumor measurements, and other analysis and evaluation of both hard and soft tissues. The software also supports interactive segmentation of a region of interest (ROI). Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) Mary S Patil Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety 510(k) K111638 Page 1 of FDA CDRH DMC
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%