LOCKING BONE SCREW MODEL HCQ04, HCZ04

K100721 · Changzhou Orthmar Medical Instrument Co., Ltd. · HWC · Nov 23, 2010 · Orthopedic

Device Facts

Record IDK100721
Device NameLOCKING BONE SCREW MODEL HCQ04, HCZ04
ApplicantChangzhou Orthmar Medical Instrument Co., Ltd.
Product CodeHWC · Orthopedic
Decision DateNov 23, 2010
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Intended Use

Locking Bone Screw is indicated for bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device.

Device Story

Locking Bone Screw is a metallic bone fixation fastener used for bone reconstruction, osteotomy, arthrodesis, joint fusion, and fracture repair. The device is implanted by a surgeon to provide mechanical stabilization of bone segments. It is intended for use in conjunction with the Orthmed Locking Compressing Bone Plate. The screw acts as a mechanical fastener to secure bone fragments or attach plates to bone, facilitating healing through rigid fixation. It is used in clinical settings by orthopedic surgeons.

Clinical Evidence

Bench testing only. Performance verified per ASTM F543-07 (Standard Specification and Test Methods for Metallic Medical Bone Screws) to confirm design specifications and substantial equivalence to the predicate.

Technological Characteristics

Material: Titanium Alloy (6Al-4V ELI) per ASTM F136-08e1. Dimensions: Diameters 3.5mm, 5.0mm, 6.5mm; lengths 10-120mm. Head types: Normal, Flat, Tapered. Mechanical fixation principle. No software or energy source.

Indications for Use

Indicated for patients requiring bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, or fracture fixation, using screws sized appropriately for the specific bone.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Exhibit #2 510(k) Summary for K100721 NOV 2 3 2010 ## Exhibit #2 510(k) Summary This 510(k) Summary of 510(k) safety and effectiveness information is being submitted in accordance with requirements of SMDA 1990 and 21 CFR 807.92. The Assigned 510(k) Number: _K100721 - Date of Prepared: 12Nov 2010 1. #### Proposed Device Identification 2. Trade/ Proprietary Name:Locking Bone Screw Common Name:Smooth or threaded metallic bone fixation fastener Classification Name:Screw, fixation, bone Device Class: Il Product Code:HWC Regulation Number: 21 CFR 888.3040 Intended Use: I wone Screw isindicated for bone reconstruction, osteotomy, arthrodesis, joint fusion,fracture repair, and fracture fixation of bones appropriate for the size of the device. #### Sponsor Information 3. Establishment Registration Number: 3005597716 Changzhou Orthmed Medical Instrument Co.,Ltd No.177, Qinling Road, New Zone, Changzhou, Jiangsu, China, 213022 Phone: +86-519-85123770-8055 .Fax:+86-519-85123776 ### Submission Correspondent Ms. Diana Hong, Mr. Lee Fu Shanghai Mid-Link Business Consulting Co., Ltd Suite 5D, No.19, Lane 999, Zhongshan No.2 Road(S) Shanghai, 20030, China Tcl: +86-21-64264467 Fax: 240-238-7587 Email: Diana.hong@mid-link.net loR2 {1}------------------------------------------------ #### Predicate Device Identification 4. Merete 3.5mm Locking Screws as cleared under K081513. #### ડ. Device Description The proposed device, Locking Bone Screw, is made of Titanium Alloy (6Al-4V ELI) that meetsASTM F136 - 08e1 Standard Specification for Wrought Titanium-6 Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401) which is intended to be used with Orthmed Locking Compressing Bone Plate for bonc reconstruction,osteotomy, arthrodesis, joint fusion,fracture repair, and fracture fixation of bones appropriate for the size of the device. | Model Name | HCQ04<br>(Normal Head) | HC5Q04<br>(Normal Head/<br>Flat Head) | HCQ04<br>(Normal Head) | HCZ04<br>(Tapered Head) | |---------------|------------------------|---------------------------------------|------------------------|-------------------------| | Diameter (mm) | 3.5 | 5.0 | 6.5 | 5.0 | | Length(mm) | 10~65<br>every 1mm | 10~120<br>every 1mm | 20~120<br>every 1mm | 18~85<br>every 1mm | Table 1 Specifications #### Substantially Equivalence 6. Both the proposed and predicate device has same classification, similar intended use. Both of them were made of Titanium Alloy (6Al-4V ELI) that meets ASTM F136 - 08e1. The performance test was performed on both, the result demonstrated that they have similar performance. Therefore, the proposed device, Locking Bone Screw, is determined to be Substantially Equivalent (SE) to the predicate device, Merete 3.5mm Locking Screws as cleared under K081513. #### 7. Non-Clinical Test Conclusion Bench tests were conducted to verify that the proposed device met all design specifications as was Substantially Equivalent (SE) to the predicate device. The tests were performed per the following standards: ASTM F543-07, Standard Specification and Test Methods for Metallic Medical BoneScrews. 100 {2}------------------------------------------------ ## DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States of America. The seal features a stylized eagle with three lines representing its body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the eagle. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MID 20993-0002 Changzhou Orthmed Medical Instrument Co., Ltd. % Shanghai Midlink Business Consulting Co., Ltd. Ms. Diane Hong Suite 5D, No. 19, Lane 999 Zhongshan No.2 Road (S) Shanghai, China 20030 NOV 2 3 2013 Re: K100721 Trade/Device Name: Locking Bone Screw Model HCO04. HCZ04 Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth or threaded metallic bone fixation fastener Regulatory Class: Class II Product Code: HWC Dated: November 12, 2010 Received: November 15, 2010 Dear Ms. Hong: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device cran he found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act {3}------------------------------------------------ ## Page 2 - Ms. Diane Hong or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely vours. Barbara Buchmu Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Indication for Use K10072 510(k) Number: NOV 2 3 2010 - CALL - CALL - CALL - COMMER - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CALL - CA Device Name: Locking Bone Screw # Indications for Use: Locking Bone Screw is indicated for bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Prescription Use V (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Smata for nym (Division Signa) ision Sig vision of Surgica! Orthopedic, and Restorative Devices 510(k) Number K100721
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%