AXSOS LOCKED PLATING 4.0MM LOCKING INSERTS

K110176 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · HRS · Feb 15, 2011 · Orthopedic

Device Facts

Record IDK110176
Device NameAXSOS LOCKED PLATING 4.0MM LOCKING INSERTS
ApplicantHowmedica Osteonics Corp., Dba Stryker Orthopaedics
Product CodeHRS · Orthopedic
Decision DateFeb 15, 2011
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 888.3030
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The AxSOS Locked Plating System in the Stryker Locked Plating System is intended for use in long bone fracture fixation. The AxSOS Locked Plating System is indicated for fixation of long bone fractures including fractures of the distal radius, the proximal humerus, the distal tibia, proximal tibia, and the distal femur.

Device Story

AxSOS Locked Plating System 4mm Locking Inserts are orthopedic fixation components used in long bone fracture repair. These inserts are integrated into the existing AxSOS plating system to provide secure bone fixation. The device is used by surgeons in clinical or operating room settings. The inserts are manufactured from stainless steel and are designed to improve manufacturability while maintaining the mechanical performance of the predicate system. The system functions by providing stable internal fixation for fractures, aiding in bone healing. The device is intended for prescription use only.

Clinical Evidence

No clinical data provided; substantial equivalence is supported by non-clinical bench testing including insertion force, screw insertion, push out, torsion, bending, and fatigue.

Technological Characteristics

Materials: Stainless steel per ASTM F138 and ASTM F139. Components: 4mm locking inserts for bone plates. Operational principle: Mechanical bone fixation via locking mechanism. Design: Line extension of existing AxSOS system components.

Indications for Use

Indicated for fixation of long bone fractures, specifically distal radius, proximal humerus, distal tibia, proximal tibia, and distal femur fractures.

Regulatory Classification

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K110176 * 1/d AxSOSE Locked Plating System I.Ine Extension of 4mm Locklug Inserts Special 510(k) FEB 15 201 ### 510(k) Summary of Safety and Effectivencss: # AxSOS® Locked Plating System Line Extension of 4mm Locking Inserts Sponsor Howmedica Osteonics Corp. 325 Corporate Drive Mahwalı, NJ 07430 Contact Person Anthony Dennis Specialist, Regulatory Affairs Howmedica Osteonics Corp. 325 Corporate Drive Mahwalı, NJ 07430 Phone: (201) 831-5804 | Date Prepared: | January 19, 2011 | |----------------------|----------------------------------------------------------------------------------------------------| | Proprietary Name: | AxSOS® Locked Plating System Line Extension of 4mm Locking<br>Inserts | | Common Name: | Bone plates and screws | | Classification Name: | 21 CFR §888.3030<br>Single/multiple component metallic bone fixation appliances and<br>accessories | | Classification Name: | 21 CFR §888.3040<br>Smooth or Threaded metallic bone fixation fastener | Legally Marketed Device to Which Substantial Equivalence is Claimed: Howmedica Osteonics Stryker Locked Plating System: K050512 Device Description: This Special 510(k) submission is intended to address modifications to the Device Desertifican. This Openal 910(x) backing Insert is heing modified as part of a line {1}------------------------------------------------ K110176 #2/d #### AxSOS Locked Plating System Line Extension of 4mm Locking Inserts Special 510(k) extension of the AxSOS® Locked Plating System. The AxSOS® Locked Plating System contains 4mm Locking Inserts to which changes are being made to improve manufacturability. The locking inserts are made from stainless steel per ASTM F138 and ASTM F139. The AxSOS® Locked Plating 4.0mm Locking Inserts have similar or identical and material properties to the predicate 4.0mm Locking Inserts determined substantially equivalent via 510(k) K050512. Intended Use: The AxSOS® Locked Plating System Line Extension of 4mm Locking Insert modifications do not alter the intended use of the predicate systems as cleared in their respective premarket notifications. The indications for use for the subject plates are provided below. #### Indications: The AxSOS Locked Plating System in the Stryker Locked Plating System is intended for use in long bone fracture fixation. The AxSOS Locked Plating System is indicated for fixation of long bone fractures including fractures of the distal radius, the proximal humerus, the distal tibia, proximal tibia, and the distal femur. Summary of Technologies: The technological characteristics (material, design, sizes, and operational principles) of the AxSOS® Locked Plating 4.0mm Locking Inserts are similar or identical to the predicate device, K050512. Non-Clinical Testing: Non-clinical laboratory testing was performed to determine substantial equivalence. The following mechanical/functional testing was performed: insertion force, screw insertion, push out, torsion, bending, and fatigue. The testing demonstrated that the AxSOS® Locked Plating 4.0mm Locking Inserts met performance requirements and are as safe and effective as their predicates. Clinical Testing: None provided as a basis for substantial equivalence #### Conclusion: The AxSOS® Locked Plating 4.0mm Locking Inserts is substantially equivalent to the predicate devices identified in this pre-market notification. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services USA. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is a stylized symbol that resembles an abstract human figure with three flowing lines extending from its body. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 Howmedica Osteonics Corp. % Mr. Anthony Dennis 325 Corporate Drive Mahwah, New Jersey 07430 FEB 15 201 Re: K110176 Trade/Device Name: AxSOS® Locked Plating System Line Extension of 4mm Locking Inserts Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: Class II Product Code: HRS, HWC Dated: January 20, 2011 Received: January 21, 2011 Dear Mr. Dennis: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 898. In addition, FDA may , publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 - Mr. Anthony Dennis Please be advised that FDA 's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, A.S. B. Rh for Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health ### Enclosure {4}------------------------------------------------ ## Indications for Use ### 510(k) Number (if known): K | | Ol 76 Device Name: AxSOS® Locked Plating System Line Extension of 4mm Locking Inserts Indications For Use: The AxSOS Locked Plating System in the Stryker Locked Plaing System are intended for use in I The AxSOS Econod Plating Official in the Stystem is indicated for firstion of long long oone fracture fractures of the distal radius, the proximal humerus, the distal tibia, proximal tibia, and the distal femur. Prescription Use _____________________________________________________________________________________________________________________________________________________________ AND/OR Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________ (Part 21 CFR 801 Subpart D) . (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1 for M. Melkerson (Division Sign-Off) Division of Surgical Orthopedic, and Restorative Devices 510(k) Number K110776
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...